Utah Admin. Code 650-217-1

Current through Bulletin 2024-12, June 15, 2024
Section R650-217-1 - Fire Extinguishers Required
(1) A motorboat operator shall ensure the motorboat has on board a fire extinguisher in the quantity and sizes set out in the below Table 1.

TABLE 1

LENGTH OF MOTORBOAT

NUMBER/SIZE

Less than 26 feet in length

1/B-I

26 feet to less than 40 feet in length

2/B-I or 1/B-II

40 feet to 65 feet in length

3/B-I or 1/B-I and 1/B-II

(2) A motorboat operator is not required to have a fire extinguisher on board the vessel if the vessel is:
(a) less than 26 feet in length;
(b) of open construction; and
(c) not carrying passengers for hire.
(3) If a motorboat is not equipped with an engine compartment, a motorboat operator is not required to have a fixed extinguishing system on board the vessel.
(4) If a motorboat operator is required to have a B-II size fire extinguisher on board a vessel, the operator shall place the B-II size fire extinguisher near the stern.
(5) If a motorboat is not equipped with a galley and the motorboat operator is required to carry a B-II size fire extinguisher on board the vessel, the operator shall place the B-II size fire extinguisher midship.
(6) A vessel operator shall ensure each fire extinguisher carried on board a vessel pursuant to this rule is properly charged.

Utah Admin. Code R650-217-1

Adopted by Utah State Bulletin Number 2024-02, effective 1/9/2024