Current through Reg. 49, No. 50; December 13, 2024
Section 291.133 - Pharmacies Compounding Sterile Preparations(a) Purpose. Pharmacies compounding sterile preparations, prepackaging pharmaceutical products, and distributing those products shall comply with all requirements for their specific license classification and this section. The purpose of this section is to provide standards for the: (1) compounding of sterile preparations pursuant to a prescription or medication order for a patient from a practitioner in Class A-S, Class B, Class C-S, and Class E-S pharmacies;(2) compounding, dispensing, and delivery of a reasonable quantity of a compounded sterile preparation in Class A-S, Class B, Class C-S, and Class E-S pharmacies to a practitioner's office for office use by the practitioner;(3) compounding and distribution of compounded sterile preparations by a Class A-S pharmacy for a Class C-S pharmacy; and(4) compounding of sterile preparations by a Class C-S pharmacy and the distribution of the compounded preparations to other Class C or Class C-S pharmacies under common ownership.(b) Definitions. In addition to the definitions for specific license classifications, the following words and terms, when used in this section, shall have the following meanings, unless the context clearly indicates otherwise. (1) ACPE--Accreditation Council for Pharmacy Education.(2) Airborne particulate cleanliness class--The level of cleanliness specified by the maximum allowable number of particles per cubic meter of air as specified in the International Organization of Standardization (ISO) Classification Air Cleanliness (ISO 14644-1). For example:(A) ISO Class 5 (formerly Class 100) is an atmospheric environment that contains less than 3,520 particles 0.5 microns in diameter per cubic meter of air (formerly stated as 100 particles 0.5 microns in diameter per cubic foot of air);(B) ISO Class 7 (formerly Class 10,000) is an atmospheric environment that contains less than 352,000 particles 0.5 microns in diameter per cubic meter of air (formerly stated as 10,000 particles 0.5 microns in diameter per cubic foot of air); and(C) ISO Class 8 (formerly Class 100,000) is an atmospheric environment that contains less than 3,520,000 particles 0.5 microns in diameter per cubic meter of air (formerly stated as 100,000 particles 0.5 microns in diameter per cubic foot of air).(3) Ancillary supplies--Supplies necessary for the preparation and administration of compounded sterile preparations.(4) Ante-area--An ISO Class 8 or better area where personnel may perform hand hygiene and garbing procedures, staging of components, order entry, labeling, and other high-particulate generating activities. It is also a transition area that: (A) provides assurance that pressure relationships are constantly maintained so that air flows from clean to dirty areas; and(B) reduces the need for the heating, ventilating and air conditioning (HVAC) control system to respond to large disturbances.(5) Aseptic Processing--A mode of processing pharmaceutical and medical preparations that involves the separate sterilization of the preparation and of the package (containers-closures or packaging material for medical devices) and the transfer of the preparation into the container and its closure under at least ISO Class 5 conditions.(6) Automated compounding device--An automated device that compounds, measures, and/or packages a specified quantity of individual components in a predetermined sequence for a designated sterile preparation.(7) Batch--A specific quantity of a drug or other material that is intended to have uniform character and quality, within specified limits, and is produced during a single preparation cycle.(8) Batch preparation compounding--Compounding of multiple sterile preparation units, in a single discrete process, by the same individual(s), carried out during one limited time period. Batch preparation/compounding does not include the preparation of multiple sterile preparation units pursuant to patient specific medication orders.(9) Beyond-use date--The date or time after which the compounded sterile preparation shall not be stored or transported or begin to be administered to a patient. The beyond-use date is determined from the date or time the preparation is compounded.(10) Biological Safety Cabinet, Class II--A ventilated cabinet for personnel, product or preparation, and environmental protection having an open front with inward airflow for personnel protection, downward HEPA filtered laminar airflow for product protection, and HEPA filtered exhausted air for environmental protection.(11) Buffer Area--An ISO Class 7 or, if a Class B pharmacy, ISO Class 8 or better, area where the primary engineering control area is physically located. Activities that occur in this area include the preparation and staging of components and supplies used when compounding sterile preparations.(12) Clean room--A room in which the concentration of airborne particles is controlled to meet a specified airborne particulate cleanliness class. Microorganisms in the environment are monitored so that a microbial level for air, surface, and personnel gear are not exceeded for a specified cleanliness class.(13) Component--Any ingredient intended for use in the compounding of a drug preparation, including those that may not appear in such preparation.(14) Compounding--The preparation, mixing, assembling, packaging, or labeling of a drug or device: (A) as the result of a practitioner's prescription drug or medication order based on the practitioner-patient-pharmacist relationship in the course of professional practice;(B) for administration to a patient by a practitioner as the result of a practitioner's initiative based on the practitioner-patient-pharmacist relationship in the course of professional practice;(C) in anticipation of prescription drug or medication orders based on routine, regularly observed prescribing patterns; or(D) for or as an incident to research, teaching, or chemical analysis and not for sale or dispensing, except as allowed under §562.154 or Chapter 563 of the Occupations Code.(15) Compounding Aseptic Isolator--A form of barrier isolator specifically designed for compounding pharmaceutical ingredients or preparations. It is designed to maintain an aseptic compounding environment within the isolator throughout the compounding and material transfer processes. Air exchange into the isolator from the surrounding environment shall not occur unless it has first passed through a microbial retentive filter (HEPA minimum).(16) Compounding Aseptic Containment Isolator--A compounding aseptic isolator designed to provide worker protection from exposure to undesirable levels of airborne drug throughout the compounding and material transfer processes and to provide an aseptic environment for compounding sterile preparations. Air exchange with the surrounding environment should not occur unless the air is first passed through a microbial retentive filter (HEPA minimum) system capable of containing airborne concentrations of the physical size and state of the drug being compounded. Where volatile hazardous drugs are prepared, the exhaust air from the isolator should be appropriately removed by properly designed building ventilation.(17) Compounding Personnel--A pharmacist, pharmacy technician, or pharmacy technician trainee who performs the actual compounding; a pharmacist who supervises pharmacy technicians or pharmacy technician trainees compounding sterile preparations, and a pharmacist who performs an intermediate or final verification of a compounded sterile preparation.(18) Critical Area--An ISO Class 5 environment.(19) Critical Sites--A location that includes any component or fluid pathway surfaces (e.g., vial septa, injection ports, beakers) or openings (e.g., opened ampules, needle hubs) exposed and at risk of direct contact with air (e.g., ambient room or HEPA filtered), moisture (e.g., oral and mucosal secretions), or touch contamination. Risk of microbial particulate contamination of the critical site increases with the size of the openings and exposure time.(20) Device--An instrument, apparatus, implement, machine, contrivance, implant, in-vitro reagent, or other similar or related article, including any component part or accessory, that is required under federal or state law to be ordered or prescribed by a practitioner.(21) Direct Compounding Area--A critical area within the ISO Class 5 primary engineering control where critical sites are exposed to unidirectional HEPA-filtered air, also known as first air.(22) Disinfectant--An agent that frees from infection, usually a chemical agent but sometimes a physical one, and that destroys disease-causing pathogens or other harmful microorganisms but may not kill bacterial and fungal spores. It refers to substances applied to inanimate objects.(23) First Air--The air exiting the HEPA filter in a unidirectional air stream that is essentially particle free.(24) Hazardous Drugs--Drugs that, studies in animals or humans indicate exposure to the drugs, have a potential for causing cancer, development or reproductive toxicity, or harm to organs. For the purposes of this chapter, radiopharmaceuticals are not considered hazardous drugs.(25) Hot water--The temperature of water from the pharmacy's sink maintained at a minimum of 105 degrees F (41 degrees C).(26) HVAC--Heating, ventilation, and air conditioning.(27) Immediate use--A sterile preparation that is not prepared according to USP 797 standards (i.e., outside the pharmacy and most likely not by pharmacy personnel) which shall be stored for no longer than one hour after completion of the preparation.(28) IPA--Isopropyl alcohol (2-propanol).(29) Labeling--All labels and other written, printed, or graphic matter on an immediate container of an article or preparation or on, or in, any package or wrapper in which it is enclosed, except any outer shipping container. The term "label" designates that part of the labeling on the immediate container.