Except as provided in 40 CFR 125.30 to 125.32, any existing point source subject to this subchapter shall achieve the following BPT effluent limitations:
GALVANIZED BASIS MATERIAL SUBCATEGORY | ||||
BPT Effluent Limitations | ||||
Maximum for any 1 day | Maximum for monthly average | |||
Pollutant or pollutant property | mg/m2 (pounds per 1 million ft2) of area processed | |||
Chromium | 1.10 | (0.23) | 0.45 | (0.091) |
Copper | 4.96 | (1.02) | 2.61 | (0.54) |
Cyanide | 0.76 | (0.16) | 0.32 | (0.064) |
Zinc | 3.47 | (0.71) | 1.46 | (0.30) |
Iron | 3.21 | (0.66) | 1.65 | (0.34) |
Oil and grease | 52.2 | (10.7) | 31.3 | (6.42) |
TSS | 107.0 | (21.9) | 52.2 | (10.7) |
pH | (1) | (1) | (1) | (1) |
(1) Within the range of 7.5 to 10.0 at all times.
Wis. Admin. Code Department of Natural Resources NR 263.21