4 Va. Admin. Code § 50-20-40

Current through Register Vol. 40, No. 22, June 17, 2024
Section 4VAC50-20-40 - Hazard potential classifications of impounding structures
A. Impounding structures shall be classified in one of three hazard classifications as defined in subsection B of this section and Table 1.
B. For the purpose of this chapter, hazards pertain to potential loss of human life or damage to the property of others downstream from the impounding structure in event of failure or faulty operation of the impounding structure or appurtenant facilities. Hazard potential classifications of impounding structures are as follows:
1. High Hazard Potential is defined where an impounding structure failure will cause probable loss of life or serious economic damage. "Probable loss of life" means that impacts will occur that are likely to cause a loss of human life, including but not limited to impacts to residences, businesses, other occupied structures, or major roadways. Economic damage may occur to, but not be limited to, building(s), industrial or commercial facilities, public utilities, major roadways, railroads, personal property, and agricultural interests. "Major roadways" include, but are not limited to, interstates, primary highways, high-volume urban streets, or other high-volume roadways, except those having an AADT volume of 400 vehicles or less in accordance with 4VAC50-20-45.
2. Significant Hazard Potential is defined where an impounding structure failure may cause the loss of life or appreciable economic damage. "May cause loss of life" means that impacts will occur that could cause a loss of human life, including but not limited to impacts to facilities that are frequently utilized by humans other than residences, businesses, or other occupied structures, or to secondary roadways. Economic damage may occur to, but not be limited to, building(s), industrial or commercial facilities, public utilities, secondary roadways, railroads, personal property, and agricultural interests. "Secondary roadways" include, but are not limited to, secondary highways, low-volume urban streets, service roads, or other low-volume roadways, except those having an AADT volume of 400 vehicles or less in accordance with 4VAC50-20-45.
3. Low Hazard Potential is defined where an impounding structure failure would result in no expected loss of life and would cause no more than minimal economic damage. "No expected loss of life" means no loss of human life is anticipated.
C. To support the appropriate hazard potential classification, dam break analysis shall be conducted by the owner's engineer or the department in accordance with one of the following alternatives and utilizing procedures set out in 4VAC50-20-54.
1. The owner of an impounding structure that does not currently hold a regular or conditional certificate from the board, or the owner of an impounding structure that is already under certificate but the owner believes that a condition has changed downstream of the impounding structure that may reduce its hazard potential classification, may request in writing that the department conduct a simplified dam break inundation zone analysis to determine whether the impounding structure has a low hazard potential classification. The owner shall pay a fee to the department in accordance with 4VAC50-20-395 for conducting each requested analysis. The department shall address requests in the order received and shall strive to complete analysis within 90 days; or
2. The owner may propose a hazard potential classification that shall be subject to approval by the board. To support the proposed hazard potential classification, an analysis shall be conducted by the owner's engineer and submitted to the department. The hazard potential classification shall be certified by the owner.
D. Findings of the analysis conducted pursuant to subsection C of this section shall result in one of the following actions:
1. For findings by the department resulting from analyses conducted in accordance with subdivision C 1 of this section:
a. If the department finds that the impounding structure appears to have a low hazard potential classification, the owner may be eligible for general permit coverage in accordance with 4VAC50-20-103.
b. If the department finds that the impounding structure appears to have a high or significant hazard potential classification, the owner's engineer shall provide further analysis in accordance with the procedures set out in 4VAC50-20-54 and this chapter. The owner may be eligible for grant assistance from the Dam Safety, Flood Prevention and Protection Assistance Fund in accordance with Article 1.2 (§ 10.1-603.16 et seq.) of Chapter 6 of Title 10.1 of the Code of Virginia.
2. For findings by the owner's engineer resulting from analyses conducted in accordance with subdivision C 2 of this section:
a. If the engineer finds that the impounding structure has a low hazard potential classification, the owner may be eligible for general permit coverage in accordance with 4VAC50-20-103; or
b. If the engineer finds that the impounding structure appears to have a high or significant hazard potential classification, then the owner shall comply with the applicable certification requirements set out in this chapter.
E. An incremental damage analysis in accordance with 4VAC50-20-52 may be utilized as part of a hazard potential classification by the owner's engineer.
F. Impounding structures shall be subject to reclassification by the board as necessary.

4 Va. Admin. Code § 50-20-40

Derived from VR625-01-00 § 1.4, eff. February 1, 1989; amended, Virginia Register Volume 24, Issue 25, eff. September 26, 2008; Volume 29, Issue 2, eff. November 8, 2012.

Statutory Authority

§ 10.1-605 of the Code of Virginia.