(30) Media-Fill Test--A test used to qualify aseptic technique of compounding personnel or processes and to ensure that the processes used are able to produce sterile preparation without microbial contamination. During this test, a microbiological growth medium such as Soybean-Casein Digest Medium is substituted for the actual drug preparation to simulate admixture compounding. The issues to consider in the development of a media-fill test are the following: media-fill procedures, media selection, fill volume, incubation, time and temperature, inspection of filled units, documentation, interpretation of results, and possible corrective actions required.(31) Multiple-Dose Container--A multiple-unit container for articles or preparations intended for potential administration only and usually contains antimicrobial preservatives. The beyond-use date for an opened or entered (e.g., needle-punctured) multiple-dose container with antimicrobial preservatives is 28 days, unless otherwise specified by the manufacturer.(32) Negative Pressure Room--A room that is at a lower pressure compared to adjacent spaces and, therefore, the net flow of air is into the room.(33) Office use--The administration of a compounded drug to a patient by a practitioner in the practitioner's office or by the practitioner in a health care facility or treatment setting, including a hospital, ambulatory surgical center, or pharmacy in accordance with Chapter 562 of the Act, or for administration or provision by a veterinarian in accordance with §563.054 of the Act.(34) Pharmacy Bulk Package--A container of a sterile preparation for potential use that contains many single doses. The contents are intended for use in a pharmacy admixture program and are restricted to the preparation of admixtures for infusion or, through a sterile transfer device, for the filling of empty sterile syringes. The closure shall be penetrated only one time after constitution with a suitable sterile transfer device or dispensing set, which allows measured dispensing of the contents. The pharmacy bulk package is to be used only in a suitable work area such as a laminar flow hood (or an equivalent clean air compounding area).(35) Prepackaging--The act of repackaging and relabeling quantities of drug products from a manufacturer's original container into unit dose packaging or a multiple dose container for distribution within a facility licensed as a Class C pharmacy or to other pharmacies under common ownership for distribution within those facilities. The term as defined does not prohibit the prepackaging of drug products for use within other pharmacy classes.(36) Preparation or Compounded Sterile Preparation--A sterile admixture compounded in a licensed pharmacy or other healthcare-related facility pursuant to the order of a licensed prescriber. The components of the preparation may or may not be sterile products.(37) Primary Engineering Control--A device or room that provides an ISO Class 5 environment for the exposure of critical sites when compounding sterile preparations. Such devices include, but may not be limited to, laminar airflow workbenches, biological safety cabinets, compounding aseptic isolators, and compounding aseptic containment isolators.(38) Product--A commercially manufactured sterile drug or nutrient that has been evaluated for safety and efficacy by the U.S. Food and Drug Administration (FDA). Products are accompanied by full prescribing information, which is commonly known as the FDA-approved manufacturer's labeling or product package insert.(39) Positive Control--A quality assurance sample prepared to test positive for microbial growth.(40) Quality assurance--The set of activities used to ensure that the process used in the preparation of sterile drug preparations lead to preparations that meet predetermined standards of quality.(41) Quality control--The set of testing activities used to determine that the ingredients, components (e.g., containers), and final compounded sterile preparations prepared meet predetermined requirements with respect to identity, purity, non-pyrogenicity, and sterility.(42) Reasonable quantity--An amount of a compounded drug that: (A) does not exceed the amount a practitioner anticipates may be used in the practitioner's office or facility before the beyond use date of the drug;(B) is reasonable considering the intended use of the compounded drug and the nature of the practitioner's practice; and(C) for any practitioner and all practitioners as a whole, is not greater than an amount the pharmacy is capable of compounding in compliance with pharmaceutical standards for identity, strength, quality, and purity of the compounded drug that are consistent with United States Pharmacopoeia guidelines and accreditation practices.(43) Segregated Compounding Area--A designated space, either a demarcated area or room, that is restricted to preparing low-risk level compounded sterile preparations with 12-hour or less beyond-use date. Such area shall contain a device that provides unidirectional airflow of ISO Class 5 air quality for preparation of compounded sterile preparations and shall be void of activities and materials that are extraneous to sterile compounding.(44) Single-dose container--A single-unit container for articles or preparations intended for parenteral administration only. It is intended for a single use. A single-dose container is labeled as such. Examples of single-dose containers include pre-filled syringes, cartridges, fusion-sealed containers, and closure-sealed containers when so labeled.(45) SOPs--Standard operating procedures.(46) Sterilizing Grade Membranes--Membranes that are documented to retain 100% of a culture of 107 microorganisms of a strain of Brevundimonas (Pseudomonas) diminuta per square centimeter of membrane surface under a pressure of not less than 30 psi (2.0 bar). Such filter membranes are nominally at 0.22-micrometer or 0.2-micrometer nominal pore size, depending on the manufacturer's practice.(47) Sterilization by Filtration--Passage of a fluid or solution through a sterilizing grade membrane to produce a sterile effluent.(48) Terminal Sterilization--The application of a lethal process, e.g., steam under pressure or autoclaving, to sealed final preparation containers for the purpose of achieving a predetermined sterility assurance level of usually less than 10-6 or a probability of less than one in one million of a non-sterile unit.(49) Unidirectional Flow--An airflow moving in a single direction in a robust and uniform manner and at sufficient speed to reproducibly sweep particles away from the critical processing or testing area.(50) USP/NF--The current edition of the United States Pharmacopeia/National Formulary.(c) Personnel. (1) Pharmacist-in-charge. (A) General. The pharmacy shall have a pharmacist-in-charge in compliance with the specific license classification of the pharmacy.(B) Responsibilities. In addition to the responsibilities for the specific class of pharmacy, the pharmacist-in-charge shall have the responsibility for, at a minimum, the following concerning the compounding of sterile preparations: (i) developing a system to ensure that all pharmacy personnel responsible for compounding and/or supervising the compounding of sterile preparations within the pharmacy receive appropriate education and training and competency evaluation;(ii) determining that all personnel involved in compounding sterile preparations obtain continuing education appropriate for the type of compounding done by the personnel;(iii) supervising a system to ensure appropriate procurement of drugs and devices and storage of all pharmaceutical materials including pharmaceuticals, components used in the compounding of sterile preparations, and drug delivery devices;(iv) ensuring that the equipment used in compounding is properly maintained;(v) developing a system for the disposal and distribution of drugs from the pharmacy;(vi) developing a system for bulk compounding or batch preparation of drugs;(vii) developing a system for the compounding, sterility assurance, quality assurance, and quality control of sterile preparations; and(viii) if applicable, ensuring that the pharmacy has a system to dispose of hazardous waste in a manner so as not to endanger the public health.(2) Pharmacists. (A) General. (i) A pharmacist is responsible for ensuring that compounded sterile preparations are accurately identified, measured, diluted, and mixed and are correctly purified, sterilized, packaged, sealed, labeled, stored, dispensed, and distributed.(ii) A pharmacist shall inspect and approve all components, drug preparation containers, closures, labeling, and any other materials involved in the compounding process.(iii) A pharmacist shall review all compounding records for accuracy and conduct periodic in-process checks as defined in the pharmacy's policy and procedures.(iv) A pharmacist shall review all compounding records for accuracy and conduct a final check.(v) A pharmacist is responsible for ensuring the proper maintenance, cleanliness, and use of all equipment used in the compounding process.(vi) A pharmacist shall be accessible at all times, 24 hours a day, to respond to patients' and other health professionals' questions and needs.(B) Initial training and continuing education.(i) All pharmacists who compound sterile preparations or supervise pharmacy technicians and pharmacy technician trainees compounding sterile preparations shall comply with the following: (I) complete through a single course, a minimum of 20 hours of instruction and experience in the areas listed in paragraph (4)(D) of this subsection. Such training shall be obtained through completion of a recognized course in an accredited college of pharmacy or a course sponsored by an ACPE accredited provider;(II) complete a structured on-the-job didactic and experiential training program at this pharmacy which provides sufficient hours of instruction and experience in the facility's sterile compounding processes and procedures. Such training may not be transferred to another pharmacy unless the pharmacies are under common ownership and control and use a common training program; and(III) possess knowledge about: (-a-) aseptic processing;(-b-) quality control and quality assurance as related to environmental, component, and finished preparation release checks and tests;(-c-) chemical, pharmaceutical, and clinical properties of drugs;(-d-) container, equipment, and closure system selection; and(-e-) sterilization techniques.