Wis. Admin. Code Department of Safety and Professional Services SPS 376.06

Current through September 30, 2024
Section SPS 376.06 - Exit doors
(1) Every door which serves as the exit from a stairway shall be not more than 20 feet distant from the stairway unless the passageway from the stairway to the door is enclosed with not less than one-hour fire-resistive partitions and fire-resistive doors (ss. SPS 375.08 to 375.09). Every such door, and also every door which serves as an exit for more than 25 persons shall be a standard exit door as described in s. SPS 375.24.
(2) Exit lights and signs bearing the word EXIT or OUT in plain letters at least 5 inches in height shall be provided over every exit doorway from each floor except the principal entrance on the first floor. Exit lights and signs shall be installed as required by s. SPS 375.24.

Wis. Admin. Code Department of Safety and Professional Services SPS 376.06

1-2-56; renum. and am., Register, September, 1974, No. 225, eff. 10-1-74; corrections made under s. 13.93(2m) (b) 7, Stats., Register, June, 1995, No. 474; correction in (1), (2) made under s. 13.92(4) (b) 7, Stats., Register December 2011 No. 672.