Wash. Admin. Code § 458-40-680

Current through Register Vol. 24-20, October 15, 2024
Section 458-40-680 - Timber excise tax-Volume har-vested-Approved scaling and grading methods-Sample scaling-Conversions
(1)Introduction. The acceptable log scaling and grading standard for stumpage value areas 1, 2, 3, 4, 5, and 9 is the Scribner Decimal C log rule as described in the most current edition of the "Official Log Scaling and Grading Rules" developed and authored by the Northwest Log Rules Advisory Group. The acceptable log scaling standard for stumpage value areas 6 and 7 is the Scribner Decimal C log rule described in the most current edition of the "Eastside Log Scaling Handbook" as published by the Northwest Log Rules Advisory Group, except that timber harvested in stumpage value areas 6 and 7 must be scaled using the current regional taper rules at the point of origin.
(2)Special services scaling. Special services scaling as described in the "Official Log Scaling and Grading Rules" developed and authored by the Northwest Log Rules Advisory Group may not be used for tax reporting purposes without prior written approval of the department of revenue.
(3)Sample scaling. Sample scaling may not be used for tax reporting purposes without prior written approval of the department of revenue. To be approved, sample scaling must be in accordance with the following guidelines:
(a) Sample selection, scaling, and grading must be conducted on a continuous basis as the unit is harvested.
(b) The sample must be taken in such a manner to assure random, unbiased sample selection in accordance with accepted statistical tests of sampling.
(c) The sample used to determine total volume, species, and quality of timber harvested for a given reporting period must have been taken during that period.
(d) Sample frequency must be large enough to meet board foot variation accuracy limits of plus or minus two and five-tenths percent standard error at the ninety-five percent confidence level.
(e) Harvesters, or a purchaser with an approved sample scaling method, must maintain sufficient supporting documentation to allow the department of revenue to verify source data, and test statistical reliability of sample scale systems.
(f) Exceptions: Sampling designs and accuracy standards other than those described herein may only be used with the prior written approval of the department of revenue.
(4)Conversions to Scribner Decimal C Scale. The following definitions, tables, and conversion factors must be used in determining taxable volume for timber harvested that was not originally scaled by the Scribner Decimal C Log Rule. Conversion methods other than those listed are not to be used for tax reporting purposes without prior written approval of the department of revenue. Harvesters who wish to use a method of conversion other than those listed below must obtain written approval from the department of revenue before harvesting. Purchasers may obtain written approval of a sample scaling method from the department of revenue. The department will maintain a list of purchasers with an approved sample scaling method. A harvester may obtain this list and a summary of the approved method for specific purchasers from the department of revenue. If a harvester has not obtained approval of a sample scaling method before harvesting, the harvester may use a purchaser's approved sample scaling method. If the harvester, or purchaser, fails to use an approved sample scaling method or other method of conversion approved by these rules to set the purchase price, the department will establish its own method, as the circumstances require, to determine a reasonable estimate of the volume of timber sold.
(a)Weight measurement. If the sole unit of measure used to set the purchase price for logs from harvest units was weight, and the harvester does not use an approved method of sample scaling to determine volume for the stumpage value tables, the following tables must be used for converting to Scribner Decimal C, if the harvest volume per species meets the definition listed in the table. If weight is the sole measure used for a harvest unit and the harvest volume per species does not meet the definition listed in the table below, the department will establish its own method, as the circumstances require, to determine a reasonable estimate of the volume of timber sold. Harvesters must keep records to substantiate the species and quality codes reported. For tax reporting purposes, a ton equals 2,000 pounds.

(Stumpage Value Areas 1, 2, 3, 4, 5, & 9)

BOARD FOOT WEIGHT SCALE FACTORS

(TONS/MBF)

Species

Quality code

1

Douglas-fir1

7.50

Western Hemlock2

8.25

Western Redcedar3

7.0

Red Alder4

7.80

Chipwood

9.0

1 Includes Douglas-fir, Western Larch, Western White Pine and Sitka Spruce. Only for volume including less than 25% No. 2 sawmill or better log grades.