(ii) The required experiential portion of the training programs specified in this subparagraph must be supervised by an individual who is actively engaged in performing sterile compounding and is qualified and has completed training as specified in this paragraph or paragraph (3) of this subsection.(iii) In order to renew a license to practice pharmacy, during the previous licensure period, a pharmacist engaged in sterile compounding shall complete a minimum of:(I) two hours of ACPE-accredited continuing education relating to one or more of the areas listed in paragraph (4)(D) of this subsection if the pharmacist is engaged in compounding low and medium risk sterile preparations; or(II) four hours of ACPE-accredited continuing education relating to one or more of the areas listed in paragraph (4)(D) of this subsection if the pharmacist is engaged in compounding high risk sterile preparations.(3) Pharmacy technicians and pharmacy technician trainees.(A) General. All pharmacy technicians and pharmacy technician trainees shall meet the training requirements specified in § 297.6 of this title (relating to Pharmacy Technician and Pharmacy Technician Trainee Training).(B) Initial training and continuing education.(i) Pharmacy technicians and pharmacy technician trainees may compound sterile preparations provided the pharmacy technicians and/or pharmacy technician trainees are supervised by a pharmacist as specified in paragraph (2) of this subsection.(ii) All pharmacy technicians and pharmacy technician trainees who compound sterile preparations for administration to patients shall: (I) have initial training obtained either through completion of:(-a-) a single course, a minimum of 40 hours of instruction and experience in the areas listed in paragraph (4)(D) of this subsection. Such training shall be obtained through completion of a course sponsored by an ACPE accredited provider which provides 40 hours of instruction and experience; or(-b-) a training program which is accredited by the American Society of Health-System Pharmacists.(II) and (-a-) complete a structured on-the-job didactic and experiential training program at this pharmacy which provides sufficient hours of instruction and experience in the facility's sterile compounding processes and procedures. Such training may not be transferred to another pharmacy unless the pharmacies are under common ownership and control and use a common training program; and(-b-) possess knowledge about: (-1-) aseptic processing;(-2-) quality control and quality assurance as related to environmental, component, and finished preparation release checks and tests;(-3-) chemical, pharmaceutical, and clinical properties of drugs;(-4-) container, equipment, and closure system selection; and(-5-) sterilization techniques.(iii) Individuals enrolled in training programs accredited by the American Society of Health-System Pharmacists may compound sterile preparations in a licensed pharmacy provided the: (I) compounding occurs only during times the individual is assigned to a pharmacy as a part of the experiential component of the American Society of Health-System Pharmacists training program;(II) individual is under the direct supervision of and responsible to a pharmacist who has completed training as specified in paragraph (2) of this subsection;(III) supervising pharmacist conducts periodic in-process checks as defined in the pharmacy's policy and procedures; and(IV) supervising pharmacist conducts a final check.(iv) The required experiential portion of the training programs specified in this subparagraph must be supervised by an individual who is actively engaged in performing sterile compounding, is qualified and has completed training as specified in paragraph (2) of this subsection or this paragraph.(v) In order to renew a registration as a pharmacy technician, during the previous registration period, a pharmacy technician engaged in sterile compounding shall complete a minimum of: (I) two hours of ACPE accredited continuing education relating to one or more of the areas listed in paragraph (4)(D) of this subsection if the pharmacy technician is engaged in compounding low and medium risk sterile preparations; or(II) four hours of ACPE accredited continuing education relating to one or more of the areas listed in paragraph (4)(D) of this subsection if the pharmacy technician is engaged in compounding high risk sterile preparations.(4) Evaluation and testing requirements. (A) All pharmacy personnel preparing sterile preparations shall be trained conscientiously and skillfully by expert personnel through multimedia instructional sources and professional publications in the theoretical principles and practical skills of aseptic manipulations, garbing procedures, aseptic work practices, achieving and maintaining ISO Class 5 environmental conditions, and cleaning and disinfection procedures before beginning to prepare compounded sterile preparations.(B) All pharmacy personnel preparing sterile preparations shall perform didactic review and pass written and media-fill testing of aseptic manipulative skills initially followed by: (i) every 12 months for low- and medium-risk level compounding; and(ii) every six months for high-risk level compounding.(C) Pharmacy personnel who fail written tests or whose media-fill tests result in gross microbial colonization shall: (i) be immediately re-instructed and re-evaluated by expert compounding personnel to ensure correction of all aseptic practice deficiencies; and(ii) not be allowed to compound sterile preparations for patient use until passing results are achieved.(D) The didactic and experiential training shall include instruction, experience, and demonstrated proficiency in the following areas: (ii) critical area contamination factors;(iii) environmental monitoring;(iv) structure and engineering controls related to facilities;(v) equipment and supplies;(vi) sterile preparation calculations and terminology;(vii) sterile preparation compounding documentation;(viii) quality assurance procedures;(ix) aseptic preparation procedures including proper gowning and gloving technique;(x) handling of hazardous drugs, if applicable;(xi) cleaning procedures; and(xii) general conduct in the clean room.(E) The aseptic technique of each person compounding or responsible for the direct supervision of personnel compounding sterile preparations shall be observed and evaluated by expert personnel as satisfactory through written and practical tests, and challenge testing, and such evaluation documented. Compounding personnel shall not evaluate their own aseptic technique or results of their own media-fill challenge testing.(F) Media-fill tests must be conducted at each pharmacy where an individual compounds low or medium risk sterile preparations. If pharmacies are under common ownership and control, the media-fill testing may be conducted at only one of the pharmacies provided each of the pharmacies are operated under equivalent policies and procedures and the testing is conducted under the most challenging or stressful conditions. In addition, each pharmacy must maintain documentation of the media-fill test. No preparation intended for patient use shall be compounded by an individual until the on-site media-fill tests indicate that the individual can competently perform aseptic procedures, except that a pharmacist may temporarily compound sterile preparations and supervise pharmacy technicians compounding sterile preparations without media-fill tests provided the pharmacist completes the on-site media-fill tests within seven days of commencing work at the pharmacy.(G) Media-fill tests must be conducted at each pharmacy where an individual compounds high risk sterile preparations. No preparation intended for patient use shall be compounded by an individual until the on-site media-fill tests indicate that the individual can competently perform aseptic procedures, except that a pharmacist may temporarily compound sterile preparations and supervise pharmacy technicians compounding sterile preparations without media-fill tests provided the pharmacist completes the on-site media-fill tests within seven days of commencing work at the pharmacy.(H) Media-fill testing procedures for assessing the preparation of specific types of sterile preparations shall be representative of the most challenging or stressful conditions encountered by the pharmacy personnel being evaluated and, if applicable, for sterilizing high-risk level compounded sterile preparations.(I) Media-fill challenge tests simulating high-risk level compounding shall be used to verify the capability of the compounding environment and process to produce a sterile preparation.(J) Commercially available sterile fluid culture media for low and medium risk level compounding or non-sterile fluid culture media for high risk level compounding shall be able to promote exponential colonization of bacteria that are most likely to be transmitted to compounding sterile preparations from the compounding personnel and environment. Media-filled vials are generally incubated at 20 to 25 degrees Celsius or at 30 to 35 degrees Celsius for a minimum of 14 days. If two temperatures are used for incubation of media-filled samples, then these filled containers should be incubated for at least 7 days at each temperature. Failure is indicated by visible turbidity in the medium on or before 14 days.(K) The pharmacist-in-charge shall ensure continuing competency of pharmacy personnel through in-service education, training, and media-fill tests to supplement initial training. Personnel competency shall be evaluated: (i) during orientation and training prior to the regular performance of those tasks;(ii) whenever the quality assurance program yields an unacceptable result;(iii) whenever unacceptable techniques are observed; and(iv) at least on an annual basis for low- and medium-risk level compounding, and every six months for high-risk level compounding.