Section 12VAC5-590-720 - Building design and constructionA. In accordance with the USBC, Chapter 6 (§ 36.97 et seq.) of Title 36 of the Code of Virginia, and the Statewide Fire Prevention Code (§ 27.94 et seq.) of Title 27 of the Code of Virginia, all waterworks building design and construction shall include necessary features that will assure a functional and safe environment, including adequate ventilation, lighting, heating, drainage, dehumidification, and accessibility to equipment for operation and maintenance.B. Consistent with subdivision A of this section, the waterworks building design and layout shall incorporate safety provisions to protect waterworks operators and other personnel, in accordance with Article 1 (§ 40.1-22 ) of Chapter 3 of Title 40.1 of the Code of Virginia. These provisions must comply with federal occupational safety and health standards and regulations promulgated under 29 USC § 651 et seq. and shall include separation of incompatible chemicals, confined space entry, handrails and guards, ladders, lighting, warning signs, smoke detectors, chlorine leak detectors, protective equipment, safety showers, eye washes, and fire extinguishers.C. Positive identification of the contents of a piping system shall be by lettered legend giving the name of the contents. Arrows shall be used to indicate the direction of flow. Legends shall be applied close to valves, adjacent to changes in direction and branches, where pipes pass through walls and floors, and at frequent intervals on straight pipe runs. The lettering shall be of such color, size, and location so as to be clearly visible and readable.D. Common division walls between basins or conduits containing nonpotable water and potable water are prohibited. Vertical double division walls, where separated sufficiently to permit ready access for inspection, are permissible where the division walls are monolithic in construction and are properly keyed into their footings or are cast monolithically with their footings.E. Shop space and storage facilities shall be provided.F. Wherever pipes pass through walls of concrete structures, extra wall castings to facilitate expansion and future uses shall be provided.12 Va. Admin. Code § 5-590-720
Derived from VR355-18-007.09 § 3.9, eff. August 1, 1991; amended, Virginia Register Volume 9, Issue 17, eff. June 23, 1993; Amended, Virginia Register Volume 37, Issue 20, eff. 6/23/2021.Statutory Authority: §§ 32.1-12 and 32.1-170 of the Code of Virginia.