Current through Reg. 49, No. 44; November 1, 2024
Section 261.334 - Violent CellsA facility may contain one or more single occupancy cells for the temporary holding of violent persons. Violent cells shall include the following features and equipment.
(1) Furnishings. The cell shall be equipped with a hammock, not less than two feet-three inches wide and six feet-three inches long, made of an elastic or fibrous fabric. A bench abutting the wall, the length or width of the cell, at least two feet-three inches wide and six feet-three inches long and not more than eight inches above the floor may be provided in lieu of a hammock.(2) Plumbing. Flushing type floor drains with outside controls shall be provided.(3) Cell Size. Cell shall contain not less than 40 square feet of floor space.(4) Padding. Walls, floor, and bench shall be completely covered with a material to protect the inmate from self injury. The type of material used to cover the walls, floor, and bench shall be fire resistive and nontoxic.37 Tex. Admin. Code § 261.334
The provisions of this §261.334 adopted to be effective December 19, 1994, 19 TexReg 9526.