12 Va. Admin. Code § 5-610-597
Current through Register Vol. 41, No. 10, December 30, 2024
Table 4.1. Minimum Separation Distances for Pretreatment Units, Conveyance Lines, and Header Lines. | |
Structure or Topographic Features | Minimum Horizontal Distance |
Property Lines | 5 |
Building Foundations | 10 |
Basements | 20 |
Drinking Water Wells (all classes) | 50 |
Cisterns Bottom Elevation Lower than Ground Surface in Area of Pretreatment Unit) | 100 |
Shellfish Waters | 70 |
Natural Lakes & Impounded Waters and Streams | 50 |
Developed Springs (when the spring is down slope) | 100 |
Drainage Ditches: | |
Ditch Bottoms above Seasonal Water Table | 10 |
Ditch Bottom below Seasonal Water Table and Ditch Normally Contains Water | 50 |
Lateral Ground Water Movement Interceptor | 50 |
Low Point of Sink Holes When Placed within the Bowl of the Sink Hole | 100 |
Utility Lines | 10 |
Table 4.2. Minimum Separation Distances. | |||
Structure or Topographic Features | Soil Texture Group | Minimum Distance (Ft) from Bottom or Sidewall of Subsurface Soil Absorption System Trench | |
Vertical | Horizontal | ||
Property Lines | I, II, III, IV | -- | 5 |
Building Foundations | I, II, III, IV | -- | 10 |
Basements | I, II, III, IV | -- | 20 |
Drinking Water Wells | |||
Class IIIA or IIIB | I, II, III, IV | -- | 50 |
Class IIIC or IV | I, II, III, IV | -- | 100 |
Cisterns (Bottom Elevation Lower than Ground Surface in Area of Subsurface Soil Absorption System) | I, II, III, IV | -- | 100 |
Shellfish Waters | I, II, III, IV | -- | 70 |
Natural Lakes & Impounded Waters | I, II, III, IV | -- | 50 |
Streams | I, II, III, IV | -- | 50a |
Developed Springs (when the spring is down slope) | I, II, III, IV | -- | 200e |
Rock and Rock Outcropping | I | 2 | 2 |
Rock and Rock Outcropping | II, III, IV | 1.5 | 1.5 |
Pans and Impervious Strata | I, II, III, IV | 1.5 | 1.5 |
Drainage Ditches: | |||
Ditch Bottoms above Seasonal Water Table | I, II, III, IV | -- | 10 |
Ditch Bottom below Seasonal Water Table and Ditch Normally Contains Water | I | -- | 70a |
II | -- | 70a | |
III | -- | 50a | |
IV | -- | 50a | |
Water Table Depressor System | I | 6b | 70 |
II | 3b | 70 | |
III | 2b | 50 | |
IV | 2 | 50 | |
Lateral Ground Water | I | -- | 70c 10d |
Movement Interceptor | II | -- | 70c 10d |
III | -- | 50c 10d | |
IV | -- | 50c 10d | |
Low Point of Sink Holes When Placed within the Bowl of the Sink Hole | I, II, III, IV | -- | 100 |
Utility Lines | I, II, III, IV | -- | 10 |
aThe set back distance may be reduced to 10 feet in Group III and IV soils and 20 feet in Group I and II soils if the subsurface soil absorption system is designed to produce unsaturated flow condition in the soil. | |||
bVertical Distance to the invert of the drain tile in the water table depressor system. | |||
cAbsorption trench up slope from interceptor. | |||
dAbsorption trench down slope from interceptor. | |||
eArc of 180 degree up slope of spring and 100 ft. down slope. |
Table 4.3. Summary of Separation Distances between Systems Using Naturally Occurring Undisturbed Soils and Limiting Site Factors. | ||||
Site Factor | In-Ground System1 | Shallow-Placed System1 | ||
Septic Tank Effluent | Secondary Effluent | Septic Tank Effluent | Secondary Effluent | |
Bed Rock | 18" | 12" | n/a | 18" |
Restriction | 18" | 12" | n/a | 18" |
Shrink-Swell Soil | 18" | 12" | n/a | 18" |
Slope | 50% | 50% | n/a | 50% |
Perc Rate | 5-120 mpi | 5-120 mpi | n/a | 5-45 mpi |
Water Table | 18" | 12" | n/a | 12" |
1The separation distances for in-ground and shallow-placed systems are measured from the trench bottom or other infiltrative interface vertically down to listed site factor. |
Table 4.4. Summary of Separation Distances between Fill Systems and Limiting Site Factors. | ||||||
Elevated Sand Mound | Sand-on-Sand System2 | Noncarbonaceous Mountain Colluvium | ||||
Site Factor | Septic Tank Effluent | Secondary Effluent | Septic Tank Effluent | Secondary Effluent | Septic Tank Effluent | Secondary Effluent |
Bed Rock | 24"1 | 24"1 | 60" | 60" | 18" | 12" |
Restriction | 24" | 12" | 30" | 24" | 18" | 12" |
Shrink-Swell Soil | 24" | 12" | 40" | 30" | 18" | 12" |
Slope 25% | 25% | 25% | 5% | 5% | 50% | 50% |
Perc Rate | 5-120 mpi | 5-120 mpi | 5-30 mpi | 5-30 mpi | 5-120 mpi | 5-120 mpi |
Water Table | 24" | 10" | 18" | 12" | 18" | 12" |
124 inches refers to creviced bedrock. This distance may be reduced to 12 inches when noncreviced bedrock is encountered. See the Wisconsin Mound Soil Absorption System Siting, Design, and Construction Manual, January 1990. | ||||||
2The separation distance for sand-on-sand systems is measured from the ground surface vertically down to the listed site factor. |
12 Va. Admin. Code § 5-610-597
Statutory Authority
§§ 32.1-12 and 32.1-164 of the Code of Virginia.