1.0Calculate Heat Input Capacity

Click here to view image

2.0Methane Gas Generation

CH4 Generation is calculated using the following equation:

Click here to view image

3.0To Convert Methane Generated from Mg of CH4 to SCFM

Click here to view image

4.0Define ANDOC%

Click here to view image

5.0Define ANDOC

Click here to view image

6.0Calculate ANDOCyear-end

Click here to view image

Table 1 lists the accepted constant values for the anaerobic decomposition rate ("k").

Table 1: K Values

K for Average Rainfall (Inches/Year)

Inches Rain

<20

20-40

>40

K Value

0.02

0.038

0.057