Wis. Admin. Code Department of Safety and Professional Services SPS 362.1603

Current through October 28, 2024
Section SPS 362.1603 - Roof snow load

Substitute the following wording for the requirements in IBC section 1603.1.3: The ground snow load, Pg, shall be indicated. In areas where the ground snow load, Pg, exceeds 10 pounds per square foot, the following additional information shall also be provided, regardless of whether snow loads govern the design of the roof:

(1) Flat-roof snow load, Pf
(2) Snow exposure factor, Ce.
(3) Snow load importance factor, I.
(4) Thermal factor, Ct.
(5) Any sloped-roof snow load, Ps.
(6) Any unbalanced, drift or sliding snow loads.

Wis. Admin. Code Department of Safety and Professional Services SPS 362.1603

CR 00-179: cr. Register December 2001 No. 552, eff. 7-1-02; CR 04-016: renum. (1) and (2) to be (3) and (4), cr. (1) and (2) Register December 2004 No. 588, eff. 1-1-05; CR 06-120: renum. (1) to (4) to be (2) and (4) to (6), cr. (1) and (3) Register February 2008 No. 626. eff. 3-1-08; CR 10-103: r. (title), (1), (3), (4), (6), renum. (2) to be Comm 62.1603, (5) to be Comm 62.0400 (6) Register August 2011 No. 668, eff. 9-1-11.