TABLE 1 SEPARATION DISTANCES (IN FEET) BETWEEN A WELL AND A STRUCTURE OR TOPOGRAPHIC FEATURE | |||||
Feature | Minimum Separation Distance | Exceptions | |||
Class IIIA/B | Class IIIC | Class IVA/B | Class IVC | ||
1. Building foundation | 15 | 15 | 15 | 15 | 10 feet if structure is treated with borate based termite treatment |
2. House sewer line a. Constructed of cast iron pipe with water-tight caulked joints; mechanical joints using neoprene gaskets; or solvent welded Schedule 40 or better PVC pipe - provided the well is cased and grouted to water bearing formation | 10 | 10 | 10 | 10 | None |
b. Other or unknown construction; or if well is not cased and grouted to water bearing formation | 50 | 50 | 50 | 50 | None |
3. Sewer main, including force main a. Constructed of ductile iron pipe with water-tight joints; solvent welded Schedule 40 or better PVC (SDR-35 plastic PVC with neoprene gaskets) - provided the well is cased and grouted to water bearing formation | 35 | 35 | 35 | 35 | None |
b. Other or unknown construction; or if well is not cased and grouted to water bearing formation | 50 | 50 | 50 | 50 | None |
4. Sewerage system | 50 | 50 | 50 | 50 | None |
5. Active or permitted pretreatment system (e.g., septic tank or aerobic unit) | 50 | 50 | 50 | 50 | None |
6. Active or permitted drainfield (including reserve drainfield). | 50 | 100 | 50 | 100 | None |
7. Other contamination source (e.g., petroleum storage tank, drum, tote or other container aboveground or underground, barnyard, landfill, animal lot, fertilizer or pesticide storage) | 50 | 100 | 50 | 100 | Tanks containing propane or other liquified petroleum gases are not deemed sources of contamination. However, the National Fire Protection Association Liquified Petroleum Gas Code (NFPA-58) recommends a minimum of 10 feet from sources of ignition. |
8. Permanently abandoned sewage disposal systems | 25 | 25 | 25 | 25 | None |
9. Reclaimed water distribution pipeline | 50 | 50 | 50 | 50 | 35 feet if RWDP is constructed of water pipe material in accordance with 9VAC25-740-110. |
10. Biosolids application fields (as field is defined in 9VAC25-32-10) | 100 | 100 | 100 | 100 | No separation distance applies if biosolids have not been applied within the 12 months preceding well construction. |
11. Bioretention pond a. Unlined | 50 | 50 | 50 | 50 | |
b. Lined | 10 | 10 | 10 | 10 | |
12. Cemetery | 50 | 100 | 50 | 100 | None |
13. Sewage dump station | 50 | 100 | 50 | 100 | None |
14. Property line a. All properties except as described in subdivision 14 b of this table | 5 | 5 | 5 | 5 | None |
b. With an adjacent property of three acres or larger used for an agricultural operation as defined in § 3.2-300 of the Code of Virginia. | 50 | 50 | 50 | 50 | Exemption for reduced distance applies if the adjacent property owner grants written permission for construction within 50 feet of the property line, or if it is certified that no other site on the property complies with the regulations for construction of a private well. |
12 Va. Admin. Code § 5-630-380
Statutory Authority: §§ 32.1-12 and 32.1-176 of the Code of Virginia.