Wash. Admin. Code § 16-201-070

Current through Register Vol. 24-17, September 1, 2024
Section 16-201-070 - Secondary containment of liquid bulk fertilizers - Precipitation accumulations

Precipitation may not be allowed to accumulate in secondary containment to the point where it:

(1) Reduces the capacity of the secondary containment below one hundred ten percent of the volume of the largest storage container within the area plus the displacement of all other storage containers, appurtenances, and other items within the containment area;
(2) Increases corrosion of storage containers or appurtenances; or
(3) Impairs the stability of storage containers.

Wash. Admin. Code § 16-201-070

Statutory Authority: RCW 15.54.800. 00-23-075, § 16-201-070, filed 11/17/00, effective 12/18/00. Statutory Authority: RCW 15.54.800 and 15.58.040. 93-22-093 (Order 5018), § 16-201-070, filed 11/2/93, effective 3/1/94.