Wash. Admin. Code § 51-11C-610225

Current through Register Vol. 25-01, January 1, 2025
Section 51-11C-610225 - Tables A102.2.5 - Default U-factors for metal building roofs

Table A102.2.5 Default U-factors for Metal Building Roofs

Overall U-Factor for Assembly of Base Roof Plus Continuous Insulation (uninterrupted by framing) Rated R-Value of Continuous Insulation

Insulation System

Rated R-Value of Insulation

Overall U-Factor for Entire Base Roof Assembly

R-6.5

R-13

R-19.5

R-26

R-32.5

R-39

Standing Seam Roofs with Thermal Spacer Blocksa, b

None

1.280

0.137

0.073

0.049

0.037

0.030

0.025

R-10

0.115

0.066

0.046

0.035

0.029

0.024

0.021

Single

R-11

0.107

0.063

0.045

0.035

0.028

0.024

0.021

Layer

R-13

0.101

0.061

0.044

0.034

0.028

0.024

0.020

R-16

0.096

0.059

0.043

0.033

0.027

0.023

0.020

R-19

0.082

0.053

0.040

0.031

0.026

0.022

0.020

R-10 + R-10

0.088

0.056

0.041

0.032

0.027

0.023

0.020

R-10 + R-11

0.086

0.055

0.041

0.032

0.027

0.023

0.020

R-11 + R-11

0.085

0.055

0.040

0.032

0.026

0.023

0.020

R-10 + R-13

0.084

0.054

0.040

0.032

0.026

0.023

0.020

Double

R-11 + R-13

0.082

0.053

0.040

0.032

0.026

0.022

0.020

Layer

R-13 + R-13

0.075

0.050

0.038

0.030

0.025

0.022

0.019

R-10 + R-19

0.074

0.050

0.038

0.030

0.025

0.022

0.019

R-11 + R-19

0.072

0.049

0.037

0.030

0.025

0.022

0.019

R-13 + R-19

0.068

0.047

0.036

0.029

0.025

0.021

0.019

R-16 + R-19

0.065

0.046

0.035

0.029

0.024

0.021

0.018

R-19 + R-19

0.060

0.043

0.034

0.028

0.023

0.020

0.018

Liner

R-19 + R-11

0.035

System

R-25 + R-11

0.031

R-30 + R-11

0.029

R-25 + R-11 + R-11

0.026

Filled Cavity with Thermal Spacer Blocksc

R-10 + R-19

0.057

0.042

0.033

0.027

0.023

0.020

0.018

Standing Seam Roofs without Thermal Spacer Blocks

Liner

System

R-19 + R-11

0.040

Thru-Fastened Roofs without Thermal Spacer Blocks

Single

R-10

0.184

Layer

R-11

0.182

R-13

0.174

R-16

0.157

R-19

0.151

Liner System

R-19 + R-11

0.044

(Multiple R-values are listed in order from inside to outside)

aA standing seam roof clip that provides a minimum 1.5 inch distance between the top of the purlins and the underside of the metal roof panels is required.

bA minimum R-3 thermal spacer block is required.

cA minimum R-5 thermal spacer block is required.

Wash. Admin. Code § 51-11C-610225

Statutory Authority: RCW 19.27A.020, 19.27A.025 and chapters 19.27 and 34.05 RCW. 13-04-056, § 51-11C-610225, filed 2/1/13, effective 7/1/13.