12 Va. Admin. Code § 5-421-2190

Current through Register Vol. 41, No. 6, November 4, 2024
Section 12VAC5-421-2190 - Handwashing sink, water temperature, and flow
A. A handwashing sink shall be equipped to provide water at a temperature of at least 100°F (38°C) through a mixing valve or combination faucet.Pf
B. A steam mixing valve shall not be used at a handwashing sink.
C. A self-closing, slow-closing, or metering faucet shall provide a flow of water for at least 15 seconds without the need to reactivate the faucet.
D. An automatic handwashing facility shall be installed in accordance with manufacturer's instructions.

12 Va. Admin. Code § 5-421-2190

Derived from Virginia Register Volume 18, Issue 10, eff. March 1, 2002; amended, Virginia Register Volume 24, Issue 2, eff. October 16, 2007; Volume 26, Issue 7, eff. January 1, 2010; Amended, Virginia Register Volume 32, Issue 22, eff. 7/12/2016.