Wash. Admin. Code § 296-155-53905

Current through Register Vol. 24-23, December 1, 2024
Section 296-155-53905 - Tower cranes - Additional inspection criteria
(1) In addition to the requirements in WAC 296-155-53405, the following additional items must be included:
(a) Tower (mast) bolts and other structural bolts (for loose or dislodged condition) from the base of the tower crane up or, if the crane is tied to or braced by the structure, those above the upper-most brace support.
(b) The upper-most tie-in, braces, floor supports and floor wedges where the tower crane is supported by the structure, for loose or dislodged components.
(2) Annual. In addition to the items that must be inspected under WAC 296-155-53405(5), all turntable and tower bolts must be inspected for proper condition and torque.

Wash. Admin. Code § 296-155-53905

Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.440, 49.17.060, and 29 C.F.R. 1926, Subpart CC. 12-01-086, § 296-155-53905, filed 12/20/11, effective 2/1/12.