(L) The pharmacist-in-charge shall ensure that proper hand hygiene and garbing practices of compounding personnel are evaluated prior to compounding, supervising, or verifying sterile preparations intended for patient use and whenever an aseptic media fill is performed. (i) Sampling of compounding personnel glove fingertips shall be performed for all risk level compounding. If pharmacies are under common ownership and control, the gloved fingertip sampling may be conducted at only one of the pharmacies provided each of the pharmacies are operated under equivalent policies and procedures and the testing is conducted under the most challenging or stressful conditions. In addition, each pharmacy must maintain documentation of the gloved fingertip sampling of all compounding personnel.(ii) All compounding personnel shall demonstrate competency in proper hand hygiene and garbing procedures and in aseptic work practices (e.g., disinfection of component surfaces, routine disinfection of gloved hands).(iii) Sterile contact agar plates shall be used to sample the gloved fingertips of compounding personnel after garbing in order to assess garbing competency and after completing the media-fill preparation (without applying sterile 70% IPA).(iv) The visual observation shall be documented and maintained to provide a permanent record and long-term assessment of personnel competency.(v) All compounding personnel shall successfully complete an initial competency evaluation and gloved fingertip/thumb sampling procedure no less than three times before initially being allowed to compound sterile preparations for patient use. Immediately after the compounding personnel completes the hand hygiene and garbing procedure (i.e., after donning of sterile gloves and before any disinfecting with sterile 70% IPA), the evaluator will collect a gloved fingertip and thumb sample from both hands of the compounding personnel onto contact plates or swabs by having the individual lightly touching each fingertip onto the testing medium. The contact plates or swabs will be incubated for the appropriate incubation period and at the appropriate temperature. Results of the initial gloved fingertip evaluations shall indicate zero colony-forming units (0 CFU) growth on the contact plates or swabs, or the test shall be considered a failure. In the event of a failed gloved fingertip test, the evaluation shall be repeated until the individual can successfully don sterile gloves and pass the gloved fingertip evaluation, defined as zero CFUs growth. No preparation intended for patient use shall be compounded by an individual until the results of the initial gloved fingertip evaluation indicate that the individual can competently perform aseptic procedures except that a pharmacist may temporarily physically supervise pharmacy technicians compounding sterile preparations before the results of the evaluation have been received for no more than three days from the date of the test.(vi) Re-evaluation of all compounding personnel shall occur at least annually for compounding personnel who compound low and medium risk level preparations and every six months for compounding personnel who compound high risk level preparations. Results of gloved fingertip tests conducted immediately after compounding personnel complete a compounding procedure shall indicate no more than 3 CFUs growth, or the test shall be considered a failure, in which case, the evaluation shall be repeated until an acceptable test can be achieved (i.e., the results indicated no more than 3 CFUs growth).(M) The pharmacist-in-charge shall ensure surface sampling shall be conducted in all ISO classified areas on a periodic basis. Sampling shall be accomplished using contact plates or swabs at the conclusion of compounding. The sample area shall be gently touched with the agar surface by rolling the plate across the surface to be sampled.(5) Documentation of Training. The pharmacy shall maintain a record of the training and continuing education on each person who compounds sterile preparations. The record shall contain, at a minimum, a written record of initial and in-service training, education, and the results of written and practical testing and media-fill testing of pharmacy personnel. The record shall be maintained and available for inspection by the board and contain the following information: (A) name of the person receiving the training or completing the testing or media-fill tests;(B) date(s) of the training, testing, or media-fill challenge testing;(C) general description of the topics covered in the training or testing or of the process validated;(D) name of the person supervising the training, testing, or media-fill challenge testing; and(E) signature or initials of the person receiving the training or completing the testing or media-fill challenge testing and the pharmacist-in-charge or other pharmacist employed by the pharmacy and designated by the pharmacist-in-charge as responsible for training, testing, or media-fill challenge testing of personnel.(d) Operational Standards. (1) General Requirements. (A) Sterile preparations may be compounded: (i) upon presentation of a practitioner's prescription drug or medication order based on a valid pharmacist/patient/prescriber relationship;(ii) in anticipation of future prescription drug or medication orders based on routine, regularly observed prescribing patterns; or(iii) in reasonable quantities for office use by a practitioner and for use by a veterinarian.(B) Sterile compounding in anticipation of future prescription drug or medication orders must be based upon a history of receiving valid prescriptions issued within an established pharmacist/patient/prescriber relationship, provided that in the pharmacist's professional judgment the quantity prepared is stable for the anticipated shelf time. (i) The pharmacist's professional judgment shall be based on the criteria used to determine a beyond-use date outlined in paragraph (6)(G) of this subsection.(ii) Documentation of the criteria used to determine the stability for the anticipated shelf time must be maintained and be available for inspection.(iii) Any preparation compounded in anticipation of future prescription drug or medication orders shall be labeled. Such label shall contain: (I) name and strength of the compounded preparation or list of the active ingredients and strengths;(II) facility's lot number;(III) beyond-use date as determined by the pharmacist using appropriate documented criteria as outlined in paragraph (6)(G) of this subsection;(IV) quantity or amount in the container;(V) appropriate ancillary instructions, such as storage instructions or cautionary statements, including hazardous drug warning labels where appropriate; and(VI) device-specific instructions, where appropriate.(C) Commercially available products may be compounded for dispensing to individual patients or for office use provided the following conditions are met: (i) the commercial product is not reasonably available from normal distribution channels in a timely manner to meet individual patient's needs;(ii) the pharmacy maintains documentation that the product is not reasonably available due to a drug shortage or unavailability from the manufacturer; and(iii) the prescribing practitioner has requested that the drug be compounded as described in subparagraph (D) of this paragraph.(D) A pharmacy may not compound preparations that are essentially copies of commercially available products (e.g., the preparation is dispensed in a strength that is only slightly different from a commercially available product) unless the prescribing practitioner specifically orders the strength or dosage form and specifies why the individual patient needs the particular strength or dosage form of the preparation or why the preparation for office use is needed in the particular strength or dosage form of the preparation. The prescribing practitioner shall provide documentation of a patient specific medical need and the preparation produces a clinically significant therapeutic response (e.g., the physician requests an alternate preparation due to hypersensitivity to excipients or preservative in the FDA-approved product, or the physician requests an effective alternate dosage form) or if the drug product is not commercially available. The unavailability of such drug product must be documented prior to compounding. The methodology for documenting unavailability includes maintaining a copy of the wholesaler's notification showing back-ordered, discontinued, or out-of-stock items. This documentation must be available in hard-copy or electronic format for inspection by the board.(E) A pharmacy may enter into an agreement to compound and dispense prescription drug or medication orders for another pharmacy provided the pharmacy complies with the provisions of § 291.125 of this title (relating to Centralized Prescription Dispensing).(F) Compounding pharmacies/pharmacists may advertise and promote the fact that they provide sterile prescription compounding services, which may include specific drug preparations and classes of drugs.(G) A pharmacy may not compound veterinary preparations for use in food producing animals except in accordance with federal guidelines.(H) Compounded sterile preparations, including hazardous drugs and radiopharmaceuticals, shall be prepared only under conditions that protect the pharmacy personnel in the preparation and storage areas.(2) Microbial Contamination Risk Levels. Risk Levels for sterile compounded preparations shall be as outlined in Chapter 797, Pharmacy Compounding--Sterile Preparations of the USP/NF and as listed in this paragraph. (A) Low-risk level compounded sterile preparations. (i) Low-Risk conditions. Low-risk level compounded sterile preparations are those compounded under all of the following conditions: (I) The compounded sterile preparations are compounded with aseptic manipulations entirely within ISO Class 5 or better air quality using only sterile ingredients, products, components, and devices;(II) The compounding involves only transfer, measuring, and mixing manipulations using not more than three commercially manufactured packages of sterile products and not more than two entries into any one sterile container or package (e.g., bag, vial) of sterile product or administration container/device to prepare the compounded sterile preparation;(III) Manipulations are limited to aseptically opening ampules, penetrating disinfected stoppers on vials with sterile needles and syringes, and transferring sterile liquids in sterile syringes to sterile administration devices, package containers of other sterile products, and containers for storage and dispensing;(IV) For a low-risk level preparation, in the absence of passing a sterility test the storage periods cannot exceed the following time periods: before administration, the compounded sterile preparation is stored properly and are exposed for not more than 48 hours at controlled room temperature, for not more than 14 days if stored at a cold temperature, and for 45 days if stored in a frozen state between minus 25 degrees Celsius and minus 10 degrees Celsius. For delayed activation device systems, the storage period begins when the device is activated.