Lower frequency limit of measuring system, in Hz (+3 dB) | Maximum level, in dB |
0.1 Hz or lower - flat response1 | 134 peak |
2 Hz or lower - flat response | 133 peak |
6 Hz or lower - flat response | 129 peak |
C-weighted - slow response1 | 105 peak dBC |
1Only when approved by the division |
Distance (D), from the blasting site, in feet | Maximum allowable peak particle velocity (Vmax) for ground vibration, in seismic inches/second1 | Scaled distance factor to be applied without seismic monitoring2 (D5) |
0 to 300 | 1.25 | 50 |
301 to 5,000 | 1.00 | 55 |
5,001 and beyond | 0.75 | 65 |
1Ground vibration shall be measured as the particle velocity. Particle velocity shall be recorded in three mutually perpendicular directions. The maximum allowable peak particle velocity shall apply to each of the three measurements. | ||
2Applicable to the scaled-distance equation of Paragraph (d)(3)(i) of this section. |
4 Va. Admin. Code § 25-130-817.67
Statutory Authority
§§ 45.1-161.3 and 45.1-230 of the Code of Virginia.