Wis. Admin. Code Department of Natural Resources NR 465.03

Current through November 25, 2024
Section NR 465.03 - Symbols

The symbols used in this subchapter have the following meanings:

(1) "ac" means after the control system is installed and operated.
(2) "Ak" is the area of each natural draft opening k in a total enclosure, in square meters.
(3) "bc" means before control.
(4) "Caj" is the concentration of VHAP in gas stream j exiting the control device, in parts per million by volume.
(5) "Cbi" is the concentration of VHAP in gas stream i entering the control device, in parts per million by volume.
(6) "Cc" is the VHAP content of a finishing material c in kilograms of VHAP per kilogram of coating solids (kg VHAP/kg solids), as supplied. Also given in pounds of VHAP per pound of coating solids (lb VHAP/lb solids).
(7) "Cdi" is the concentration of VHAP in gas stream i entering the control device from the affected source, in parts per million by volume.
(8) "Cfk" is the concentration of VHAP in uncontrolled gas stream k emitted directly to the atmosphere from the affected source, in parts per million by volume.
(9) "E" is the emission limit achieved by an emission point or a set of emission points, in kg VHAP/kg solids (lb VHAP/lb solids).
(10) "F" is the control device efficiency, expressed as a fraction.
(11) "FV" is the average inward face velocity across all natural draft openings in a total enclosure, in meters per hour.
(12) "G" is the VHAP content of a contact adhesive, in kg VHAP/kg solids (lb VHAP/lb solids), as applied.
(13) "Mc" is the mass of solids in finishing material c used monthly, kg solids/month (lb solids/month).
(14) "N" is the capture efficiency, expressed as a fraction.
(15) "Qaj" is the volumetric flow rate of gas stream j exiting the control device, in dry standard cubic meters per hour.
(16) "Qbi" is the volumetric flow rate of gas stream i entering the control device, in dry standard cubic meters per hour.
(17) "Qdi" is the volumetric flow rate of gas stream i entering the control device from the emission point, in dry standard cubic meters per hour.
(18) "Qfk" is the volumetric flow rate of uncontrolled gas stream k emitted directly to the atmosphere from the emission point, in dry standard cubic meters per hour.
(19) "Qin i" is the volumetric flow rate of gas stream i entering the total enclosure through a forced makeup air duct, in standard cubic meters per hour, wet basis.
(20) "Qout j" is the volumetric flow rate of gas stream j exiting the total enclosure through an exhaust duct or hood, in standard cubic meters per hour, wet basis.
(21) "R" is the overall efficiency of the control system, expressed as a percentage.
(22) "S" is the VHAP content of a solvent, expressed as a weight fraction, added to finishing materials.
(23) "W" is the amount of solvent, in kilograms (pounds), added to finishing materials during the monthly averaging period.

Wis. Admin. Code Department of Natural Resources NR 465.03

CR 00-160: cr. Register August 2001 No. 548, eff. 9-1-01; CR 03-037: am. (intro.) Register March 2004 No. 579, eff. 4-1-04.