"Average monthly throughput" means the average monthly amount of gasoline pumped at a gasoline dispensing facility during the two most recent consecutive calendar years or some other two-year period which is representative of normal source operation. If the board determines that no two-year period is representative of normal source operation, the board shall allow the use of an alternative period of time upon a determination by the board that it is more representative of normal source operation. Downtime, such as a full or significant shutdown of a facility's operation due to construction, shall not be included when calculating average monthly throughput.
"Begin actual construction" means initiation of permanent physical on-site construction of a new gasoline dispensing facility. This includes, but is not limited to, installation of building supports and foundations, laying of underground pipework, and construction of permanent storage structures.
"Bulk gasoline plant" means a secondary distribution point for delivering gasoline to local farms, businesses, service stations and other distribution points, where the total gasoline throughput is 20,000 gallons or less per working day, based on the daily average for the most recent 12-month period.
"Bulk gasoline terminal" means a primary distribution point for delivering gasoline to bulk plants, service stations and other distribution points, where the total gasoline throughput is greater than 20,000 gallons per working day, based on the daily average for the most recent 12-month period.
"Certified Stage II vapor recovery system" means any system certified by California Air Resources Board as having a vapor recovery or removal efficiency of at least 95%, and approved under the provisions of AQP-9, Procedures for Implementation of Regulations Covering Stage II Vapor Recovery Systems for Gasoline Dispensing Facilities (see 9VAC5-20-121) .
"Condensate" means a hydrocarbon liquid separated from natural gas which condenses due to changes in the temperature or pressure or both and remains liquid at standard conditions.
"Crude oil" means a naturally occurring mixture which consists of any combination of hydrocarbons, sulfur, nitrogen or oxygen derivatives of hydrocarbons and which is a liquid at standard conditions.
"Custody transfer" means the transfer of produced crude oil or condensate, after processing or treating or both in the producing operations, from storage tanks or automatic transfer facilities to pipelines or any other forms of transportation.
"Defective equipment" means any absence, disconnection, or malfunctioning of a Stage II vapor recovery system component required by this article including, but not limited to, the following:
"External floating roof" means a storage vessel cover in an open top consisting of a double deck or pontoon single deck which rests upon and is supported by the liquid being contained and is equipped with a closure seal or seals to close the space between the roof edge and tank shell.
"Gasoline" means any petroleum distillate having a Reid vapor pressure of four pounds per square inch or greater.
"Gasoline dispensing facility" means any site where gasoline is dispensed to motor vehicle tanks from stationary storage tanks.
"Independent small business gasoline marketer" means a person engaged in the marketing of gasoline who owns one or more gasoline dispensing facilities and is required to pay for procurement and installation of vapor recovery equipment, unless such owner:
For the purposes of this definition, "control" of a corporation means ownership of more than 50% of its stock and "control" of a partnership, joint venture or other nonstock entity means ownership of more than a 50% interest in such partnership, joint venture or other nonstock entity. The lessee of a gasoline dispensing facility, for which the owner of such outlet does not sell, trade in, or otherwise dispense any product at wholesale or retail at such outlet, shall be considered an independent small business marketer if the lessee by lease agreement with the owner is required to pay for the cost of procurement and installation of vapor recovery equipment over a reasonable period.
"Internal floating roof" means a cover or roof in a fixed roof tank which rests upon or is floated upon the liquid being contained and is equipped with a closure seal or seals to close the space between the roof edge and tank shell.
"Liquid-mounted" means a primary seal mounted so the bottom of the seal covers the liquid surface between the tank shell and the floating roof.
"Major system modification" means the replacement, repair or upgrade of 75% of a facility's Stage II vapor recovery system equipment.
"Owner" means, for the purposes of this article, any person, including bodies politic and corporate, associations, partnerships, personal representatives, trustees and committees, as well as individuals who own, lease, operate, control or supervise an operation involving the storage or transfer of petroleum liquids or both.
"Petroleum liquids" means crude oil, condensate, and any finished or intermediate products manufactured or extracted in a petroleum refinery.
"Petroleum refinery" means any facility engaged in producing gasoline, kerosene, distillate fuel oils, residual fuel oils, lubricants or other products through distillation of petroleum or through redistillation, cracking, rearrangement or reforming of unfinished petroleum derivatives.
"Refiner" means any person or entity that owns or operates a facility engaged in the production of gasoline, kerosene, distillate fuel oils, residual fuel oils, lubricants or similar products through distillation of petroleum or through redistillation, cracking, or reforming of unfinished petroleum derivatives and whose total refinery capacity (including the refinery capacity of any person or entity who controls, is controlled by or is under common control with, such refiner) is greater than 65,000 barrels per day.
"Stage II vapor recovery system" means any equipment designed and used to collect, recover, or destroy, or any combination of those, gasoline vapors displaced during the transfer of gasoline into a motor vehicle fuel tank.
"Submerged fill pipe" means any fill pipe the discharge opening of which is entirely submerged when the liquid level is six inches above the bottom of the tank; or, when applied to a tank which is loaded from the side, any fill pipe the discharge opening of which is entirely submerged when at the minimum operating level.
"Vapor-mounted" means a primary seal mounted so there is an annular vapor space underneath the seal. The annular vapor space is bounded by the bottom of the primary seal, the tank shell, the liquid surface, and the floating roof.
"Vapor tight" means capable of holding a pressure of 18 inH20 and a vacuum of 6 inH2O without sustaining a pressure change of more than 3 inH2O in five minutes.
"Waxy, heavy pour crude oil" means a crude oil with a pour point of 50°F or higher as determined by the American Society for Testing and Materials publication, "Test for Pour Point of Petroleum Oils" (see 9VAC5-20-21) .
9 Va. Admin. Code § 5-40-5210
Statutory Authority
§ 10.1-1308 of the Code of Virginia.