Note: | See qualified rigger requirements located in WAC 296-155-53306 of this part. |
Table 11
Rigging Hardware Inspection/Removal Criteria
For all hardware, inspect for the following: |
Missing or illegible identification. |
Indications of heat damage, including weld spatter or arc strikes. |
Excessive pitting or corrosion. |
Load bearing components that are: * Bent; * Twisted; * Distorted; * Stretched; * Elongated; * Cracked; * Broken. |
Excessive nicks or gouges. |
10% reduction of the original or catalog dimension at any point. |
Excessive thread damage or wear, where applicable. |
Evidence of unauthorized welding or modification. |
Any other conditions that cause doubt as to the safety of continued use. |
On shackles, also inspect for incomplete pin engagement. |
On swivels and swivel hoist rings, check for lack of ability to freely rotate or pivot. |
On compression hardware, also check for: Unauthorized replacement components; Insufficient number of wire rope clips; Improperly tightened wire rope clips; Damaged wire rope; |
Indications of wire rope slippage; Improper assembly. |
On swivels, check for loose or missing nuts, bolts, cotter pins, snap rings, or other fasteners and retaining devices. |
On blocks check for: * Loose or missing nuts, bolts, cotter pins, snap rings, or other fasteners and retaining devices; * Misalignment or wobble in sheaves; * Excessive sheave groove corrugation or wear. |
Wash. Admin. Code § 296-155-55600
Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060 and chapter 49.17 RCW, and 29 C.F.R. 1926, Subpart CC. 13-02-068, § 296-155-55600, filed 12/31/12, effective 2/1/13. Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.440, 49.17.060, and 29 C.F.R. 1926, Subpart CC. 12-01-086, § 296-155-55600, filed 12/20/11, effective 2/1/12.