The following sections and subsections of Title 40 Code of Federal Regulations (C.F.R.) Part 141 National Primary Drinking Water Regulations and Part 143 National Secondary Drinking Water Regulations revised as of July 1, 2016, are adopted by reference:
141.2 Definitions. Only those definitions listed as follows:
Action level; | |
Corrosion inhibitor; | |
Effective corrosion inhibitor residual; | |
Enhanced coagulation; | |
Enhanced softening; | |
First draw sample; | |
Haloacetic acids (five) (HAA5); | |
Large water system; | |
Lead service line; | |
Maximum residual disinfectant level (MRDL); | |
Maximum residual disinfectant level goal (MRDLG); | |
Medium-size water system; | |
Optimal corrosion control treatment; | |
Service line sample; | |
Single family structure; | |
Small water system; | |
Specific ultraviolet absorption (SUVA); and | |
Total Organic Carbon (TOC). | |
141.13 | Maximum contaminant levels for turbidity. |
141.22 | Turbidity sampling and analytical requirements. |
141.23(a) - excluding (i)(2) | 141.23(j), Inorganic chemical sampling. |
141.23(m) - | 141.23(o) |
141.24(a) - | 141.24(d), Organic chemicals ((other than total trihalomethanes)). sampling and analytical requirements. |
141.24(f)(1)- 141.24 (f)(15), | |
141.24 (f)(18), 141.24 (f)(19), | |
141.24 (f)(21), 141.24 (f)(22) | |
141.24 (g)(1) - 141.24 (g)(9), | |
141.24 (g)(12) - 141.24 (g)(14), | |
141.24 (h)(1) - 141.24 (h)(ll), | |
141.24 (h)(14) - 141.24 (h)(17) | |
141.24 (h)(20) | |
141.25(a), | 141.25 (c) - (d). Analytical methods for radioactivity. |
141.26 | Monitoring frequency and compliance for radionuclides in community water systems. |
141.31(d) | Reporting requirements. |
141.33(e) | Record maintenance. |
141.40 | Monitoring requirements for unregulated contaminants. |
141.61 | Maximum contaminant levels for organic contaminants. |
141.62, excluding (b) | Maximum contaminant levels for inorganic contaminants. |
141.63(e) | Maximum contaminant levels (MCLs) for microbiological contaminants. |
141.64 | Maximum contaminant levels for disinfection byproducts. |
141.65(c) | Maximum Residual Disinfectant Levels. |
141.66 | Maximum contaminant levels for radionu-chdes. |
Control of Lead and Copper | |
141.80, excluding (c)(3)(v) | General requirements. |
141.81 | Apphcability of corrosion control treatment steps to small, medium-size and large water systems. |
141.82(a) - | 141.82(h) Description of corrosion control treatment requirements. |
141.83 | Source water treatment requirements. |
141.84 | Lead service line replacement requirements. |
141.85 | Pubhc education and supplemental monitoring requirements. |
141.86 (a) -(f) | Monitoring requirements for lead and copper in tap water |
141.87 | Monitoring requirements for water quality parameters. |
141.88 | Monitoring requirements for lead and copper in source water |
141.89 | Analytical methods |
141.90, excluding (a)(4) | Reporting requirements. |
141.91 | Recordkeeping requirements. |
Disinfectants and Disinfection Byproducts (D/DBP) | |
141.130 | General requirements. |
141.131 | Analytical requirements. |
141.132, excluding (c)(l)(i) | Monitoring requirements. |
141.133 | Comphance requirements. |
141.134 | Reporting and recordkeeping requirements. |
141.135 | Treatment technique for control of disinfection byproduct precursors. |
Subpart O - Consumer Confidence Reports 141.153(h)(6) Contents of the reports, and (7) | |
Enhanced Filtration and Disinfection - Systems Serving 10,000 or More People | |
141.175(b) | Reporting and recordkeeping requirements. |
Subpart Q - | Public Notification of Drinking Water Violations |
