Current through Register Vol. XLI, No. 43, October 25, 2024
Section 36-10-5 - Roof Bolting5.1. For roof bolts and accessories addressed in ASTM F432-88, "Standard Specification for Roof and Rock Bolts and Accessories", the mine operator shall: 5.1.1. Obtain a manufacturer's certification that the material was manufactured and tested in accordance with the specifications of ASTM F432-88; and5.1.2. Make this certification available to an authorized representative of the Director.5.2. Roof bolts and accessories not addressed in ASTM F432-88 may be used, provided that the use of such materials is approved by the Director or his authorized representative based on: 5.2.1. Demonstrations which show that the materials have successfully supported the roof in an area of a coal mine with similar strata, opening dimensions and roof stresses; or5.2.2. Tests have shown the materials to be effective for supporting the roof in an area of the affected mine which has similar strata, opening dimensions and roof stresses as the area where the roof bolts are to be used. During the test process, access to the test area shall be limited to persons necessary to conduct the test.5.3.1. A bearing plate shall be firmly installed with each roof bolt.5.3.2. Bearing plates used directly against the mine roof shall be at least six (6) inches square or the equivalent, except that where the mine roof is firm and not susceptible to sloughing, bearing plates five (5) inches square or the equivalent may be used.5.3.3. Bearing plates used with wood or metal materials shall be at least four (4) inches square or the equivalent.5.3.4. Wooden materials that are used between a bearing plate and the mine roof in areas which will exist for three (3) years or more shall be treated to minimize deterioration.5.4. When washers are used with roof bolts, the washers shall conform to the shape of the roof bolt head, and bearing plate. 5.5.1. The diameter of finishing bits shall be within a tolerance of plus or minus 0.030 inch of the manufacturer's recommended hole diameter for the anchor used.5.5.2. When separate finishing bits are used, they shall be distinguishable from other bits.5.6. Tensioned roof bolts: 5.6.1. Roof bolts that provide support by creating a beam of laminated strata shall be at least thirty (30) inches long. Roof bolts that provide support by suspending the roof from overlying stronger strata shall be long enough to anchor at least twelve (12) inches into the stronger strata.5.6.2. Test holes, spaced at intervals specified in the roof control plan, shall be drilled to a depth of at least twelve (12) inches above the anchorage horizon of mechanically anchored tensioned bolts being used. When a test hole indicates that bolts would not anchor in competent strata, corrective action shall be taken.5.6.3. The installed torque or tension ranges for roof bolts as specified in the roof control plan shall maintain the integrity of the support system and shall not exceed the yield point of the roof bolt nor anchorage capacity of the strata.5.6.4. In each roof bolting cycle, the actual torque or tension of the first tensioned roof bolt installed with each drill head shall be measured immediately after it is installed. Thereafter, for each drill head used, at least one (1) roof bolt out of every four (4) installed shall be measured for actual torque or tension. If the torque or tension of any of the roof bolts measured is not within the range specified in the roof control plan, corrective action shall be taken.5.6.5. In working places from which coal is produced during any portion of a twenty-four (24) hour period, the actual torque or tension on at least one (1) out of every ten (10) previously installed mechanically anchored tensioned roof bolts shall be measured from the outby corner of the last open crosscut to the face in each advancing section. Corrective action shall be taken if the majority of the bolts measured: a. Do not maintain at least seventy percent (70%) of the minimum torque or tension specified in the roof control plan, fifty percent (50%) if the roof bolt plates bear against wood; or b. Have exceeded the maximum specified torque or tension by fifty percent (50%).5.6.6. The mine operator or a person designated by the operator shall certify by signature and date that measurements required by subsection 5.6.5 of this section have been made. This certification shall be maintained for at least one (1) year and shall be made available to an authorized representative of the Director and representatives of the miners.5.6.7. Tensioned roof bolts installed in the roof support pattern shall not be used to anchor trailing cables or used for any other purpose that could affect the tension of the bolt. Hanging trailing cables, line brattice, telephone lines, or other similar devices which do not place sudden loads on the bolts are permitted.5.6.8. Angle compensating devices shall be used to compensate for the angle when tensioned roof bolts are installed at angles greater than five (5) degrees from the perpendicular to the bearing plate.5.7. Non-tensioned grouted roof bolts. The first non-tensioned grouted roof bolt installed during each roof bolting cycle shall be tested during or immediately after the first row of bolts has been installed. If the bolt tested does not withstand at least one hundred fifty (150) foot-pounds of torque without rotating in the hole, corrective action shall be taken.5.8. Removal of Roof Hazards. Prior to or during bolting operations in working places, the person responsible for performing such work shall immediately notify a supervisor if abnormal or hazardous conditions are encountered. No further work shall be performed until a supervisor examines the area where he has been informed that abnormal or hazardous conditions exist and directs the correction of such condition.5.9. Working Around Roof Bolting Machines. On all roof bolting machines except continuous mining machines with integral roof bolters, during the time that the ATRS system is being engaged against or retracted from the mine roof, all persons except those specified below shall be outby the last row of permanent roof supports. This requirement shall not apply to the equipment operator, provided that adequate protection is provided for the equipment operator while setting the ATRS. 5.10. Roof Bolting Machines - Requirements. Roof bolting machines used in seams forty-eight (48) inches or higher shall be equipped with a mechanical means of holding the drill steel during drilling operations, which minimizes the need for the equipment operator to handle the drill steel. The Director may require such devices on roof bolting machines used in seams under forty-eight (48) inches where the technology for such equipment to operate under these conditions is available.5.11. Fast raise on boom feed roof bolting machines: All boom feed roof bolting machines utilizing fast feed will be provided with controls that are designed by the equipment manufacturer and approved by the Director of the Office of Miners' Health, Safety and Training that minimize, the operators' exposure to the pinch point area, while engaging the fast feed function. The fast feed will be designed in such a manner that minimizes accidental activation. Fast feed is defined as a feed rate greater than twelve (12) inches per second.