Wash. Admin. Code § 51-11R-51000

Current through Register Vol. 24-21, November 1, 2024
Section 51-11R-51000 - Chapter 6-Referenced standards

This chapter lists the standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard, the standard identification, the effective date and title, and the section or sections of this document that reference the standard. The application of the referenced standards shall be as specified in Section R106.

AAMA

American Architectural Manufacturers Association 1827 Walden Office Square

Suite 550

Schaumburg, IL 60173-4268

Standard reference number

Title

Referenced in code section number

AAMA/WDMA/CSA 101/I.S.2/A C440-17

North American Fenestration

Standard/Specifications for Windows, Doors and Unit Skylights ........

R402.4.2

ACCA

Air Conditioning Contractors of America

2800 Shirlington Road, Suite 300

Arlington, VA 22206

Standard reference number

Title

Referenced in code section number

Manual J-16

Residential Load Calculation Eighth Edition ........

R403.7

Manual S-14

Residential Equipment ........

R403.7

ANSI

American National Standards Institute 25 West 43rd Street, 4th Floor New York, NY 10036

Standard reference number

Title

Referenced in code section number

Z21.50-2016/CSA 2.22-2016

Vented Decorative Gas Appliances ........

R403.7.1

Z21.88-2017/CSA 2.33-2017

Vented Gas Fireplace Heaters ........

R403.7.1

Z21.40.2-1996

Gas-fired, Work Activated Air-Conditioning and Heat Pump Appliances (Internal Combustion) ........

Table R406.3

Z21.40.4-1996

Performance Testing and Rating of Gas-Fired, Air-Conditioning and Heat Pump Appliances ........

Table R406.3

APSP

The Association of Pool and Spa Professionals 2111 Eisenhower Avenue, Suite 500 Alexandria, VA 22206

Standard reference number

Title

Referenced in code section number

ANSI/APSP/ICC 14-2019

American National Standard for Portable Electric Spa Energy Efficiency ........

R403.11

ANSI/APSP/ICC 15a-2011

American National Standard for Residential Swimming Pool and Spa Energy Efficiency- Includes Addenda A approved January 9, 2013 ........

R403.12

ASHRAE

American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. 1791 Tullie Circle, N.E. Atlanta, GA 30329-2305

Standard reference number

Title

Referenced in code section number

ASHRAE-2021

ASHRAE 193-2010 (RA 2014)

ASHRAE Handbook of Fundamentals ........

Method of Test for Determining the Airtightness of HVAC Equipment ........

R402.1.5, Table R405.5.2(1)

R403.3.4.1

ASTM

ASTM International

100 Barr Harbor Drive

West Conshohocken, PA 19428-2859

Standard reference number

Title

Referenced in code section number

C1363-11

Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus ........

R303.1.4.1

E283-2004 (2012)

Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls and Doors Under Specified Pressure Differences Across the Specimen ........

R402.4.3

E779-2010 (2018)

Standard Test Method for Determining Air Leakage Rate by Fan Pressurization ........

R402.4.1.2

E1554/E1554M-E2013

Standard Test Method for Determining Air Leakage of Air Distribution Systems by Fan Pressurization ........

R403.3.5

E1827-2011 (2017)

Standard Test Methods for Determining Airtightness of Building Using an Orifice Blower Door ........

R402.4.1.2

E2178-2013

Standard Test Method for Air Permeance of Building Materials ........

R303.1.5

E3158-2018

Standard Test Method for Measuring the Air Leakage Rate of a Large or Multizone Building ........

R402.4.1.2

CSA

Canadian Standards Association

5060 Spectrum Way

Mississauga, Ontario, Canada L4W 5N6

Standard reference number

Title

Referenced in code section number

AAMA/WDMA/CSA 101/I.S.2/A440-17

North American Fenestration Standard/Specification for Windows, Doors and Unit Skylights ........

R402.4.2

CSA 55.1-2015

Test Method for Measuring Efficiency and Pressure Loss of Drain Water Heat Recovery Systems ........

R403.5.4, Table R406.2

CSA 55.2-2015

Drain Water Heat Recovery Units ........

R403.5.4

CSA P.4.1-15

Testing Method for Measuring Annual Fireplace Efficiency ........

R403.7.1

DASMA

Door and Access Systems Manufacturers Association

1300 Sumner Avenue

Cleveland, OH 44115-2851

105-2017

Test Method for Thermal Transmittance and Air Infiltration of Garage Doors and Rolling Doors ........

R303.1.3

HVI

Home Ventilating Institute

1000 North Rand Road, Suite 214

Wauconda, IL 60084

916-18

Airflow Test Procedure ........

R303.1.3

ICC

International Code Council, Inc.

500 New Jersey Avenue, N.W.

6th Floor

Washington, DC 20001

Standard reference number

Title

Referenced in code section number

ANSI/APSP/ICC 14-2019

American National Standard for Portable Electric Spa Energy Efficiency ........

R403.11

ANSI/APSP/ICC 15a-2011

American National Standard for Residential Swimming Pool and Spa Energy Efficiency- Includes Addenda A approved January 9, 2013 ........

