Exception: | See (b) of this subsection. For the installation of this joist: (i) A vertical stabilizer plate must be provided on each column for steel joists. The plate must be a minimum of 6 inch by 6 inch (152 mm by 152 mm) and must extend at least 3 inches (76 mm) below the bottom chord of the joist with a 13/16-inch (21 mm) hole to provide an attachment point for guying or plumbing cables. (ii) The bottom chords of steel joists at columns must be stabilized to prevent rotation during erection. (iii) You must not release hoisting cables until the seat at each end of the steel joist is field-bolted, and each end of the bottom chord is restrained by the column stabilizer plate. |
* Provide stability equivalent to (a) of this subsection;
* Be designed by a qualified person;
* Be shop installed; and
* Be included in the erection drawings.
Table A-Erection of Bridging for Short Span Joists
Joist | Span | Joist | Span | Joist | Span | ||
8L1 | NM | 22K10 | 40-0 | 14KCS1 | NM | ||
10K1 | NM | 22K11 | 40-0 | 14KCS2 | NM | ||
12K1 | 23-0 | 24K4 | 36-0 | 14KCS3 | NM | ||
12K3 | NM | 24K5 | 38-0 | 16KCS2 | NM | ||
12K5 | NM | 24K6 | 39-0 | 16KCS3 | NM | ||
14K1 | 27-0 | 24K7 | 43-0 | 16KCS4 | NM | ||
14K3 | NM | 24K8 | 43-0 | 16KCS5 | NM | ||
14K4 | NM | 24K9 | 44-0 | 18KCS2 | 35-0 | ||
14K6 | NM | 24K10 | NM | 18KCS3 | NM | ||
16K2 | 29-0 | 24K12 | NM | 18KCS4 | NM | ||
16K3 | 30-0 | 26K5 | 38-0 | 18KCS5 | NM | ||
16K4 | 32-0 | 26K6 | 39-0 | 20KCS2 | 36-0 | ||
16K5 | 32-0 | 26K7 | 43-0 | 20KCS3 | 39-0 | ||
16K6 | NM | 26K8 | 44-0 | 20KCS4 | NM | ||
16K7 | NM | 26K9 | 45-0 | 20KCS5 | NM | ||
16K9 | NM | 26K10 | 49-0 | 22KCS2 | 36-0 | ||
18K3 | 31-0 | 26K12 | NM | 22KCS3 | 40-0 | ||
18K4 | 32-0 | 28K6 | 40-0 | 22KCS4 | NM | ||
18K5 | 33-0 | 28K7 | 43-0 | 22KCS5 | NM | ||
18K6 | 35-0 | 28K8 | 44-0 | 24KCS2 | 39-0 | ||
18K7 | NM | 28K9 | 45-0 | 24KCS3 | 44-0 | ||
18K9 | NM | 28K10 | 49-0 | 24KCS4 | NM | ||
18K10 | NM | 28K12 | 53-0 | 24KCS5 | NM | ||
20K3 | 32-0 | 30K7 | 44-0 | 26KCS2 | 39-0 | ||
20K4 | 34-0 | 30K8 | 45-0 | 26KCS3 | 44-0 | ||
20K5 | 34-0 | 30K9 | 45-0 | 26KCS4 | NM | ||
20K6 | 36-0 | 30K10 | 50-0 | 26KCS5 | NM | ||
20K7 | 39-0 | 30K11 | 52-0 | 28KCS2 | 40-0 | ||
20K9 | 39-0 | 30K12 | 54-0 | 28KCS3 | 45-0 | ||
20K10 | NM | 10KCS1 | NM | 28KCS4 | 53-0 | ||
22K4 | 34-0 | 10KCS2 | NM | 28KCS5 | 53-0 | ||
22K5 | 35-0 | 10KCS3 | NM | 30KCS3 | 45-0 | ||
22K6 | 36-0 | 12KCS1 | NM | 30KCS4 | 54-0 | ||
22K7 | 40-0 | 12KCS2 | NM | 30KCS5 | 54-0 | ||
22K9 | 40-0 | 12KCS3 | NM |
NM = Diagonal bolted bridging not mandatory for joists under 40 feet.
Table B-Erection Bridging for Long Span Joists
Joist | Span | Joist | Span | |
18LH02 | 33-0 | 28LH06 | 42-0 | |
18LH03 | NM | 28LH07 | NM | |
18LH04 | NM | 28LH08 | NM | |
18LH05 | NM | 28LH09 | NM | |
18LH06 | NM | 28LH10 | NM | |
18LH07 | NM | 28LH11 | NM | |
18LH08 | NM | 28LH12 | NM | |
18LH09 | NM | 28LH13 | NM | |
20LH02 | 33-0 | 32LH06 | 47-0 through 60-0 | |
20LH03 | 38-0 | 32LH07 | 47-0 through 60-0 | |
20LH04 | NM | 32LH08 | 55-0 through 60-0 | |
20LH05 | NM | 32LH09 | NM through 60-0 | |
20LH06 | NM | 32LH10 | NM through 60-0 | |
20LH07 | NM | 32LH11 | NM through 60-0 | |
20LH08 | NM | 32LH12 | NM through 60-0 | |
20LH09 | NM | 32LH13 | NM through 60-0 | |
20LH10 | NM | 32LH14 | NM through 60-0 | |
24LH03 | 35-0 | 32LH15 | NM through 60-0 | |
24LH04 | 39-0 | 36LH07 | 47-0 through 60-0 | |
24LH05 | 40-0 | 36LH08 | 47-0 through 60-0 | |
24LH06 | 45-0 | 36LH09 | 57-0 through 60-0 | |
24LH07 | NM | 36LH10 | NM through 60-0 | |
24LH08 | NM | 36LH11 | NM through 60-0 | |
24LH09 | NM | 36LH12 | NM through 60-0 | |
24LH10 | NM | 36LH13 | NM through 60-0 | |
24LH11 | NM | 36LH14 | NM through 60-0 | |
28LH05 | 42-0 | 36LH15 | NM through 60-0 |
NM = Diagonal bolted bridging not mandatory for joists under 40 feet.
Wash. Admin. Code § 296-155-709
Statutory Authority: RCW 49.17.010, [49.17].040, and[49.17].050 . 02-13-115, § 296-155-709, filed 6/19/02, effective 9/1/02.