Table 24 Close Proximity Lifting Magnet Frequent Inspection
Inspect for: | How often: |
Structural and suspension members for: | |
* Deformation. | * Normal service - Monthly. |
* Cracks. " Excessive wear on any part of the lifting magnet. | * Heavy service - Weekly to monthly. " Severe service - Daily to weekly. |
The lifting magnet face for: " Foreign materials. " Smoothness. | * Special or infrequent service - As recommended by a qualified person before and after each occurrence. |
Condition of lifting bail or sling suspension. | " Before using, when a lifting magnet has been idle for more than one month. |
Condition and operation of control handle. | |
Condition and operation of indicators and meters, if applicable. | |
Electrical conductors, if applicable, that are visible without disassembly for: " Loose connections. " Continuity. " Corrosion. | |
* Damage to insulation. | |
Battery operated electromagnets for: " Proper level of battery electrolyte. " Corrosion of battery posts or connectors. | |
Cracked housings, welds, and loose bolts. | |
Legible labels and marking. |
Note: | * Normal service means service that involves operation with various weights within the rated load limit, averaging less than 65% of rated load limits. |
* Heavy service means service that involves operation within the rated load limit, that exceeds the limits of normal service. | |
* Severe service means service that involves normal or heavy service with abnormal operating conditions. |
Table 25 Close Proximity Lifting Magnet Periodic Inspection
Inspect for: | How often: |
Members, fasteners, locks, switches, warning labels, and lifting parts for: " Deformation. " Wear. " Corrosion. | " Normal service for equipment in place - Yearly. " Heavy service, unless external conditions indicate that disassembly should be done to permit detailed inspection - Quarterly. " Severe service - Monthly. |
All electrical components, including controllers, battery, external power supply, power disconnects, meters, indicators, and alarms for: " Proper operation. | |
* Condition. | " Special or infrequent service - As recommended by a qualified person before the first occurrence and as directed by the qualified person for any subsequent occurrences. |
Lifting magnet coil must be tested for: " Ohmic and ground readings compared to manufacturer's standards. |
Note: | * Normal service means service that involves operation with various weights within the rated load limit, averaging less than 65% of rated load limits. |
* Heavy service means service that involves operation within the rated load limit, that exceeds the limits of normal service. | |
* Severe service means service that involves normal or heavy service with abnormal operating conditions. |
Wash. Admin. Code § 296-155-34015
Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, 49.17.060 and chapter 49.17 RCW, and 29 C.F.R. 1926, Subpart CC. 13-02-068, § 296-155-34015, filed 12/31/12, effective 2/1/13.