4 Va. Admin. Code § 50-20-70

Current through Register Vol. 40, No. 22, June 17, 2024
Section 4VAC50-20-70 - Construction permits
A. Prior to preparing the complete design report for a Construction Permit, applicants may submit a preliminary design report to the department to determine if the project concept is acceptable to the department. The preliminary design report should contain, at a minimum, a general description of subdivisions 1 through 12 of subsection B of this section and subdivisions 1 and 2 of this subsection:
1. Proposed design criteria and a description of the size of the impounding structure, ground cover conditions, extent of current upstream development within the watershed and the hydraulic, hydrological and structural features, geologic conditions and the geotechnical engineering assumptions used to determine the foundation, impoundment rim stability and materials to be used.
2. Preliminary drawings of a general nature, including cross sections, plans and profiles of the impounding structure, proposed pool levels and types of spillway(s).
B. An applicant for a Construction Permit shall submit a design report. A form for the design report is available from the department (Design Report for the Construction or Alteration of Virginia Regulated Impounding Structures). The design report shall be prepared in accordance with 4VAC50-20-240. The design report is a required element of a complete application for a Construction Permit and shall include the following information:
1. Project information including a description of the proposed construction, name of the impounding structure, inventory number if available, name of the reservoir, and the purpose of the reservoir.
2. The proposed hazard potential classification in conformance with Table 1 of 4VAC50-20-50.
3. Location of the impounding structure including the city or county, number of feet or miles upstream or downstream of a highway and the highway number, name of the river or the stream, and the latitude and longitude.
4. Owner's name or representative if corporation, mailing address, residential and business telephone numbers, and other means of communication.
5. Owner's engineer's name, firm, professional engineer Virginia number, mailing address, and business telephone number.
6. Impounding structure data including type of material (earth, concrete, masonry or other) and the following design configurations:
a. Top of impounding structure (elevation);
b. Downstream toe - lowest (elevation);
c. Height of impounding structure (feet);
d. Crest length - exclusive of spillway (feet);
e. Crest width (feet);
f. Upstream slope (horizontal to vertical); and
g. Downstream slope (horizontal to vertical).
7. Reservoir data including the following:
a. Maximum capacity (acre-feet);
b. Maximum pool (elevation);
c. Maximum pool surface area (acres);
d. Normal capacity (acre-feet);
e. Normal pool (elevation);
f. Normal pool surface area (acres); and
g. Freeboard (feet).
8. Spillway data including the type, construction material, design configuration, and invert elevation for the low level drain, the principal spillway, and the emergency spillway.
9. Watershed data including drainage area (square miles); type and extent of watershed development; time of concentration (hours); routing procedure; spillway design flood used and state source; design inflow hydrograph volume (acre-feet), peak inflow (cfs), and rainfall duration (hours); and freeboard during passage of the spillway design flood (feet).
10. A description of properties located in the dam break inundation zone downstream from the site of the proposed impounding structure, including the location and number of structures, buildings, roads, utilities and other property that would be endangered should the impounding structure fail.
11. Evidence that the local government or governments have been notified of the proposal by the owner to build an impounding structure.
12. Maps showing the location of the proposed impounding structure that include: the county or city in which the proposed impounding structure would be located, the location of roads and access to the site, and the outline of the impoundment. Existing aerial photographs or existing topographic maps may be used for this purpose.
13. A report of the geotechnical investigations of the foundation soils, bedrock, or both and of the materials to be used to construct the impounding structure.
14. Design assumptions and analyses sufficient to indicate that the impounding structure will be stable during its construction and during the life of the impounding structure under all conditions of impoundment operations, including rapid filling, flood surcharge, seismic loadings, and rapid drawdown of the impoundment.
15. Evaluation of the stability of the impoundment rim area to safeguard against impoundment rim slides of such magnitude as to create waves capable of overtopping the impounding structure and evaluation of rim stability during seismic activity.
16. Design assumptions and analyses sufficient to indicate that seepage in, around, through or under the impounding structure, foundation and abutments will be reasonably and practically controlled so that internal or external forces or results thereof will not endanger the stability and integrity of the impounding structure. The design report shall also include information on graded filter design.
