Figure 39 Block Load Factor Multipliers |
Example: Load = 1,000 lb | ||
Line Pull: 1,000 lb / 2 = 500 lb | ||
Load Block "C" = 500 lb x 2 = 1,000 lb | ||
(line pull x factor for 0 deg. angle) | ||
Load Block "D" = 500 lb x 1.87 + 500 lb = 1,435 lb | ||
(line pull x factor for 40 deg. angle + dead-end load) | ||
Load Block "E" = 500 lb x 0.84 = 420 lb | ||
(line pull x factor for 130 deg. angle) | ||
Load Block "F" = 500 lb x 1.41 = 705 lb | ||
(line pull x factor for 90 deg. angle) |
Wash. Admin. Code § 296-155-56125
Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.440, 49.17.060, and 29 C.F.R. 1926, Subpart CC. 12-01-086, § 296-155-56125, filed 12/20/11, effective 2/1/12.