Wash. Admin. Code § 51-11C-610333

Current through Register Vol. 24-21, November 1, 2024
Section 51-11C-610333 - Section A103.3.3 - Double stud wall

A103.3.3 Double stud wall. Tables A103.3.3(1) and A103.3.3(2): Assumes an exterior structural wall and a separate interior, nonstructural wall. Insulation is placed in both wall cavities and in the space between the two walls. Stud spacing is assumed to be on 24 inch centers for both walls.

Table A103.3.3(1) 2 x 6 + 2 x 4: Double Wood Stud

Siding Material/Frame Type

Batt Configuration

Lapped Wood

T1-11

Exterior

Middle

Interior

STD

ADV

STD

ADV

R-19

------

R-11

0.040

0.037

0.041

0.038

R-19

------

R-19

0.034

0.031

0.035

0.032

R-19

R-8

R-11

0.029

0.028

0.031

0.029

R-19

R-11

R-11

0.027

0.026

0.028

0.027

R-19

R-11

R-19

0.024

0.023

0.025

0.023

R-19

R-19

R-19

0.021

0.020

0.021

0.020

Table A103.3.3(2) 2 x 4 + 2 x 4: Double Wood Stud

Siding Material/Frame Type

Batt Configuration

Lapped Wood

T1-11

Exterior

Middle

Interior

STD

ADV

STD

ADV

R-11

--------

R-11

0.050

0.046

0.052

0.048

R-19

--------

R-11

0.039

0.037

0.043

0.039

R-11

R-8

R-11

0.037

0.035

0.036

0.036

R-11

R-11

R-11

0.032

0.031

0.033

0.032

R-13

R-13

R-13

0.029

0.028

0.029

0.028

R-11

R-19

R-11

0.026

0.026

0.027

0.026

Wash. Admin. Code § 51-11C-610333