17. Calculations and assumptions relative to hydraulic and structural design of the spillway or spillways and energy dissipater or dissipaters. Spillway capacity shall conform to the criteria of Table 1 and 4VAC50-20-52.
18. Provisions to ensure that the impounding structure and appurtenances will be protected against unacceptable deterioration or erosion due to freezing and thawing, wind, wave action, and rain or any combination thereof.
19. Other pertinent design data, assumptions and analyses commensurate with the nature of the particular impounding structure and specific site conditions, including when required by this chapter, a plan and water surface profile of the dam break inundation zone.
20. A description of the techniques to be used to divert stream flow during construction so as to prevent hazard to life, health and property, including a detailed plan and procedures to maintain a stable impounding structure during storm events, a drawing showing temporary diversion devices, and a description of the potential impoundment during construction. Such diversion plans shall also be in accordance with applicable environmental laws.
21. A plan for project construction monitoring and quality control testing to confirm that construction materials and performance standards meet the design requirements set forth in the specifications.
22. Plans and specifications as required by 4VAC50-20-310.
23. Certification by the owner's engineer that the information provided pursuant to this subsection is true and correct in their professional judgment. Such certification shall include the engineer's signature, printed name, Virginia number, date, and the engineer's Virginia seal.
24. Owner's signature certifying receipt of the information provided pursuant to this subsection.
C. A plan of construction is a required element of a complete permit application for a Construction Permit and shall include:
1. A construction sequence with milestones.
2. Elements of the work plan that should be considered include, but are not limited to, foundation and abutment treatment, stream or river diversion, excavation and material fill processes, phased fill and compaction, testing and control procedures, construction of permanent spillway and drainage devices.
3. The erosion and sediment control plan, as approved by the local government, which minimizes soil erosion and sedimentation during all phases of construction.
4. The stormwater management plan or stormwater management facility plan, as approved by the local government, if the impounding structure is a stormwater management best management practice.
D. A Temporary Emergency Action Plan is a required element of a complete application for a Construction Permit and shall include:
1. A notification list of state and local emergency response agencies;
2. Provisions for notification of potentially affected residences and structures;
3. Construction site evacuation routes; and
4. Any other special notes particular to the project.
E. Within 120 days of receipt of a complete Construction Permit Application the board shall act on the application. If the application is not acceptable, the director shall inform the applicant within 60 days of receipt and shall explain what changes are required for an acceptable application. A complete Construction Permit Application consists of the following:
1. A final design report, submitted on the department form (Design Report for the Construction or Alteration of Virginia Regulated Impounding Structures), with attachments as needed, and certified by the owner and the owner's engineer;
2. A plan of construction that meets the requirements of subsection C of this section; and
3. A Temporary Emergency Action Plan that meets the requirements of subsection D of this section.
F. Prior to and during construction the owner shall provide the director with any proposed changes from the approved design, plans, specifications, or plan of construction. Approval shall be obtained from the director prior to the construction or installation of any changes that will affect the integrity or impounding capacity of the impounding structure.
G. The Construction Permit shall be valid for the plan of construction specified in the Construction Permit Application.
H. Construction must commence within two years after the permit is issued. If construction does not commence within two years after the permit is issued, the permit shall expire, except that the applicant may petition the board for extension of the two-year period and the board may extend such period for good cause with an appropriately updated plan of construction and Temporary Emergency Action Plan.
I. The board, the director, or both may take any necessary action consistent with the Dam Safety Act (§ 10.1-604 et seq. of the Code of Virginia) if any terms of this section or of the permit are violated, if the activities of the owner are not in accordance with the approved plans and specifications, if construction is conducted in a manner hazardous to downstream life or property, or for other cause as described in the Act.