(ii) Examples of Low-Risk Level Compounding. Examples of low-risk level compounding include the following: (I) Single volume transfers of sterile dosage forms from ampules, bottles, bags, and vials using sterile syringes with sterile needles, other administration devices, and other sterile containers. The solution content of ampules shall be passed through a sterile filter to remove any particles;(II) Simple aseptic measuring and transferring with not more than three packages of manufactured sterile products, including an infusion or diluent solution to compound drug admixtures and nutritional solutions.(B) Low-Risk Level compounded sterile preparations with 12-hour or less beyond-use date. Low-risk level compounded sterile preparations are those compounded pursuant to a physician's order for a specific patient under all of the following conditions: (i) The compounded sterile preparations are compounded in compounding aseptic isolator or compounding aseptic containment isolator that does not meet the requirements described in paragraph (7)(C) or (D) of this subsection (relating to Primary Engineering Control Device) or the compounded sterile preparations are compounded in laminar airflow workbench or a biological safety cabinet that cannot be located within the buffer area;(ii) The primary engineering control device shall be certified and maintain ISO Class 5 for exposure of critical sites and shall be located in a segregated compounding area restricted to sterile compounding activities that minimizes the risk of contamination of the compounded sterile preparation;(iii) The segregated compounding area shall not be in a location that has unsealed windows or doors that connect to the outdoors or high traffic flow, or that is adjacent to construction sites, warehouses, or food preparation.(iv) For a low-risk level preparation compounded as described in clauses (i) - (iii) of this subparagraph, administration of such compounded sterile preparations must commence within 12 hours of preparation or as recommended in the manufacturers' package insert, whichever is less. However, the administration of sterile radiopharmaceuticals, with documented testing of chemical stability, may be administered beyond 12 hours of preparation.(C) Medium-risk level compounded sterile preparations. (i) Medium-Risk Conditions. Medium-risk level compounded sterile preparations, are those compounded aseptically under low-risk conditions and one or more of the following conditions exists: (I) Multiple individual or small doses of sterile products are combined or pooled to prepare a compounded sterile preparation that will be administered either to multiple patients or to one patient on multiple occasions;(II) The compounding process includes complex aseptic manipulations other than the single-volume transfer;(III) The compounding process requires unusually long duration, such as that required to complete the dissolution or homogenous mixing (e.g., reconstitution of intravenous immunoglobulin or other intravenous protein products);(IV) The compounded sterile preparations do not contain broad spectrum bacteriostatic substances and they are administered over several days (e.g., an externally worn infusion device); or(V) For a medium-risk level preparation, in the absence of passing a sterility test the storage periods cannot exceed the following time periods: before administration, the compounded sterile preparations are properly stored and are exposed for not more than 30 hours at controlled room temperature, for not more than 9 days at a cold temperature, and for 45 days in solid frozen state between minus 25 degrees Celsius and minus 10 degrees Celsius.(ii) Examples of medium-risk compounding. Examples of medium-risk compounding include the following: (I) Compounding of total parenteral nutrition fluids using a manual or automated device during which there are multiple injections, detachments, and attachments of nutrient source products to the device or machine to deliver all nutritional components to a final sterile container;(II) Filling of reservoirs of injection and infusion devices with more than three sterile drug products and evacuations of air from those reservoirs before the filled device is dispensed;(III) Filling of reservoirs of injection and infusion devices with volumes of sterile drug solutions that will be administered over several days at ambient temperatures between 25 and 40 degrees Celsius (77 and 104 degrees Fahrenheit); and(IV) Transfer of volumes from multiple ampules or vials into a single, final sterile container or product.(D) High-risk level compounded sterile preparations. (i) High-risk Conditions. High-risk level compounded sterile preparations are those compounded under any of the following conditions: (I) Non-sterile ingredients, including manufactured products not intended for sterile routes of administration (e.g., oral) are incorporated or a non-sterile device is employed before terminal sterilization.(II) Any of the following are exposed to air quality worse than ISO Class 5 for more than 1 hour: (-a-) sterile contents of commercially manufactured products;(-b-) CSPs that lack effective antimicrobial preservatives; and(-c-) sterile surfaces of devices and containers for the preparation, transfer, sterilization, and packaging of CSPs;(III) Compounding personnel are improperly garbed and gloved;(IV) Non-sterile water-containing preparations are exposed no more than 6 hours before being sterilized;(V) It is assumed, and not verified by examination of labeling and documentation from suppliers or by direct determination, that the chemical purity and content strength of ingredients meet their original or compendial specifications in unopened or in opened packages of bulk ingredients;(VI) For a sterilized high-risk level preparation, in the absence of passing a sterility test, the storage periods cannot exceed the following time periods: before administration, the compounded sterile preparations are properly stored and are exposed for not more than 24 hours at controlled room temperature, for not more than 3 days at a cold temperature, and for 45 days in solid frozen state between minus 25 degrees Celsius and minus 10 degrees Celsius; or(VII) All non-sterile measuring, mixing, and purifying devices are rinsed thoroughly with pyrogen-free or depyrogenated sterile water, and then thoroughly drained or dried immediately before use for high-risk compounding. All high-risk compounded sterile solutions subjected to terminal sterilization are prefiltered by passing through a filter with a nominal pore size not larger than 1.2 micron preceding or during filling into their final containers to remove particulate matter. Sterilization of high-risk level compounded sterile preparations by filtration shall be performed with a sterile 0.2 micrometer or 0.22 micrometer nominal pore size filter entirely within an ISO Class 5 or superior air quality environment.(ii) Examples of high-risk compounding. Examples of high-risk compounding include the following. (I) Dissolving non-sterile bulk drug powders to make solutions, which will be terminally sterilized;(II) Exposing the sterile ingredients and components used to prepare and package compounded sterile preparations to room air quality worse than ISO Class 5 for more than one hour;(III) Measuring and mixing sterile ingredients in non-sterile devices before sterilization is performed; and(IV) Assuming, without appropriate evidence or direct determination, that packages of bulk ingredients contain at least 95% by weight of their active chemical moiety and have not been contaminated or adulterated between uses.(3) Immediate Use Compounded Sterile Preparations. For the purpose of emergency or immediate patient care, such situations may include cardiopulmonary resuscitation, emergency room treatment, preparation of diagnostic agents, or critical therapy where the preparation of the compounded sterile preparation under low-risk level conditions would subject the patient to additional risk due to delays in therapy. Compounded sterile preparations are exempted from the requirements described in this paragraph for low-risk level compounded sterile preparations when all of the following criteria are met: (A) Only simple aseptic measuring and transfer manipulations are performed with not more than three sterile non-hazardous commercial drug and diagnostic radiopharmaceutical drug products, including an infusion or diluent solution, from the manufacturers' original containers and not more than two entries into any one container or package of sterile infusion solution or administration container/device;(B) Unless required for the preparation, the compounding procedure occurs continuously without delays or interruptions and does not exceed 1 hour;(C) During preparation, aseptic technique is followed and, if not immediately administered, the finished compounded sterile preparation is under continuous supervision to minimize the potential for contact with nonsterile surfaces, introduction of particulate matter of biological fluids, mix-ups with other compounded sterile preparations, and direct contact with outside surfaces;(D) Administration begins not later than one hour following the completion of preparing the compounded sterile preparation;(E) When the compounded sterile preparations is not administered by the person who prepared it, or its administration is not witnessed by the person who prepared it, the compounded sterile preparation shall bear a label listing patient identification information such as name and identification number(s), the names and amounts of all ingredients, the name or initials of the person who prepared the compounded sterile preparation, and the exact 1-hour beyond-use time and date;(F) If administration has not begun within one hour following the completion of preparing the compounded sterile preparation, the compounded sterile preparation is promptly and safely discarded. Immediate use compounded sterile preparations shall not be stored for later use; and(G) Hazardous drugs shall not be prepared as immediate use compounded sterile preparations.