R403.12

ANSI/RESNET/ICC 380-2019

Standard for Testing Airtightness of building, Dwelling Unit and Sleeping Unit Enclosures; Airtightness of Heating and Cooling Air Distribution Systems, and Airflow of Mechanical Ventilation Systems ........

R402.4.1.2

IBC-21

International Building Code ........

R201.3, R303.2, R402.11, R4501.4

ICC 400-17

Standard on the Design and Construction of Log Structures ........

Table R402.1.1

ICC 500-2020

ICC/NSSA Standard for the Design and Construction of Storm Shelters ........

R402.5

IFC-21

International Fire Code ........

R201.3, R501.4

IFGC-21

International Fuel Gas Code ........

R201.3, R501.4

IFGC-21

International Mechanical Code ........

R201.3, R403.3.2, R403.6, R501.4

IPMC-21

International Property Maintenance Code ........

R501.4

IRC-21

International Residential Code ........

R104.2.1, R201.3, R303.2, R401.2, R403.2.2, R403.5, R406.1, R406.2, Table R406.2

IEEE

The Institute of Electrical and Electronic Engineers, Inc.

3 Park Avenue

New York, NY 10016-5997

Standard reference number

Title

Referenced in code section number

515.1-2012

IEEE Standard for the Testing, Design, Installation and Maintenance of Electrical Resistance Trace Heating for Commercial Applications ........

R403.5.1.2

ISO

International Organization for Standardization 1, rue de Varembe, Case postale 56, CH-1211 Geneva, Switzerland

Standard reference number

Title

Referenced in code section number

ISO/IEC 17024-2012

Conformity Assessment: General requirements for bodies operating certification of persons ........

R402.4.1.2

NEEA

Northwest Energy Efficiency Alliance 421 S.W. 6th Ave., Suite 600 Portland, OR 97204

Standard reference number

Title

Referenced in code section number

NEEA-2011

Northern Climate Specification for Heat Pump Water Heaters, Vers. 4.0 ........

Table R406.3

NEEA-2019

Advanced Water Heating Specifications for Gas-Fueled Residential Storage Water Heaters, Version 1.0 .........

Table R406.3

NEEP

Northeast Energy Efficiency Partnership, Inc. 24 School Street, 2nd Floor Boston, MA 02108-4314

Standard reference number

Title

Referenced in code section number

ccASHP Version 3.1

Cold Climate Air Source Heat Pump (ccASHP) Product List and Specifications: https://neep.org/heating-electrification/ccashp-specification-product-list ........

Table R406.3

NEMA

National Electrical Manufacturers Association 1300 17th Street N No. 900 Arlington, VA 22209

Standard reference number

Title

Referenced in code section number

OS4-2016

Requirements for Air-Sealed Boxes for ........ Electrical and Communications Applications

R402.4.4

NFPA

National Fire Protection Association 1 Batterymarch Park Quincy, MA 02169-7417

Standard reference number

Title

Referenced in code section number

70-20

National Electrical Code ........

R501.4

NFRC

National Fenestration Rating Council, Inc. 6305 Ivy Lane, Suite 140 Greenbelt, MD 20770

Standard reference number

Title

Referenced in code section number

100-2020

200-2020

400-2020

Procedure for Determining Fenestration Products U-factors ........

Procedure for Determining Fenestration Product Solar Heat Gain Coefficients and Visible Transmittance at Normal Incidence ........

Procedure for Determining Fenestration Product Air Leakage ........

R303.1.3

R303.1.3

R402.4.2

UL

Underwriters Laboratory 333 Pfingsten Road Northbrook, IL 60062

Standard reference number

Title

Referenced in code section number

UL 127-11

Factory Built Fireplace ........

R402.3.6

UL 515-11

Electric Resistance Heat Tracing for Commercial and Industrial Applications ........

R403.5.1.2

UL 907-94

Fireplace Accessories (with revisions through April 2010) ........

R402.3.6

US-FTC

United States-Federal Trade Commission 600 Pennsylvania Avenue N.W. Washington, DC 20580

Standard reference number

Title

Referenced in code section number

C.F.R. Title 16 (2015)

R-value Rule ........

Rule R303.1.4

WDMA

Window and Door Manufacturers Association 1400 East Touhy Avenue, Suite 470 Des Plaines, IL 60018

Standard reference number

Title

Referenced in code section number

AAMA/WDMA/CSA 101/I.S.2/A440-17

North American Fenestration Standard/Specification for Windows, Doors and Unit Skylights ........

R402.4.2

WSU

Washington State University Energy Extension Program 905 Plum Street S.E., Bldg 3 P.O. Box 43165 Olympia, WA 98506-3166

Standard reference number

Title

Referenced in code section number

WSU RS 33

Duct Testing Standard for New and Existing Construction Publication No. WSUEEP15-016 ........

R403.3.3

Wash. Admin. Code § 51-11R-51000

Adopted by WSR 16-02-127, Filed 1/6/2016, effective 7/1/2016
Amended by WSR 20-01-047, Filed 12/9/2019, effective 7/1/2020
Amended by WSR 23-02-060, Filed 1/3/2023, effective 7/1/2023
Amended by WSR 24-03-084, Filed 1/16/2024, effective 3/15/2024