Wash. Admin. Code § 51-11C-610331

Current through Register Vol. 24-23, December 1, 2024
Section 51-11C-610331 - Section A103.3.1 - Single stud wall

A103.3.1 Single-stud wall. Tables A103.3.1(1) through A103.3.1(8): Assumes either 2 x 4 or 2 x 6 studs framed on 16 or 24 inch centers. Headers are solid for 2 x 4 walls and double 2x for 2 x 6 walls, with either dead-air or rigid-board insulation in the remaining space.

TABLE A103.3.1(1)

2 x 4 Single Wood Stud: R-11 Batt

Siding Material/Framing Type

Lapped Wood

T1-11

R-value of

FoamBoard

STD

ADV

STD

ADV

NOTE:

Nominal Batt R-value:

R-11 at 3.5 inch thickness

Installed Batt R-value:

R-11 in 3.5 inch cavity

0

0.088

0.084

0.094

0.090

1

0.080

0.077

0.085

0.082

2

0.074

0.071

0.078

0.075

3

0.069

0.066

0.072

0.070

4

0.064

0.062

0.067

0.065

5

0.060

0.058

0.063

0.061

6

0.056

0.055

0.059

0.057

7

0.053

0.052

0.055

0.054

8

0.051

0.049

0.052

0.051

9

0.048

0.047

0.050

0.049

10

0.046

0.045

0.047

0.046

11

0.044

0.043

0.045

0.044

12

0.042

0.041

0.043

0.042

TABLE A103.3.1(2)

2 x 4 Single Wood Stud: R-13 Batt

Siding Material/Framing Type

Lapped Wood

T1-11

R-value of

FoamBoard

STD

ADV

STD

ADV

NOTE:

Nominal Batt R-value:

R-13 at 3.63 inch thickness

Installed Batt R-value:

R-12.7 in 3.5 inch cavity

0

0.082

0.078

0.088

0.083

1

0.075

0.072

0.080

0.076

2

0.069

0.066

0.073

0.070

3

0.065

0.062

0.068

0.065

4

0.060

0.058

0.063

0.061

5

0.057

0.055

0.059

0.057

6

0.053

0.052

0.056

0.054

7

0.051

0.049

0.052

0.051

8

0.048

0.047

0.050

0.048

9

0.046

0.045

0.047

0.046

10

0.044

0.043

0.045

0.044

11

0.042

0.041

0.043

0.042

12

0.040

0.039

0.041

0.040

TABLE A103.3.1(3)

2 x 4 Single Wood Stud: R-15 Batt

Siding Material/Framing Type

Lapped Wood

T1-11

R-value of

FoamBoard

STD

ADV

STD

ADV

NOTE:

Nominal Batt R-value:

R-15 at 3.5 inch thickness

Installed Batt R-value:

R-15 in 3.5 inch cavity

0

0.076

0.071

0.081

0.075

1

0.069

0.065

0.073

0.069

2

0.064

0.061

0.068

0.069

3

0.060

0.057

0.063

0.059

4

0.056

0.053

0.059

0.056

5

0.053

0.051

0.055

0.052

6

0.050

0.048

0.052

0.050

7

0.047

0.046

0.049

0.047

8

0.045

0.044

0.047

0.045

9

0.043

0.042

0.044

0.043

10

0.041

0.040

0.042

0.041

11

0.039

0.038

0.041

0.039

12

0.038

0.037

0.039

0.038

TABLE A103.3.1(4)

2 x 6 Single Wood Stud: R-19 Batt

Siding Material/Framing Type

Lapped Wood

T1-11

R-value of

FoamBoard

STD

INT

ADV

STD

INT

ADV

NOTE:

Nominal Batt R-value:

R-19 at 6 inch thickness

Installed Batt R-value:

R-18 in 5.5 inch cavity

0

0.062

0.058

0.055

0.065

0.061

0.058

1

0.058

0.055

0.052

0.060

0.057

0.055

2

0.054

0.052

0.050

0.056

0.054

0.051

3

0.051

0.049

0.047

0.053

0.051

0.049

4

0.048

0.046

0.045

0.050

0.048

0.046

5

0.046

0.044

0.043

0.048

0.046

0.044

6

0.044

0.042

0.041

0.045

0.044

0.042

7

0.042

0.040

0.039

0.043

0.042

0.040

8

0.040

0.039

0.038

0.041

0.040

0.039

9

0.038

0.037

0.035

0.039

0.038

0.037

10

0.037

0.036

0.035

0.038

0.037

0.036

11

0.036

0.035

0.034

0.036

0.035

0.035

12

0.034

0.033

0.033

0.035

0.034

0.033

TABLE A103.3.1(5)

2x 6 Single Wood Stud: R-21 Batt

Siding Material/Framing Type

Lapped Wood

T1-11

R-value of

FoamBoard

STD

INT

ADV

STD

INT

ADV

NOTE:

Nominal Batt R-value:

