TABLE 501.1 (2)1,3
Number of Bathrooms | 1 to 1.5 | 2 to 2.5 | 3 to 3.5 | ||||||||
Number of Bedrooms | 1 | 2 | 3 | 2 | 3 | 4 | 5 | 3 | 4 | 5 | 6 |
First Hour Rating2, Gallons | 38 | 49 | 49 | 49 | 62 | 62 | 74 | 62 | 74 | 74 | 74 |
Notes: | 1The first hour rating is found on the "Energy Guide" label. 2Nonstorage and solar water heaters shall be sized to meet the appropriate first hour rating as shown in the table, and shall be capable of delivering hot water at the maximum system demand flow, as calculated in Section 610.0 or Appendix A, as applicable. 3For replacement water heaters, see Section 102.4. |
EXCEPTIONS: | 1. Water heaters manufactured prior to January 1, 2021. 2. Electric storage water heaters other than heat pump type water heaters manufactured prior to January 1, 2022. |
Sections 506.1 through 506.9 are not adopted.
Sections 507.6 through 507.9 are not adopted.
Sections 507.18 through 507.22 are not adopted.
Wash. Admin. Code § 51-56-0500
Statutory Authority: RCW 19.27.074, 19.27.031 and chapters 19.27 and 34.05 RCW. 13-04-054, § 51-56-0500, filed 2/1/13, effective 7/1/13; 11-05-037, § 51-56-0500, filed 2/8/11, effective 7/1/13; 10-03-101, § 51-56-0500, filed 1/20/10, effective 7/1/10. Statutory Authority: RCW 19.27.190, 19.27.020 and chapters 19.27 and 34.05 RCW. 07-01-094, § 51-56-0500, filed 12/19/06, effective 7/1/07. Statutory Authority: RCW 19.27.031 and 19.27.074. 04-01-110, § 51-56-0500, filed 12/17/03, effective 7/1/04; 02-01-114, § 51-56-0500, filed 12/18/01, effective 7/1/02.