24 Va. Admin. Code § 30-151-380

Current through Register Vol. 40, No. 22, June 17, 2024
Section 24VAC30-151-380 - Appurtenances
A. When vents are required they shall be located at the high end of casings less than 150 feet in length and generally at both ends of casings longer than 150 feet. Vent standpipes shall be on or beyond the right-of-way line to prevent interference with maintenance or pedestrian traffic.
B. A permit may be granted to install drains for any underground facility. The permittee shall ensure the achievement of positive drainage.
C. National uniform color codes for identification of utilities shall be used to place permanent markers.
D. Manholes shall be placed in the shoulders, utility strips, or other suitable locations. When no other alternative is available, consideration will be given to placement of manholes in the pavement surface. Every effort should be made to minimize manhole installations at street intersections and in the normal wheel path of the travel lanes. Manholes shall be designed and located in such a manner that shall cause the least interference to other utilities and future highway expansion.
E. Manhole frames and covers, valve boxes, and other castings located within the paved roadway, shoulder, or sidewalk shall be constructed flush with the finished grade. Manhole frames and covers, valve boxes, and other castings located within sidewalk areas shall be constructed in accordance with the Americans with Disabilities Act ( 42 USC § 12101 et seq.).
F. The permittee shall install shutoff valves, preferably automatic, in lines at or near the ends of structures and near unusual hazards, unless other sectionalizing devices within a reasonable distance can isolate hazardous segments.

24 Va. Admin. Code § 30-151-380

Derived from Virginia Register Volume 26, Issue 12, eff. March 17, 2010.

Statutory Authority

§ 33.1-12 of the Code of Virginia.