Current through Register Vol. 41, No. 6, November 4, 2024
Section 9VAC5-40-1840 - Standard for particulate matterA. No owner or other person shall cause or permit any material to be produced, handled, stockpiled or transported without taking measures to reduce to a minimum any particulate matter from becoming airborne. Where it is practical to measure the emission, the emission shall not exceed the limits established by Table 4-14. All such airborne particulate matter emanating from the yards, sidings or roads of such operations shall be considered fugitive dust and shall be controlled as stipulated in 9VAC5-40-1860. All crushers shall be fitted with liquid sprays or other appropriate systems which effectively limit the escape of airborne dust. Vibrating and shaker screens handling dry materials shall be enclosed or fitted with a collector system which will prevent the release of more than 0.05 grains per standard cubic foot. All feeders, elevators, conveyors, transfer points, discharge points and loading points shall be equipped with collectors, sprays or other means when necessary to minimize the escape of dust. TABLE 4-14 |
Process Weight | Maximum Allowable Emission Rate |
Lb/Hr | Tons/Hr | Lb/Hr |
100 or less | 0.05 or less | 0.551 |
200 | 0.10 | 0.877 |
400 | 0.20 | 1.40 |
600 | 0.30 | 1.83 |
800 | 0.40 | 2.22 |
1000 | 0.50 | 2.58 |
1500 | 0.75 | 3.38 |
2000 | 1.00 | 4.10 |
2500 | 1.25 | 4.76 |
3000 | 1.50 | 5.38 |
3500 | 1.75 | 5.96 |
4000 | 2.00 | 6.52 |
5000 | 2.50 | 7.58 |
6000 | 3.00 | 8.56 |
7000 | 3.50 | 9.49 |
8000 | 4.00 | 10.4 |
9000 | 4.50 | 11.2 |
10000 | 5.00 | 12.0 |
12000 | 6.00 | 13.6 |
16000 | 8.00 | 16.5 |
18000 | 9.00 | 17.9 |
20000 | 10.00 | 19.2 |
30000 | 15.00 | 25.2 |
40000 | 20.00 | 30.5 |
50000 | 25.00 | 35.4 |
60000 | 30.00 | 40.0 |
70000 | 35.00 | 41.3 |
80000 | 40.00 | 42.5 |
90000 | 50.00 | 44.6 |
120000 | 60.00 | 46.3 |
140000 | 70.00 | 47.8 |
160000 | 80.00 | 49.1 |
200000 | 100.00 | 51.3 |
1000000 | 500.00 | 69.0 |
2000000 | 1000.00 | 77.6 |
6000000 | 3000.00 | 92.7 |
B. Interpretation of emission standard in subsection A of this section shall be in accordance with 9VAC5-40-22.C. The provisions of this section shall not apply to affected facilities identified in subsection A of this section and located in AQCR 7; however, the provisions of 9VAC5-40-270 shall apply to the facilities.9 Va. Admin. Code § 5-40-1840
Derived from VR120-04-1403, eff. January 1, 1985.Statutory Authority
§§ 10.1-1307 and 10.1-1308 of the Code of Virginia.