Current through Bulletin No. 2024-21, November 1, 2024
Section R307-508-3 - VOC Control Device Requirements(1) A VOC control device required by Rule R307-506 or R307-507 must have a control efficiency of 95% or greater(a) The VOC control device shall operate with no visible emissions.(b) The VOC control device must comply with Rule R307-503.(2) A well site shall demonstrate compliance by meeting the performance test methods and procedures specified in 40 CFR 60.5413a.(3) VOC control devices and all associated equipment shall be inspected monthly by audio, visual, or olfactory (AVO) means to ensure the integrity of the equipment is maintained and is operational. If equipment is not operational, corrective action shall be taken within 15 days of discovery.Utah Admin. Code R307-508-3
Adopted by Utah State Bulletin Number 2018-7, effective 3/5/2018Amended by Utah State Bulletin Number 2022-18, effective 9/6/2022