Wis. Admin. Code SPS § SPS 363.0202

Current through May 28, 2024
Section SPS 363.0202 - General definitions
(1) ADDITIONS. This is a department definition for this chapter in addition to the definitions in IECC section C202: "Effective aperture" or "EA" means for windows, the visible light transmittance times the window wall ratio per wall; and for sky lights, the well efficiency times the visible light transmittance times the sky light area times 0.85 divided by the gross exterior roof area.
(2) SUBSTITUTIONS. Substitute the following for the corresponding definitions listed in IECC section C202:
(a) "Approved" has the meaning given in s. SPS 362.0202(2) (a).
(b) "Daylight responsive control" means a device or system that provides the automatic control of lamps and luminaires located in daylight zone only or a manual control of lamps or luminaires located in daylight zone only in such manner that at least 50% of the lamps are controlled in a reasonably uniform illumination pattern per IECC section C405.2.2.2, with the capability for the lamps to be operated at 100% or 0% of their design lighting capability.

Wis. Admin. Code Department of Safety and Professional Services § SPS 363.0202

CR 06-120: cr. Register February 2008 No. 626, eff. 3-1-08; correction in (2) made under s. 13.92(4) (b) 7, Stats., Register August 2011 No. 668; correction in (2) made under s. 13.92(4) (b) 7, Stats., Register December 2011 No. 672.
Amended by, CR 16-094: am. (1), renum. (2) to (2) (intro.) and am., cr. (2) (a), (b), Register April 2018 No. 748, eff. 5/1/2018