Wash. Admin. Code § 296-855-30010

Current through Register Vol. 24-20, October 15, 2024
Section 296-855-30010 - Periodic exposure monitoring

Exemption: Periodic employee exposure monitoring is not required if exposure monitoring results conducted to fulfill requirements in Exposure evaluation, WAC 296-855-20050, are below the action level (AL).

You must obtain employee exposure monitoring results according to the frequency specified in Table 2, Periodic Exposure Evaluation Frequencies.

Note: * If you documented that one work shift consistently has higher exposure monitoring results than another for a particular operation, then you may limit sample collection to the work shift with higher exposures and use those results to represent all employees performing the operation on other shifts.

Table 2 Periodic Exposure Evaluation Frequencies

If employee exposure monitoring results:Then:
Are between the:

* Action level (AL) of 0.5 parts per million (ppm);

AND

Conduct additional exposure monitoring at least every 6 months.
* TWAg of 1 ppm
Are above the TWA8;

OR

Above the STEL

Conduct additional exposure monitoring at least every 3 months.

Have been obtained at least every 3 months;

AND

Have 2 consecutive monitoring results, taken at least 7 days apart, showing 8-hour employee exposure monitoring results that have dropped below the TWA8, but remain at or above the AL

You may decrease your evaluation frequency for the TWA8 to every 6 months.
Have 2 consecutive evaluations, taken at least 7 days apart, showing 8-hour employee exposure monitoring results that have dropped below the AL and STEL You may stop periodic exposure evaluations.

Wash. Admin. Code § 296-855-30010

Amended by WSR 18-22-116, Filed 11/6/2018, effective 12/7/2018

Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. 05-17-168, § 296-855-30010, filed 8/23/05, effective 1/1/06.