(4) Single-dose and multiple dose containers. (A) Opened or needle punctured single-dose containers, such as bags bottles, syringes, and vials of sterile products shall be used within one hour if opened in worse than ISO Class 5 air quality. Any remaining contents must be discarded.(B) Single-dose containers, including single-dose large volume parenteral solutions and single-dose vials, exposed to ISO Class 5 or cleaner air may be used up to six hours after initial needle puncture.(C) Opened single-dose fusion sealed containers shall not be stored for any time period.(D) Multiple-dose containers may be used up to 28 days after initial needle puncture unless otherwise specified by the manufacturer.(5) Library. In addition to the library requirements of the pharmacy's specific license classification, a pharmacy shall maintain current or updated copies in hard-copy or electronic format of each of the following: (A) a reference text on injectable drug preparations, such as Handbook on Injectable Drug Products;(B) a specialty reference text appropriate for the scope of pharmacy services provided by the pharmacy, e.g., if the pharmacy prepares hazardous drugs, a reference text on the preparation of hazardous drugs;(C) the United States Pharmacopeia/National Formulary containing USP Chapter 71, Sterility Tests, USP Chapter 85, Bacterial Endotoxins Test, Pharmaceutical Compounding--Nonsterile Preparations, USP Chapter 795, USP Chapter 797, Pharmaceutical Compounding--Sterile Preparations, and USP Chapter 1163, Quality Assurance in Pharmaceutical Compounding; and(D) any additional USP/NF chapters applicable to the practice of the pharmacy (e.g., USP Chapter 800, Hazardous Drugs--Handling in Healthcare Settings, USP Chapter 823, Positron Emission Tomography Drugs for Compounding, Investigational, and Research Uses).(6) Environment. Compounding facilities shall be physically designed and environmentally controlled to minimize airborne contamination from contacting critical sites. (A) Low and Medium Risk Preparations. A pharmacy that prepares low- and medium-risk preparations shall have a clean room for the compounding of sterile preparations that is constructed to minimize the opportunities for particulate and microbial contamination. The clean room shall: (i) be clean, well lit, and of sufficient size to support sterile compounding activities;(ii) be maintained at a temperature of 20 degrees Celsius or cooler and at a humidity below 60%;(iii) be used only for the compounding of sterile preparations;(iv) be designed such that hand sanitizing and gowning occurs outside the buffer area but allows hands-free access by compounding personnel to the buffer area;(v) have non-porous and washable floors or floor covering to enable regular disinfection;(vi) be ventilated in a manner to avoid disruption from the HVAC system and room cross-drafts;(vii) have walls, ceilings, floors, fixtures, shelving, counters, and cabinets that are smooth, impervious, free from cracks and crevices (e.g., coved), non-shedding and resistant to damage by disinfectant agents;(viii) have junctures of ceilings to walls coved or caulked to avoid cracks and crevices;(ix) have drugs and supplies stored on shelving areas above the floor to permit adequate floor cleaning;(x) contain only the appropriate compounding supplies and not be used for bulk storage for supplies and materials. Objects that shed particles shall not be brought into the clean room. A Class B pharmacy may use low-linting absorbent materials in the primary engineering control device;(xi) contain an ante-area that contains a sink with hot and cold running water that enables hands-free use with a closed system of soap dispensing to minimize the risk of extrinsic contamination. A Class B pharmacy may have a sink with hot and cold running water that enables hands-free use with a closed system of soap dispensing immediately outside the ante-area if antiseptic hand cleansing is performed using a waterless alcohol-based surgical hand scrub with persistent activity following manufacturers' recommendations once inside the ante-area; and(xii) contain a buffer area. The following is applicable for the buffer area: (I) There shall be some demarcation designation that delineates the ante-area from the buffer area. The demarcation shall be such that it does not create conditions that could adversely affect the cleanliness of the area;(II) The buffer area shall be segregated from surrounding, unclassified spaces to reduce the risk of contaminants being blown, dragged, or otherwise introduced into the filtered unidirectional airflow environment, and this segregation should be continuously monitored;(III) A buffer area that is not physically separated from the ante-area shall employ the principle of displacement airflow as defined in Chapter 797, Pharmaceutical Compounding--Sterile Preparations, of the USP/NF, with limited access to personnel; and(IV) The buffer area shall not contain sources of water (i.e., sinks) or floor drains other than distilled or sterile water introduced for facilitating the use of heat block wells for radiopharmaceuticals.(B) High-risk Preparations. (i) In addition to the requirements in subparagraph (A) of this paragraph, when high-risk preparations are compounded, the primary engineering control shall be located in a buffer area that provides a physical separation, through the use of walls, doors and pass-throughs and has a minimum differential positive pressure of 0.02 to 0.05 inches water column.(ii) Presterilization procedures for high-risk level compounded sterile preparations, such as weighing and mixing, shall be completed in no worse than an ISO Class 8 environment.(C) Automated compounding device. (i) General. If automated compounding devices are used, the pharmacy shall have a method to calibrate and verify the accuracy of automated compounding devices used in aseptic processing and document the calibration and verification on a daily basis, based on the manufacturer's recommendations, and review the results at least weekly.(ii) Loading bulk drugs into automated compounding devices.(I) Automated compounding devices may be loaded with bulk drugs only by a pharmacist or by pharmacy technicians or pharmacy technician trainees under the direction and direct supervision of a pharmacist.(II) The label of an automated compounding device container shall indicate the brand name and strength of the drug; or if no brand name, then the generic name, strength, and name of the manufacturer or distributor.(III) Records of loading bulk drugs into an automated compounding device shall be maintained to show: (-a-) name of the drug, strength, and dosage form;(-b-) manufacturer or distributor;(-c-) manufacturer's lot number;(-d-) manufacturer's expiration date;(-e-) quantity added to the automated compounding device;(-g-) name, initials, or electronic signature of the person loading the automated compounding device; and(-h-) name, initials, or electronic signature of the responsible pharmacist.(IV) The automated compounding device shall not be used until a pharmacist verifies that the system is properly loaded and affixes his or her signature or electronic signature to the record specified in subclause (III) of this clause.(D) Hazardous drugs. If the preparation is hazardous, the following is also applicable: (i) Hazardous drugs shall be prepared only under conditions that protect personnel during preparation and storage;(ii) Hazardous drugs shall be stored separately from other inventory in a manner to prevent contamination and personnel exposure;(iii) All personnel involved in the compounding of hazardous drugs shall wear appropriate protective apparel, such as gowns, face masks, eye protection, hair covers, shoe covers or dedicated shoes, and appropriate gloving at all times when handling hazardous drugs, including receiving, distribution, stocking, inventorying, preparation, for administration and disposal;(iv) Appropriate safety and containment techniques for compounding hazardous drugs shall be used in conjunction with aseptic techniques required for preparing sterile preparations;(v) Disposal of hazardous waste shall comply with all applicable local, state, and federal requirements;(vi) Prepared doses of hazardous drugs must be dispensed, labeled with proper precautions inside and outside, and distributed in a manner to minimize patient contact with hazardous agents.(E) Blood-labeling procedures. When compounding activities require the manipulation of a patient's blood-derived material (e.g., radiolabeling a patient's or donor's white blood cells), the manipulations shall be performed in a ISO Class 5 biological safety cabinet located in a buffer area and shall be clearly separated from routine material-handling procedures and equipment used in preparation activities to avoid any cross-contamination. The preparations shall not require sterilization.(F) Cleaning and disinfecting the sterile compounding areas. The following cleaning and disinfecting practices and frequencies apply to direct and contiguous compounding areas, which include ISO Class 5 compounding areas for exposure of critical sites as well as buffer areas, ante-areas, and segregated compounding areas. (i) The pharmacist-in-charge is responsible for developing written standard operating procedures (SOPs) for cleaning and disinfecting the direct and contiguous compounding areas and assuring the procedures are followed.