The owner or operator shall design, construct and maintain an incinerator burning hazardous waste so that, when operated according to operating requirements specified under s. NR 664.0345, it will meet all of the following performance standards:
where:
Win = mass feed rate of one principal organic hazardous constituent (POHC) in the waste stream feeding the incinerator
Wout = mass emission rate of the same POHC present in exhaust emissions prior to release to the atmosphere
where:
Pc = corrected concentration of particulate matter
Pm = measured concentration of particulate matter
Y = measured concentration of oxygen in the stack gas, using the Orsat method for oxygen analysis of dry flue gas, presented in Method 3 in appendix A of 40 CFR part 60, incorporated by reference in s. NR 660.11
All hazardous waste incinerators except those operating under conditions of oxygen enrichment shall use this correction procedure. For incinerators operating under conditions of oxygen enrichment, the department will select an appropriate correction procedure and specify it in the facility license.
Wis. Admin. Code Department of Natural Resources NR 664.0343