EXCEPTIONS: | 1. Energy using equipment used by a manufacturing, industrial or commercial process other than for conditioning spaces or maintaining comfort and amenities for the occupants are exempt from all Section C403 subsections except for Section C403.3.2, Tables C403.3.2 (1) through (16) inclusive, SectiC403.9.2.1, C403.10.3, C403.11.2, and C403.11.3, center and computer room HVAC equipment is not coverby this exception. 2. Data center systems are exempt from Sections C403.4 and C403.5. |
EXCEPTIONS: | 1. Buildings where the sum of the conditioned floor area of office, retail, education, library and multifamily spaces is less than 5,000 square feet. 2. HVAC systems using district heating water, chilled water or steam. 3. HVAC systems connected to a low-carbon district energy exchange system. 4. HVAC systems not included in Table D601.10.1. 5. HVAC systems with chilled water supplied by absorption chillers, heat recovery chillers, water to water heat pumps, air to water heat pumps, or a combination of air and water cooled chillers on the same chilled water loop. 6. HVAC systems included in Table D601.10.1 with parameters in Table D601.10.2 not identified as applicable to that HVAC system type. 7. HVAC systems served by heating water plants that include air to water or water to water heat pumps. 8. Underfloor air distribution and displacement ventilation HVAC systems. 9. Space conditioning systems that do not include mechanical cooling. 10. Alterations to existing buildings that do not substantially replace the entire HVAC system and are not serving initial build-out construction. 11. HVAC systems meeting all the requirements of the standard reference design HVAC system in Table D602.11, Standard Reference Design HVAC Systems. 12. Buildings or areas of medical office buildings that comply fully with ASHRAE Standard 170 including, but not limited to, surgical centers, or that are required by other applicable codes or standards to provide 24/7 air handling unit operation. 13. HVAC systems serving the following areas and spaces: 13.1. Laundry rooms. 13.2. Elevator machine rooms. 13.3. Mechanical and electrical rooms. 13.4. Data centers and computer rooms. 13.5. Laboratories with fume hoods. 13.6. Locker rooms with more than two showers. 13.7. Natatoriums and rooms with saunas. 13.8. Restaurants and commercial kitchens with total cooking capacity greater than 100,000 Btu/h. 13.9. Areas of buildings with commercial refrigeration equipment exceeding 100 kW of power input. 13.10. Cafeterias and dining rooms. |
Wash. Admin. Code § 51-11C-40310
Statutory Authority: RCW 19.27A.020, 19.27A.025 and chapters 19.27 and 34.05 RCW. 13-04-056, § 51-11C-40310, filed 2/1/13, effective 7/1/13.