J. Within 90 days after completion of the construction of an impounding structure, the owner shall submit:
1. A complete set of record drawings signed and sealed by a licensed professional engineer and signed by the owner:
2. A complete Record Report (Record Report for Virginia Regulated Impounding Structures) signed and sealed by a licensed professional engineer and signed by the owner that includes:
a. Project information including the name and inventory number of the structure, name of the reservoir, and whether the report is associated with a new or old structure;
b. Location of the impounding structure including the city or county, number of feet or miles upstream or downstream of a highway and the highway number, name of the river or the stream, and the latitude and longitude;
c. Owner's name or representative if corporation, mailing address, residential and business telephone numbers, and other means of communication;
d. Information on the design report, including who it was prepared by, the date of design report preparation, whether it was for new construction or for an alteration, and the permit issuance date;
e. Owner's engineer's name, firm, professional engineer Virginia number, mailing address, and business telephone number;
f. Impounding structure data including type of material (earth, concrete, masonry or other) and the following configurations:
(1) Top of impounding structure (elevation);
(2) Downstream toe - lowest (elevation);
(3) Height of impounding structure (feet);
(4) Crest length - exclusive of spillway (feet);
(5) Crest width (feet);
(6) Upstream slope (horizontal to vertical); and
(7) Downstream slope (horizontal to vertical).
g. Reservoir data including the following:
(1) Maximum capacity (acre-feet);
(2) Maximum pool (elevation);
(3) Maximum pool surface area (acres);
(4) Normal capacity (acre-feet);
(5) Normal pool (elevation);
(6) Normal pool surface area (acres); and
(7) Freeboard (feet).
h. Spillway data including the type, construction material, design configuration, and invert elevation for the low level drain, the principal spillway, and the emergency spillway; a description of the low level drain and principal spillway including dimensions, trash guard information, and orientation of intake and discharge to impounding structure if looking downstream; and a description of the emergency spillway including dimensions and orientation to impounding structure if looking downstream;
i. Watershed data including drainage area (square miles); type and extent of watershed development; time of concentration (hours); routing procedure; spillway design flood used and state source; design inflow hydrograph volume (acre-feet), peak inflow (cfs), and rainfall duration (hours); and freeboard during passage of the spillway design flood (feet);
j. Impounding structure history including the date construction was completed, who it was designed by and the date, who it was built by and the date, who performed inspections and dates, description of repairs, and confirmation as to whether the impounding structure has ever been overtopped;
k. A narrative describing the impounding structure procedures for operation, maintenance, filling, emergency action plan implementation, and structure evaluation;
l. A narrative describing the hydraulic and hydrologic data on the spillway design flood, hydrologic records, flood experience, flood potential, reservoir regulation, and comments or recommendations regarding these attributes;
m. A narrative describing stability of the foundation and abutments, embankment materials, and a written evaluation of each;
n. A complete set of record drawings signed and sealed by a licensed professional engineer and signed by the owner;
o. Certification by the owner's engineer that the information provided pursuant to subdivision J 2 of this section is true and correct in their professional judgment. Such certification shall include the engineer's signature, printed name, Virginia number, date, and the engineer's Virginia seal; and
p. Owner's signature certifying receipt of the information provided pursuant to subdivision J 2 of this section.
3. Certification from the licensed professional engineer who has monitored construction of the impounding structure during construction that, to the best of the engineer's judgment, knowledge and belief, the impounding structure and its appurtenances were constructed in conformance with the plans, specifications, drawings and other requirements approved by the board;
4. Operation and Maintenance Certificate Application (Operation and Maintenance Certificate Application for Virginia Regulated Impounding Structures) in accordance with 4VAC50-20-105; and
5. Emergency Action Plan or Emergency Preparedness Plan in accordance with 4VAC50-20-175 or 4VAC50-20-177.
K. Upon completion of construction, the impoundment may be filled upon board issuance of an Operation and Maintenance Certificate.

4 Va. Admin. Code § 50-20-70

Derived from VR625-01-00 § 2.2, eff. February 1, 1989; amended, Virginia Register Volume 18, Issue 14, eff. July 1, 2002; Volume 24, Issue 25, eff. September 26, 2008.

Statutory Authority

§ 10.1-605 of the Code of Virginia.