Where:
Eh = Total organic mass flow rate, kg/h.
Q2sd = Volumetric flow rate of gases entering or exiting control device, as determined by Method 2, dscm/h.
n = Number of organic compounds in the vent gas.
Ci = Organic concentration in ppm, dry basis, of compound i in the vent gas, as determined by Method 18.
MWi = Molecular weight of organic compound i in the vent gas, kg/kg-mol.
0.0416 = Conversion factor for molar volume, kg-mol/m3 (@ 293 K and 760 mm Hg).
10-6 = Conversion from ppm.
Eh = (Q)(C)(MW)(0.0416)(10-6).
Where:
Eh = Total organic mass flow rate, kg/h.
Q = Volumetric flow rate of gases entering or exiting control device, as determined by Method 2, dscm/h.
C = Organic concentration in ppm, dry basis, as determined by Method 25A.
MW = Molecular weight of propane, 44.
0.0416 = Conversion factor for molar volume, kg-mol/m3 (@ 293 K and 760 mm Hg).
10-6 = Conversion from ppm.
EA = (Eh) (H).
where:
EA = Total organic mass emission rate, kg/y.
Eh = Total organic mass flow rate for the process vent, kg/h.
H = Total annual hours of operations for the affected unit, h.
Utah Admin. Code R315-265-1034