Wis. Admin. Code Department of Natural Resources NR 254.104

Current through August 26, 2024
Section NR 254.104 - New source performance standards

The discharge of wastewater pollutants from any new source subject to this subchapter may not exceed the following standards:

Table 173

Single Stand Recirculation Cold Rolling Mills

NSPS

Maximum for any 1 day

Average of

daily values for

30 consecutive

days

Pollutant or pollutant property

kg/kkg (pounds per 1,000 pounds) of product

TSS

0.00125

0.000626

O&G

0.000522

0.000209

Chromium(1)

0.0000209

0.0000084

Lead

0.0000094

0.0000031

Nickel(1)

0.0000188

0.0000063

Zinc

0.0000063

0.0000021

Naphthalene

0.0000021

Tetrachloroethylene

0.0000031

pH

(2)

(2)

(1) The limitations for chromium and nickel are applicable in lieu of those for lead and zinc when cold rolling wastewaters are treated with descaling or combination acid pickling wastewaters.

(2) Within the range of 6.0 to 9.0

Table 174

Multiple Stand Recirculation Cold Rolling Mills

NSPS

Maximum for any 1 day

Average of

daily values for

30 consecutive

days

Pollutant or pollutant property

kg/kkg (pounds per 1,000 pounds) of product

TSS

0.00250

0.00125

O&G

0.00104

0.000417

Chromium(1)

0.0000418

0.0000167

Lead

0.0000188

0.0000063

Nickel(1)

0.0000376

0.0000125

Zinc

0.0000125

0.0000042

Naphthalene

0.0000042

Tetrachloroethylene

0.0000063

pH

(2)

(2)

(1) The limitations for chromium and nickel are applicable in lieu of those for lead and zinc when cold rolling wastewaters are treated with descaling or combination acid pickling wastewaters.

(2) Within the range of 6.0 to 9.0

Table 175

Combination Cold Rolling Mills

NSPS

Maximum for any 1 day

Average of

daily values for

30 consecutive

days

Pollutant or pollutant property

kg/kkg (pounds per 1,000 pounds) of product

TSS

0.0326

0.0163

O&G

0.0136

0.00543

Chromium(1)

0.000543

0.000217

Lead

0.000244

0.0000814

Nickel(1)

0.000488

0.000163

Zinc

0.000163

0.0000542

Naphthalene

0.0000542

Tetrachloroethylene

0.0000813

pH

(2)

(2)

(1) The limitations for chromium and nickel are applicable in lieu of those for lead and zinc when cold rolling wastewaters are treated with descaling or combination acid pickling wastewaters.

Within the range of 6.0 to 9.0

Table 176

Single Stand Direct Application Cold Rolling Mills

NSPS

Maximum for any 1 day

Average of

daily values for

30 consecutive

days

Pollutant or pollutant property

kg/kkg (pounds per 1,000 pounds) of product

TSS

0.00626

0.00313

O&G

0.00261

0.00104

Chromium(1)

0.000104

0.0000418

Lead

0.0000469

0.0000156

Nickel(1)

0.0000939

0.0000313

Zinc

0.0000313

0.0000104

Naphthalene

0.0000104

Tetrachloroethylene

0.0000156

pH

(2)

(2)

The limitations for chromium and nickel are applicable in lieu of those for lead and zinc when cold rolling wastewaters are treated with descaling or combination acid pickling wastewaters.

(2) Within the range of 6.0 to 9.0

Table 177

Multiple Stand Direct Application Cold Rolling Mills

NSPS

Maximum for any 1 day

Average of

daily values for

30 consecutive

days

Pollutant or pollutant property

kg/kkg (pounds per 1,000 pounds) of product

TSS

0.0726

0.0363

O&G

0.0302

0.0121

Chromium(1)

0.00121

0.000484

Lead

0.000545

0.000182

Nickel(1)

0.00109

0.000363

Zinc

0.000363

0.000121

Naphthalene

0.000121

Tetrachloroethylene

0.000182

pH

(2)

(2)

(1) The limitations for chromium and nickel are applicable in lieu of those for lead and zinc when cold rolling wastewaters are treated with descaling or combination acid pickling wastewaters.

(2) Within the range of 6.0 to 9.0

Table 178

Cold Worked Pipe and Tube Using Water

NSPS

Maximum for any 1 day

Average of

daily values for

30 consecutive

days

Pollutant or pollutant property

kg/kkg (pounds per 1,000 pounds) of product

TSS

0.00125

0.000626

O&G

0.000522

0.000209

Chromium(1)

0.0000209

0.0000084

Lead

0.0000094

0.0000031

Nickel(1)

0.0000188

0.0000063

Zinc

0.0000063

0.0000021

pH

(2)

(2)

(1) The limitations for chromium and nickel are applicable in lieu of those for lead and zinc when cold rolling wastewaters are treated with descaling or combination acid pickling wastewaters.

(2) Within the range of 6.0 to 9.0

Table 179

Cold Worked Pipe and Tube Using Oil Solutions

NSPS

Maximum for any 1 day

Average of

daily values for

30 consecutive

days

Pollutant or pollutant property

kg/kkg (pounds per 1,000 pounds) of product

TSS

0.00125

0.000626

O&G

0.000522

0.000209

Chromium(1)

0.0000209

0.0000084

Lead

0.0000094

0.0000031

Nickel(1)

0.0000188

0.0000063

Zinc

0.0000063

0.0000021

Naphthalene

0.0000021

Tetrachloroethylene

0.0000031

pH

(2)

(2)

(1) The limitations for chromium and nickel are applicable in lieu of those for lead and zinc when cold rolling wastewaters are treated with descaling or combination acid pickling wastewaters.

(2) Within the range of 6.0 to 9.0

Wis. Admin. Code Department of Natural Resources NR 254.104

Cr. Register, May, 1989, No. 401, eff. 6-1-89.