DO NOT supply compressed oxygen to SCBAs or air-line respirators that previously used compressed air.
Note: | Compressed air leaves residues containing hydrocarbons such as oil or grease. Fire or explosion can occur if compressed oxygen makes contact with these residues. |
Note: | Respiratory equipment NOT designed for oxygen service or distribution can create fire or explosion hazards in oxygen concentrations higher than 23.5%. |
Note: | 1. Use only cylinders marked ( with serial number, cylinder pressure, DOT exemption number, and test dates) according to these DOT regulations. |
2. To find any Code of Federal Regulations (C.F.R.) visit: www.access.gpo.gov. |
Wash. Admin. Code § 296-842-20010
Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060 and chapter 49.17 RCW. 12-24-071, § 296-842-20010, filed 12/4/12, effective 1/4/13. Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. 07-05-072, § 296-842-20010, filed 2/20/07, effective 4/1/07; 03-20-114, § 296-842-20010, filed 10/1/03, effective 1/1/04.