(ii) These procedures shall be conducted at the beginning of each work shift, before each batch preparation is started, when there are spills, and when surface contamination is known or suspected resulting from procedural breaches, and every 30 minutes during continuous compounding of individual compounded sterile preparations, unless a particular compounding procedure requires more than 30 minutes to complete, in which case, the direct compounding area is to be cleaned immediately after the compounding activity is completed.(iii) Before compounding is performed, all items shall be removed from the direct and contiguous compounding areas and all surfaces are cleaned by removing loose material and residue from spills, followed by an application of a residue-free disinfecting agent (e.g., IPA), which is allowed to dry before compounding begins. In a Class B pharmacy, objects used in preparing sterile radiopharmaceuticals (e.g., dose calibrator) which cannot be reasonably removed from the compounding area shall be sterilized with an application of a residue-free disinfection agent.(iv) Work surfaces in the buffer areas and ante-areas, as well as segregated compounding areas, shall be cleaned and disinfected at least daily. Dust and debris shall be removed when necessary from storage sites for compounding ingredients and supplies using a method that does not degrade the ISO Class 7 or 8 air quality.(v) Floors in the buffer area, ante-area, and segregated compounding area shall be cleaned by mopping with a cleaning and disinfecting agent at least once daily when no aseptic operations are in progress. Mopping shall be performed by trained personnel using approved agents and procedures described in the written SOPs. It is incumbent on compounding personnel to ensure that such cleaning is performed properly.(vi) In the buffer area, ante-area, and segregated compounding area, walls, ceilings, and shelving shall be cleaned and disinfected monthly. Cleaning and disinfecting agents shall be used with careful consideration of compatibilities, effectiveness, and inappropriate or toxic residues.(vii) All cleaning materials, such as wipers, sponges, and mops, shall be non-shedding, and dedicated to use in the buffer area, ante-area, and segregated compounding areas and shall not be removed from these areas except for disposal. Floor mops may be used in both the buffer area and ante-area, but only in that order. If cleaning materials are reused, procedures shall be developed that ensure that the effectiveness of the cleaning device is maintained and that repeated use does not add to the bio-burden of the area being cleaned.(viii) Supplies and equipment removed from shipping cartons must be wiped with a disinfecting agent, such as sterile IPA. After the disinfectant is sprayed or wiped on a surface to be disinfected, the disinfectant shall be allowed to dry, during which time the item shall not be used for compounding purposes. However, if sterile supplies are received in sealed pouches, the pouches may be removed as the supplies are introduced into the ISO Class 5 area without the need to disinfect the individual sterile supply items. No shipping or other external cartons may be taken into the buffer area or segregated compounding area.(ix) Storage shelving emptied of all supplies, walls, and ceilings shall be cleaned and disinfected at planned intervals, monthly, if not more frequently.(x) Cleaning must be done by personnel trained in appropriate cleaning techniques.(xi) Proper documentation and frequency of cleaning must be maintained and shall contain the following: (I) date and time of cleaning;(II) type of cleaning performed; and(III) name of individual who performed the cleaning.(G) Security requirements. The pharmacist-in-charge may authorize personnel to gain access to that area of the pharmacy containing dispensed sterile preparations, in the absence of the pharmacist, for the purpose of retrieving dispensed prescriptions to deliver to patients. If the pharmacy allows such after-hours access, the area containing the dispensed sterile preparations shall be an enclosed and lockable area separate from the area containing undispensed prescription drugs. A list of the authorized personnel having such access shall be in the pharmacy's policy and procedure manual.(H) Storage requirements and beyond-use dating. (i) Storage requirements. All drugs shall be stored at the proper temperature and conditions, as defined in the USP/NF and in § 291.15 of this title (relating to Storage of Drugs).(ii) Beyond-use dating. (I) Beyond-use dates for compounded sterile preparations shall be assigned based on professional experience, which shall include careful interpretation of appropriate information sources for the same or similar formulations.(II) Beyond-use dates for compounded sterile preparations that are prepared strictly in accordance with manufacturers' product labeling must be those specified in that labeling, or from appropriate literature sources or direct testing.(III) When assigning a beyond-use date, compounding personnel shall consult and apply drug-specific and general stability documentation and literature where available, and they should consider the nature of the drug and its degradation mechanism, the container in which it is packaged, the expected storage conditions, and the intended duration of therapy.(IV) The sterility and storage and stability beyond-use date for attached and activated container pairs of drug products for intravascular administration shall be applied as indicated by the manufacturer.(7) Primary engineering control device. The pharmacy shall prepare sterile preparations in a primary engineering control device (PEC), such as a laminar air flow hood, biological safety cabinet, compounding aseptic isolator (CAI), or compounding aseptic containment isolator (CACI) which is capable of maintaining at least ISO Class 5 conditions for 0.5 micrometer particles while compounding sterile preparations. (A) Laminar air flow hood. If the pharmacy is using a laminar air flow hood as its PEC, the laminar air flow hood shall: (i) be located in the buffer area and placed in the buffer area in a manner as to avoid conditions that could adversely affect its operation such as strong air currents from opened doors, personnel traffic, or air streams from the heating, ventilating and air condition system;(ii) be certified for operational efficiency using certification procedures, such as those outlined in the Certification Guide for Sterile Compounding Facilities (CAG-003-2006), which shall be performed by a qualified independent individual no less than every six months and whenever the device or room is relocated or altered or major service to the facility is performed;(iii) have pre-filters inspected periodically and replaced as needed, in accordance with written policies and procedures and the manufacturer's specification, and the inspection and/or replacement date documented; and(iv) be located in a buffer area that has a minimum differential positive pressure of 0.02 to 0.05 inches water column. A buffer area that is not physically separated from the ante-area shall employ the principle of displacement airflow as defined in Chapter 797, Pharmaceutical Compounding--Sterile Preparations, of the USP/NF, with limited access to personnel.(B) Biological safety cabinet. (i) If the pharmacy is using a biological safety cabinet (BSC) as its PEC for the preparation of hazardous sterile compounded preparations, the biological safety cabinet shall be a Class II or III vertical flow biological safety cabinet located in an ISO Class 7 area that is physically separated from other preparation areas. The area for preparation of sterile chemotherapeutic preparations shall: (I) have not less than 0.01 inches water column negative pressure to the adjacent positive pressure ISO Class 7 or better ante-area; and(II) have a pressure indicator that can be readily monitored for correct room pressurization.(ii) Pharmacies that prepare a low volume of hazardous drugs, are not required to comply with the provisions of clause (i) of this subparagraph if the pharmacy uses a device that provides two tiers of containment (e.g., closed-system vial transfer device within a BSC).(iii) If the pharmacy is using a biological safety cabinet as its PEC for the preparation of non-hazardous sterile compounded preparations, the biological safety cabinet shall: (I) be located in the buffer area and placed in the buffer area in a manner as to avoid conditions that could adversely affect its operation such as strong air currents from opened doors, personnel traffic, or air streams from the heating, ventilating and air condition system;(II) be certified for operational efficiency using certification procedures, such as those outlined in the Certification Guide for Sterile Compounding Facilities (CAG-003-2006), which shall be performed by a qualified independent individual no less than every six months and whenever the device or room is relocated or altered or major service to the facility is performed;(III) have pre-filters inspected periodically and replaced as needed, in accordance with written policies and procedures and the manufacturer's specification, and the inspection and/or replacement date documented; and(IV) be located in a buffer area that has a minimum differential positive pressure of 0.02 to 0.05 inches water column.(C) Compounding aseptic isolator. (i) If the pharmacy is using a compounding aseptic isolator (CAI) as its PEC, the CAI shall provide unidirectional airflow within the main processing and antechambers, and be placed in an ISO Class 7 buffer area unless the isolator meets all of the following conditions: (I) The isolator must provide isolation from the room and maintain ISO Class 5 during dynamic operating conditions including transferring ingredients, components, and devices into and out of the isolator and during preparation of compounded sterile preparations;(II) Particle counts sampled approximately 6 to 12 inches upstream of the critical exposure site must maintain ISO Class 5 levels during compounding operations;(III) The CAI must be certified for operational efficiency using certification procedures, such as those outlined in the Certification Guide for Sterile Compounding Facilities (CAG-003-2006), which shall be performed by a qualified independent individual no less than every six months and whenever the device or room is relocated or altered or major service to the facility is performed; and(IV) The pharmacy shall maintain documentation from the manufacturer that the isolator meets this standard when located in worse than ISO Class 7 environments.