No owner or operator shall apply coatings with a VOC content greater than the amounts specified in Table 1, unless the owner or operator uses an add-on control device as specified in R307-347-7.
TABLE 1
Large Appliance Surface Coating Limitations (values in pounds VOC per gallon of coating, minus water and exempt solvents(compounds not classified as VOC as defined in R307-101-2), as applied)
Coating Category | Baked | VOC Content Limits (lb/gal) Air Dried |
General, one component | 2.3 | 2.3 |
General, multi-component | 2.3 | 2.8 |
Extreme high gloss | 3.0 | 2.8 |
Extreme performance | 3.0 | 3.5 |
Heat resistance | 3.0 | 3.5 |
Solar absorbent | 3.0 | 3.5 |
Metallic | 3.5 | 3.5 |
Pretreatment coatings | 3.5 | 3.5 |
Utah Admin. Code R307-347-5