2 Includes Western Hemlock, Mountain Hemlock, Pacific Silver Fir, Noble Fir, Grand Fir, Subalpine Fir, Lodgepole Pine and other conifers not separately designated. Pacific Silver Fir, Noble Fir, Grand Fir, and Subalpine Fir are all commonly referred to as "White Fir." Only for volume including less than 25% No. 2 sawmill or better log grades.

3 Includes Alaska-cedar.

4 Maple, Black Cottonwood and other hardwoods. Only for volume including less than 40% No. 3 sawmill or better log grades.

(Stumpage Value Areas 6 & 7)

BOARD FOOT WEIGHT SCALE FACTORS

(TONS/MBF)

Species

Quality code

1

Ponderosa Pine1

6.50

Douglas-fir 2

5.50

Lodgepole Pine

6.0

Western Hemlock 3

5.50

Englemann Spruce

4.50

Western Redcedar 4

4.50

Chipwood

9.0

Small Logs

6.50

1 Only for volume with 10 or more logs 16 feet long per thousand board feet Scribner scale.

2 Includes Western Larch.

3 Includes Western Hemlock, Mountain Hemlock, Pacific Silver Fir, Noble Fir, Grand Fir, Subalpine Fir, and other conifers not separately designated. Pacific Silver Fir, Noble Fir, Grand Fir, and Subalpine Fir are all commonly referred to as "White Fir."

4 Includes Alaska-cedar.

(b)Cord measurement. For the purposes of converting cords into Scribner volume:
(i) In stumpage value areas 1, 2, 3, 4, 5, and 9 logs with an average scaling diameter of 8 inches and larger must be converted to Scribner volume using 400 board feet per cord. Logs having an average scaling diameter of less than 8 inches must be converted to Scribner volume using 330 board feet per cord.
(ii) In stumpage value areas 6 and 7 logs with an average scaling diameter of 8 inches and larger must be converted to Scribner volume using 470 board feet per cord. Logs having an average scaling diameter of less than 8 inches must be converted to Scribner volume using 390 board feet per cord.
(iii) A cord of Western Redcedar shake or shingle blocks must be converted to Scribner volume using 600 board feet per cord.
(iv) Firewood must be converted at a rate of 3 tons per cord.
(c)Cants or lumber from portable mills. To convert from lumber tally to Scribner volume:
(i) In stumpage value areas 1, 2, 3, 4, 5, and 9 multiply the lumber tally for the individual species by 75%, and round to the nearest one thousand board feet (MBF); or
(ii) In stumpage value areas 6 and 7 multiply the lumber tally for the individual species by 88%, and round to the nearest one thousand board feet (MBF).
(d)Log scale conversion. Timber harvested in stumpage value areas 1, 2, 3, 4, 5, and 9 and which has been scaled by methods and procedures published in the "Eastside Log Scaling Handbook" must have the volumes reported reduced by eighteen percent. Timber harvested in stumpage value areas 6 and 7 and which has been scaled by methods and procedures published in the "Official Log Scaling and Grading Rules" developed and authored by the Northwest log rules advisory group, must have the volumes reported increased by eighteen percent.
(e)Timber pole and piling volume tables. Harvesters of poles must use the following tables to determine the Scribner board foot volume for each pole length and class:

Total Scribner Board Foot Volume Stumpage Value Areas 1, 2, 3, 4, 5, and 9

Pole Class1

Piling Class2

Length

H6

H5

H4

H3

H2

H1

1

2

3

4

5

6

7

9

10

A

B

20

50

50

40

40

30

30

20

20

20

80

70

25

60

60

50

50

40

40

30

30

30

100

90

30

110

70

60

60

50

50

40

40

130

110

35

160

160

130

100

80

80

60

60

50

130

110

40

240

200

180

180

150

120

120

90

70

60

150

120

45

380

340

340

280

230

230

190

150

120

120

90

90

150

120

50

430

370

370

300

260

260

210

160

140

140

100

160

140

55

470

410

410

330

280

280

230

180

150

150

180

150

60

540

470

470

410

340

340

290

220

190

190

190

160

65

610

520

520

420

380

380

320

260

210

210

210

180

70

650

560

560

480

400

400

350

270

230

230

230

190

75

700

600

600

520

520

520

440

290

250

230

200

80

820

700

700

600

600

540

440

360

290

250

210

85

910

800

800

660

660

660

570

490

360

260

210

90

1080

930

930

820

820

690

590

490

400

260

220

95

1170

1000

1000

870

870

750

640

540

290

240

100

1190

1030

1030

900

900

760

660

550

310

250

105

1310

1160

1160

1000

1000

860

740

610

330

270

110

1370

1220

1220

1050

1050

910

780

650

380

300

115

1440

1280

1280

1100

1100

960

860

680

400

310

120

1660

1460

1460

1300

1300

1140

970

820

500

400

125

1840

1600

1600

1410

1410

1250

1080

930

130

1920

1680

1680

1490

1490

1310

1120

970

1 Pole class definitions taken from American National Standard specifications and dimensions for wood poles as approved August 7, 1976, under American National Standard Institute, Inc. codified ANSI 05.1-1972.

2 Piling class definitions as per American Society for Testing and Materials for "round timber piles." As the designation: D 25-58 (reapproved 1964).

Total Scribner Board Foot Volume Stumpage Value Areas 6 and 7

Pole Class1

Piling Class2

Length

H6

H5

H4

H3

H2

H1

1

2

3

4

5

6

7

9

10

A

B

20

70

60

50

50

30

30

20

20

20

90

70

25

80

70

50

50

40

40

30

30

20

100

80

30

110

90

60

60

50

50

50

40

130

110

35

190

160

140

100

100

70

60

60

50

140

100

40

240

240

200

170

120

110

100

70

70

140

100

45

390

330

330

270

270

220

180

150

110

110

80

70

150

110

50

460

390

390

340

340

280

240

190

150

150

120

190

150

55

510

430

430

370

360

300

250

190

150

150

190

150

60

610

530

530

440

440

380

310

240

200

200

240

200

65

650

570

570

490

480

410

350

280

220

220

240

200

70

750

650

650

550

470

470

410

320

260

260

260

210

75

810

700

700

600

600

500

440

340

270

270

220

80

960

830

830

710

710

610

510

420

340

220

220

85

1020

870

870

760

760

640

550

450

360

300

240

90

1110

970

970

840

840

720

620

500

420

280

280

95

1160

1010

1010

870

870

740

640

510

360

280

100

1380

1210

1210

1060

1060

910

780

650

360

280

105

1430

1250

1250

1100

1100

940

820

690

400

300

110

1580

1390

1390

1220

1220

1070

920

770

460

340

115

1660

1470

1470

1280

1280

970

810

680

470

360

120

1880

1680

1680

1480

1480

1290

1130

950

560

450

125

1910

1690

1690

1490

1490

1140

970

810

130

2170

1920

1920

1710

1710

1510

1320

1140

1 Pole class definitions taken from American National Standard specifications and dimensions for wood poles as approved August 7, 1976, under American National Standard Institute, Inc. codified ANSI 05.1-1972.

2 Piling class definitions as per American Society for Testing and Materials for "round timber piles." As the designation: D 25-58 (reapproved 1964).

Wash. Admin. Code § 458-40-680

Amended by WSR 19-02-068, Filed 12/28/2018, effective 1/1/2019

Statutory Authority: RCW 82.32.300, 82.01.060(2), 84.33.096, and 84.33.091. 12-14-065, § 458-40-680, filed 6/29/12, effective 7/1/12. Statutory Authority: RCW 82.32.300, 82.01.060(2), and 84.33.096. 06-02-007, § 458-40-680, filed 12/22/05, effective 1/22/06; 05-08-070, § 458-40-680, filed 3/31/05, effective 5/1/05; 03-22-099, § 458-40-680, filed 11/5/03, effective 12/6/03. Statutory Authority: RCW 82.32.300 and 84.33.096. 00-24-068, § 458-40-680, filed 12/1/00, effective 1/1/01. Statutory Authority: RCW 82.32.330, 84.33.096 and 84.33.120. 96-02-056, § 458-40-680, filed 12/29/95, effective 1/29/96. Statutory Authority: RCW 82.32.300 and 84.33.096. 95-14-084, § 458-40-680, filed 6/30/95, effective 7/31/95. Statutory Authority: Chapter 84.33 RCW. 87-02-023 (Order 86-4), § 458-40-680, filed 12/31/86.