R-21 at 5.5 inch thickness

Installed Batt R-value:

R-21 in 5.5 inch cavity

0

0.057

0.054

0.051

0.060

0.056

0.053

1

0.054

0.051

0.048

0.056

0.053

0.050

2

0.050

0.048

0.045

0.052

0.050

0.047

3

0.048

0.045

0.043

0.049

0.047

0.045

4

0.045

0.043

0.041

0.047

0.045

0.043

5

0.043

0.041

0.040

0.044

0.042

0.041

6

0.041

0.039

0.038

0.042

0.041

0.039

7

0.039

0.038

0.036

0.040

0.039

0.037

8

0.038

0.036

0.035

0.039

0.037

0.036

9

0.036

0.035

0.034

0.037

0.036

0.035

10

0.035

0.034

0.033

0.036

0.035

0.033

11

0.033

0.033

0.032

0.034

0.033

0.032

12

0.032

0.031

0.031

0.033

0.032

0.031

TABLE A103.3.1(6)

2 x 6 Single Wood Stud: R-22 Batt

Siding Material/Framing Type

Lapped Wood

T1-11

R-value of

FoamBoard

STD

INT

ADV

STD

INT

ADV

NOTE:

Nominal Batt R-value:

R-22 at 6.75 inch thickness

Installed Batt R-value:

R-20 in 5.5 inch cavity

0

0.059

0.055

0.052

0.062

0.058

0.054

1

0.055

0.052

0.049

0.057

0.054

0.051

2

0.052

0.049

0.047

0.054

0.051

0.048

3

0.049

0.046

0.044

0.050

0.048

0.046

4

0.046

0.044

0.042

0.048

0.046

0.044

5

0.044

0.042

0.041

0.045

0.043

0.042

6

0.042

0.040

0.039

0.043

0.042

0.040

7

0.040

0.039

0.037

0.041

0.040

0.038

8

0.038

0.037

0.036

0.039

0.038

0.037

9

0.037

0.036

0.035

0.038

0.037

0.035

10

0.035

0.034

0.033

0.036

0.035

0.034

11

0.034

0.033

0.032

0.035

0.034

0.033

12

0.033

0.032

0.031

0.034

0.033

0.032

TABLE A103.3.1(7)

2 x 6 Single Wood Stud: Two R-11 Batts

Siding Material/Framing Type

Lapped Wood

T1-11

R-value of

FoamBoard

STD

INT

ADV

STD

INT

ADV

NOTE:

Nominal Batt R-value:

R-22 at 7 inch thickness

Installed Batt R-value:

R-18.9 in 5.5 inch cavity

0

0.060

0.057

0.054

0.063

0.059

0.056

1

0.056

0.053

0.051

0.059

0.056

0.053

2

0.053

0.050

0.048

0.055

0.052

0.050

3

0.050

0.048

0.046

0.052

0.049

0.047

4

0.047

0.045

0.044

0.049

0.047

0.045

5

0.045

0.043

0.042

0.046

0.045

0.043

6

0.043

0.041

0.040

0.044

0.043

0.041

7

0.041

0.040

0.038

0.042

0.041

0.039

8

0.039

0.038

0.037

0.040

0.039

0.038

9

0.038

0.037

0.036

0.039

0.038

0.036

10

0.036

0.035

0.034

0.037

0.036

0.035

11

0.035

0.034

0.033

0.036

0.035

0.034

12

0.034

0.033

0.032

0.034

0.034

0.033

TABLE A103.3.1(8)

2 x 8 Single Stud: R-25 Batt

Siding Material/Framing Type

Lapped Wood

T1-11

R-value of

FoamBoard

STD

INT

ADV

STD

INT

ADV

NOTE:

Nominal Batt R-value:

R-25 at 8 inch thickness

Installed Batt R-value:

R-23.6 in 7.25 inch cavity

0

0.051

0.047

0.045

0.053

0.049

0.046

1

0.048

0.045

0.043

0.049

0.046

0.044

2

0.045

0.043

0.041

0.047

0.044

0.042

3

0.043

0.041

0.039

0.044

0.042

0.040

4

0.041

0.039

0.037

0.042

0.040

0.038

5

0.039

0.037

0.036

0.040

0.038

0.037

6

0.037

0.036

0.035

0.038

0.037

0.036

7

0.036

0.035

0.033

0.037

0.035

0.034

8

0.035

0.033

0.032

0.035

0.034

0.033

9

0.033

0.032

0.031

0.034

0.033

0.032

10

0.032

0.031

0.030

0.033

0.032

0.031

11

0.031

0.030

0.029

0.032

0.031

0.030

12

0.030

0.029

0.028

0.031

0.030

0.029

Wash. Admin. Code § 51-11C-610331

Statutory Authority: RCW 19.27A.020, 19.27A.025 and chapters 19.27 and 34.05 RCW. 13-04-056, § 51-11C-610331, filed 2/1/13, effective 7/1/13.