Wash. Admin. Code § 296-876-40035

Current through Register Vol. 24-23, December 1, 2024
Section 296-876-40035 - Exposed electrical hazards

You must use ladders with nonconductive side rails where the ladder could contact uninsulated, energized electric lines or equipment. Metal ladders or other ladders specifically designed to permit grounding or dissipation of static electricity may be used around high-static electrical fields if all of the following are met:

(1) Using nonconductive ladders would present a greater hazard than using conductive ladders.
(2) Ladders are prominently marked and identified as being conductive.
(3) Ladders are grounded when used near energized lines or equipment.

Note: Examples of ladders with conductive side rails are metal ladders, and wood or reinforced plastic ladders with metal side rail reinforcement.

Wash. Admin. Code § 296-876-40035

Amended by WSR 14-09-095, filed 4/22/14, effective 7/1/2014

Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. 05-20-068, § 296-876-40035, filed 10/4/05, effective 1/1/06.