Table I
Testing Requirements for Proprietary Treatment Products | |
Treatment Component/Sequence Category | Required Testing Protocol |
Category 1 Designed to treat septic tank effluent anticipated to be equal to or less than treatment level E. | NSF/ANSI 40-Residential Wastewater Treatment Systems versions dated between January 2009 and May 31, 2021 |
Category 2 Designed to treat effluent or sewage with sewage quality parameters anticipated to be greater than treatment level E. (Such as at restaurants, grocery stores, mini-marts, group homes, medical clinics, residences, etc.) | EPA Method 1664, Revision B (February 2010) |
Category 3 Black water component of residential sewage (such as composting * and incinerating ** toilets). | NSF/ANSI 41: Non-Liquid Saturated Treatment Systems Versions dated between February 2011 and May 31, 2021 **NSF Protocol P157 Electrical Incinerating Toilets -Health and Sanitation (April 2000) |
Total Nitrogen Reduction in Categories 1 & 2 (Above) | NSF/ANSI 245: Residential Wastewater Treatment Systems - Nitrogen Reduction (Versions dated between January 2018 and May 31, 2021) |
Table II
Test Results Reporting Requirements for Proprietary Treatment Products | |||
Treatment Component/Sequence Category | Testing Results Reported | ||
Category 1 Designed to treat septic tank effluent anticipated to be equal to or less than treatment level E. | Report the following test results of influent and effluent sampling obtained throughout the testing period for evaluation of of CBOD52, and TSS: | ||
[] Average | [] Standard Deviation | ||
[] Minimum | [] Maximum | ||
[] Median | [] Interquartile Range | ||
[] 30-day Average (for each month) | |||
For evaluation of bacteriological reduction performance. Report complete treatment component sequence testing as described in Table III, Category 1. For evaluation of performance meeting treatment level BL1: (1) Report fecal coliform test results of influent and effluent sampling by geometric mean from samples drawn within 30-day or monthly calendar periods, obtained from a minimum of three samples per week throughout the testing period. See WAC 246-272A-0130. (2) Report complete testing results for supplemental bacteriological reduction technology1 when the required treatment levels for fecal coliform in Table III, Category 1 are not met by the primary proprietary treatment product. For evaluation of performance meeting treatment level BL2 or BL3: (1) Report fecal coliform test results of influent and effluent sampling by geometric mean from samples drawn within 30-day or monthly calendar periods, obtained from a minimum of three samples per week throughout the testing period as described in WAC 246-272A-0130; or (2) Report complete testing results for supplemental bacteriological reduction technology1 when the required treatment levels for fecal coliform in Table III, Category 1 are not met by the primary proprietary treatment product. For all options, test report must also include the individual results of all samples drawn throughout the test period. | |||
Category 2 Designed to treat effluent or sewage with sewage quality parameters anticipated to be greater than treatment level E. (Such as at restaurants, grocery stores, minimarts, group homes, medical clinics, atypical residences, etc.) | Report all individual test results and full test average values of influent and effluent sampling obtained throughout the testing period for the evaluation of reduction of: CBOD5, TSS and O&G. Establish the treatment capacity of the product tested in pounds per day for CBOD5. | ||
Category 3 Black water component of residential sewage (such as composting and incinerating toilets). | Report test results on all required performance criteria according to the format prescribed in the NSF test protocol described in Table I. | ||
Total Nitrogen Reduction in Categories 1 & 2 (Above) | Report test results on all required performance criteria according to the format prescribed in the test protocol described in Table I. |
1 Test results for BOD5 may be submitted in lieu of test results for CBOD5. In these cases numerical values for CBOD5 will be determined using the following formula: (BOD5 × 0.83 = CBOD5).
2 Supplemental bacteriological reduction technology must be tested for influent/effluent fecal coliform or E. coli per WAC 246-272A-0130 (bacteriological reduction testing protocol). Supplemental fecal coliform or E. coli reducing technologies will be rated for log base 10 removal of fecal coliform or E. coli. The lowest 30-day geometric mean will be used to rate reduction level. The highest monthly geometric mean for treatment technology fecal coliform or E. coli reduction will be used as the baseline value for review.
Table III
Product Performance Requirements for Proprietary Treatment Products | |||||||
Treatment Component/Sequence Category | Product Performance Requirements | ||||||
Category 1 Designed to treat effluent anticipated to be equal to or less than treatment level E. | Treatment System Performance Testing Levels | ||||||
Level | Parameters | ||||||
CBOD5 mg/L | TSS mg/L | O&G mg/L | FC cfu/100 mL | TN mg/L | E. coli cfu/100 mL | ||
A | 10 | 10 | ---- | ---- | ---- | ---- | |
B | 15 | 15 | ---- | ---- | ---- | ---- | |
C | 25 | 30 | ---- | ---- | ---- | ---- | |
BL1 | ---- | 200 | ---- | 126 | |||
BL2 | ---- | ---- | ---- | 1,000 | ---- | ---- | |
BL3 | ---- | ---- | ---- | 50,000 | ---- | ---- | |
E | 228 | 80 | 20 | ---- | ---- | ---- | |
N | ---- | ---- | ---- | ---- | 30 (or 50% reduction based on mass loading as required in WAC 246-272A-0320) | ---- | |
Values for Levels A - C are 30-day values (averages for CBOD5, TSS, and geometric mean for FC.) All 30-day averages throughout the test period must meet these values in order to be registered at these levels. Values for Levels E and N are derived from full test averages. | |||||||
Category 2 Designed to treat high-strength sewage when septic tank effluent is anticipated to be greater than treatment level E. (Such as at restaurants, grocery stores, minimarts, group homes, medical clinics, residences, etc.) | All of the following requirements must be met: (1) All full test averages must meet Level E; and (2) Establish the treatment capacity of the product tested in pounds per day for CBOD5. | ||||||
Category 3 Black water component of residential sewage (such as composting and incinerating toilets). | Test results must meet the performance requirements established in the NSF test protocol. | ||||||
Total Nitrogen Reduction in Categories 1 & 2 (Above) | Test results must establish product performance effluent quality meeting Level N, when presented as the full test average. |
Wash. Admin. Code § 246-272A-0110
Statutory Authority: RCW 43.20.050. 05-15-119, § 246-272A-0110, filed 7/18/05, effective 9/15/05.