141.201, excluding (3)(ii) of Table 1 | General Public notification requirements. |
141.202, excluding (3) of Tablet | Tier 1 Public Notice - Form, maimer, and frequency of notice. |
141.203 | Tier 2 Public Notice - Form, manner, and frequency of notice. |
141.204 | Tier 3 Public Notice - Form, manner, and frequency of notice. |
141.205 | Content of the public notice. |
141.206 | Notice to new billing units or new customers. |
141.207 | Special notice of the availability of unregulated contaminant monitoring results. |
141.208 | Special notice for exceedances of the SMCL for fluoride. |
141.211 | Special notice for repeated failure to conduct monitoring of the source water for Cryptospo-ridium and for failure to determine bin classification or mean Cryptosporid-ium level. |
Appendix A to Subpart Q of Part 141 - NPDWR violations and other situations requiring public notice | |
Appendix B to Subpart Q of Part 141 - Standard health effects language for public notification | |
Appendix C to Subpart Q of Part 141- List of acronyms used in public notification regulation | |
141.400 | General requirements and applicability. |
141.402(c) | Groundwater source microbial monitoring and analytical methods. |
141.403 (b)(3)(i) through (iii) | Treatment technique requirements for ground-water systems. |
Subpart T - Enhanced Filtration and Disinfection - Systems Serving Fewer Than 10,000 People | |
141.530 -141.544 | Disinfection profile and benchmark. |
141.563 | What follow-up action is my system required to take based on continuous turbidity monitoring? |
141.570, excluding (c) | What does Sub-part T require that my system report to the state? |
Subpart U - Initial Distribution System Evaluations | |
141.600 -141.605 | Initial distribution system evaluations. |
Subpart V - Stage 2 Disinfection Byproducts Requirements | |
141.620 -141.629, excluding 624 | Stage 2 Disinfection Byproducts Requirements. |
Subpart W - Enhanced Treatment for Cryptosporidium141.700-722 Enhanced Treatment for Cryptosporidium | |
Subpart Y - Revised Total Coliform Rule | |
141.852 | Analytical methods and laboratory certification. |
141.860 (c) - (d) | Violations |
Part 143 - National Secondary Drinking Water Regulations | |
143.1 | Purpose. |
143.2 | Definitions. |
143.3 | Secondary maximum contaminant levels. |
143.4 | Monitoring. |
Copies of the incorporated sections and subsections of Title 40 C.F.R. are available from the Department of Health online at: http://www/doh.wa.gov/CommunityandEnvironment/DrinkingWater/RegulationandCompliance/ Rules, or P.O. Box 47822, Olympia, Washington 98504-7822, or by calling the department's drinking water hotline at 800-521-0323.
Wash. Admin. Code § 246-290-025
Statutory Authority: RCW 43.20.050(2) and 70.119A.080. 11-17-062, § 246-290-025, filed 8/15/11, effective 10/1/11. Statutory Authority: RCW 43.20.050 and 70.119A.080. 10-20-068, § 246-290-025, filed 9/29/10, effective 11/1/10. Statutory Authority: RCW 43.20.050. 09-21-045, § 246-290-025, filed 10/13/09, effective 1/4/10. Statutory Authority: RCW 70.119A.180 and 43.20.050. 08-03-061, § 246-290-025, filed 1/14/08, effective 2/14/08. Statutory Authority: RCW 43.20.050 and 70.119A.080. 04-04-056, § 246-290-025, filed 1/30/04, effective 3/1/04. Statutory Authority: RCW 43.20.050(2) and (3) and RCW 70.119A.080. 03-08-037, § 246-290-025, filed 3/27/03, effective 4/27/03. Statutory Authority: RCW 43.02.050 [43.20.050]. 99-07-021, § 246-290-025, filed 3/9/99, effective 4/9/99. Statutory Authority: RCW 43.20.050. 94-14-001, § 246-290-025, filed 6/22/94, effective 7/23/94.