13 Va. Admin. Code § 5-63-295

Current through Register Vol. 40, No. 22, June 17, 2024
Section 13VAC5-63-295 - Chapter 23 Wood
A. Add Exception 2 to Item 2 of Section 2308.2.3 of the IBC to read:
2. Concrete slab-on-grade live load limited only by allowable soil bearing pressure.
B. Add Exception 4 to Section 2308.2.3 of the IBC to read:
4. Where design for tornado loads is required, tornado loads on the main wind force resisting system and all components and cladding shall not exceed the corresponding wind loads on these same elements.

13 Va. Admin. Code § 5-63-295

Derived From Virginia Register Volume 30, Issue 16, eff. July 14, 2014; Amended, Virginia Register Volume 34, Issue 18, eff. 9/4/2018; Amended, Virginia Register Volume 37, Issue 14, eff. 7/1/2021; Amended, Virginia Register Volume 40, Issue 9, eff. 1/18/2024.

Statutory Authority: § 36-98 of the Code of Virginia.