* All control mechanisms for maladjustments;
* Control and drive mechanism for excessive wear of components and contamination by lubricants, water or other foreign matter;
* Safety devices, including boom angle indicators, boom stops, boom kick out devices, anti-two block devices, and load moment indicators where required;
* Air, hydraulic, and other pressurized lines for deterioration or leakage, particularly those which flex in normal operation;
* Hooks and latches for deformation, chemical damage, cracks, or wear;
* Wire rope reeving for compliance with hoisting equipment manufacturer's specifications;
* Electrical apparatus for malfunctioning, signs of excessive deterioration, dirt, or moisture accumulation;
* Hydraulic system for proper fluid level;
* Tires for proper inflation and condition;
* Ground conditions around the hoisting equipment for proper support, including ground settling under and around outriggers, ground water accumulation, or similar conditions;
* The hoisting equipment for level position; and
* The hoisting equipment for level position after each move and setup.
* A multiple lift rigging assembly is used;
* A multiple lift is only permitted when specifically within the manufacturer's specifications and limitations;
* A maximum of 5 members are hoisted per lift;
Exception: | Bundles of decking must not be lifted using the multiple lift rigging procedure, even though they meet the definition of structural members in WAC 296-155-702. |
* Only beams and similar structural members are lifted; and
* All employees engaged in the multiple lift have been trained in these procedures in accordance with WAC 296-155-717(3)(a).
* The rated capacity of the hoisting equipment specified in the hoisting equipment load charts; and
* The rigging capacity specified in the rigging-rating chart.
* Attached at their center of gravity and maintained reasonably level;
* Rigged from top down; and
* Rigged at least 7 feet (2.1 m) apart.
Wash. Admin. Code § 296-155-704
Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060 and chapter 49.17 RCW, and 29 C.F.R. 1926, Subpart CC. 13-02-068, § 296-155-704, filed 12/31/12, effective 2/1/13. Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.440, 49.17.060, and 29 C.F.R. 1926, Subpart CC. 12-01-086, § 296-155-704, filed 12/20/11, effective 2/1/12. Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060 and chapter 49.17 RCW. 10-22-105, § 296-155-704, filed 11/2/10, effective 1/1/11. Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060. 06-05-027, § 296-155-704, filed 2/7/06, effective 4/1/06. Statutory Authority: RCW 49.17.010, [49.17].040, and[49.17].050 . 02-13-115, § 296-155-704, filed 6/19/02, effective 9/1/02.