where:
ER = The VOC emissions from the noncomplying representative product, had it been reformulated.
ENC = The VOC emissions from the noncomplying representative product in its current formulation.
VOCSTD = the VOC limit specified in Table 45-3A.
VOCNC = the VOC content of the noncomplying product in its current formulation.
If a manufacturer demonstrates that this equation yields inaccurate results due to some characteristic of the product formulation or other factors, an alternative method that accurately calculates emissions may be used upon approval of the board.
9 Va. Admin. Code § 5-45-330
Statutory Authority
§ 10.1-1308 of the Code of Virginia.