Wis. Admin. Code Department of Safety and Professional Services SPS 375.14

Current through August 26, 2024
Section SPS 375.14 - Exits to fire escapes

Every fire escape shall be accessible from a public passageway or shall be directly accessible from each occupied room. Each exit to a "B" type fire escape shall be a standard exit door (s. SPS 375.24) at least 3 feet 4 inches in width, and the door sill shall be flush with the floor inside. Each exit to an "A" type fire escape shall be a standard exit door at least 2 feet 6 inches in width and the door sill shall be not more than 8 inches above the inside floor level, unless a stair leads from the floor to the sill, or windows may be used in place of such door if approved by the department.

Wis. Admin. Code Department of Safety and Professional Services SPS 375.14

1-2-56; renum. and am., Register, September, 1974, No. 225, eff. 10-1-74; correction made under s. 13.93(2m) (b) 7, Stats., Register, June, 1995, No. 474; correction made under s. 13.92(4) (b) 7, Stats., Register December 2011 No. 672.