(ii) If the isolator meets the requirements in clause (i) of this subparagraph, the CAI may be placed in a non-ISO classified area of the pharmacy; however, the area shall be segregated from other areas of the pharmacy and shall: (I) be clean, well lit, and of sufficient size;(II) be used only for the compounding of low- and medium-risk, non-hazardous sterile preparations;(III) be located in an area of the pharmacy with non-porous and washable floors or floor covering to enable regular disinfection; and(IV) be an area in which the CAI is placed in a manner as to avoid conditions that could adversely affect its operation.(iii) In addition to the requirements specified in clauses (i) and (ii) of this subparagraph, if the CAI is used in the compounding of high-risk non-hazardous preparations, the CAI shall be placed in an area or room with at least ISO 8 quality air so that high-risk powders weighed in at least ISO-8 air quality conditions, compounding utensils for measuring and other compounding equipment are not exposed to lesser air quality prior to the completion of compounding and packaging of the high-risk preparation.(D) Compounding aseptic containment isolator.(i) If the pharmacy is using a compounding aseptic containment isolator (CACI) as its PEC for the preparation of low- and medium-risk hazardous drugs, the CACI shall be located in a separate room away from other areas of the pharmacy and shall: (I) provide at least 0.01 inches water column negative pressure compared to the other areas of the pharmacy;(II) provide unidirectional airflow within the main processing and antechambers, and be placed in an ISO Class 7 buffer area, unless the CACI meets all of the following conditions; (-a-) The isolator must provide isolation from the room and maintain ISO Class 5 during dynamic operating conditions including transferring ingredients, components, and devices into and out of the isolator and during preparation of compounded sterile preparations;(-b-) Particle counts sampled approximately 6 to 12 inches upstream of the critical exposure site must maintain ISO Class 5 levels during compounding operations;(-c-) The CACI must be certified for operational efficiency using certification procedures, such as those outlined in the Certification Guide for Sterile Compounding Facilities (CAG-003-2006), which shall be performed by a qualified independent individual no less than every six months and whenever the device or room is relocated or altered or major service to the facility is performed; and(-d-) The pharmacy shall maintain documentation from the manufacturer that the isolator meets this standard when located in worse than ISO Class 7 environments.(ii) If the CACI meets all conditions specified in clause (i) of this subparagraph, the CACI shall not be located in the same room as a CAI, but shall be located in a separate room in the pharmacy, that is not required to maintain ISO classified air. The room in which the CACI is located shall provide a minimum of 0.01 inches water column negative pressure compared with the other areas of the pharmacy and shall meet the following requirements:(I) be clean, well lit, and of sufficient size;(II) be maintained at a temperature of 20 degrees Celsius or cooler and a humidity below 60%;(III) be used only for the compounding of hazardous sterile preparations;(IV) be located in an area of the pharmacy with walls, ceilings, floors, fixtures, shelving, counters, and cabinets that are smooth, impervious, free from cracks and crevices, non-shedding and resistant to damage by disinfectant agents; and(V) have non-porous and washable floors or floor covering to enable regular disinfection.(iii) If the CACI is used in the compounding of high-risk hazardous preparations, the CACI shall be placed in an area or room with at least ISO 8 quality air so that high-risk powders, weighed in at least ISO-8 air quality conditions, are not exposed to lesser air quality prior to the completion of compounding and packaging of the high-risk preparation.(iv) Pharmacies that prepare a low volume of hazardous drugs, are not required to comply with the provisions of clauses (i) and (iii) of this subparagraph if the pharmacy uses a device that provides two tiers of containment (e.g., CACI that is located in a non-negative pressure room).(8) Additional Equipment and Supplies. Pharmacies compounding sterile preparations shall have the following equipment and supplies: (A) a calibrated system or device (i.e., thermometer) to monitor the temperature to ensure that proper storage requirements are met, if sterile preparations are stored in the refrigerator;(B) a calibrated system or device to monitor the temperature where bulk chemicals are stored;(C) a temperature-sensing mechanism suitably placed in the controlled temperature storage space to reflect accurately the true temperature;(D) if applicable, a Class A prescription balance, or analytical balance and weights. Such balance shall be properly maintained and subject to periodic inspection by the Texas State Board of Pharmacy;(E) equipment and utensils necessary for the proper compounding of sterile preparations. Such equipment and utensils used in the compounding process shall be: (i) of appropriate design, appropriate capacity, and be operated within designed operational limits;(ii) of suitable composition so that surfaces that contact components, in-process material, or drug products shall not be reactive, additive, or absorptive so as to alter the safety, identity, strength, quality, or purity of the drug preparation beyond the desired result;(iii) cleaned and sanitized immediately prior to and after each use; and(iv) routinely inspected, calibrated (if necessary), or checked to ensure proper performance;(F) appropriate disposal containers for used needles, syringes, etc., and if applicable, hazardous waste from the preparation of hazardous drugs and/or biohazardous waste;(G) appropriate packaging or delivery containers to maintain proper storage conditions for sterile preparations;(H) infusion devices, if applicable; and(I) all necessary supplies, including:(i) disposable needles, syringes, and other supplies for aseptic mixing;(ii) disinfectant cleaning solutions;(iii) sterile 70% isopropyl alcohol;(iv) sterile gloves, both for hazardous and non-hazardous drug compounding;(v) sterile alcohol-based or water-less alcohol based surgical scrub;(vi) hand washing agents with bactericidal action;(vii) disposable, lint free towels or wipes;(viii) appropriate filters and filtration equipment;(ix) hazardous spill kits, if applicable; and(x) masks, caps, coveralls or gowns with tight cuffs, shoe covers, and gloves, as applicable.(9) Labeling. (A) Prescription drug or medication orders. In addition to the labeling requirements for the pharmacy's specific license classification, the label dispensed or distributed pursuant to a prescription drug or medication order shall contain the following: (i) the generic name(s) or the official name(s) of the principal active ingredient(s) of the compounded sterile preparation;(ii) for outpatient prescription orders other than sterile radiopharmaceuticals, a statement that the compounded sterile preparation has been compounded by the pharmacy. (An auxiliary label may be used on the container to meet this requirement); and(iii) a beyond-use date. The beyond-use date shall be determined as outlined in Chapter 797, Pharmacy Compounding--Sterile Preparations of the USP/NF, and paragraph (7)(G) of this subsection;(B) Batch. If the sterile preparation is compounded in a batch, the following shall also be included on the batch label:(i) unique lot number assigned to the batch;(iii) appropriate ancillary instructions, such as storage instructions or cautionary statements, including hazardous drug warning labels where appropriate; and(iv) device-specific instructions, where appropriate.(C) Pharmacy bulk package. The label of a pharmacy bulk package shall: (i) state prominently "Pharmacy Bulk Package--Not for Direct Infusion;"(ii) contain or refer to information on proper techniques to help ensure safe use of the preparation; and(iii) bear a statement limiting the time frame in which the container may be used once it has been entered, provided it is held under the labeled storage conditions.(10) Written drug information for prescription drug orders only. Written information about the compounded preparation or its major active ingredient(s) shall be given to the patient at the time of dispensing a prescription drug order. A statement which indicates that the preparation was compounded by the pharmacy must be included in this written information. If there is no written information available, the patient shall be advised that the drug has been compounded and how to contact a pharmacist, and if appropriate, the prescriber, concerning the drug. This paragraph does not apply to the preparation of radiopharmaceuticals.(11) Pharmaceutical Care Services. In addition to the pharmaceutical care requirements for the pharmacy's specific license classification, the following requirements for sterile preparations compounded pursuant to prescription drug orders must be met. This paragraph does not apply to the preparation of radiopharmaceuticals. (A) Primary provider. There shall be a designated physician primarily responsible for the patient's medical care. There shall be a clear understanding between the physician, the patient, and the pharmacy of the responsibilities of each in the areas of the delivery of care, and the monitoring of the patient. This shall be documented in the patient medication record (PMR).(B) Patient training. The pharmacist-in-charge shall develop policies to ensure that the patient and/or patient's caregiver receives information regarding drugs and their safe and appropriate use, including instruction when applicable, regarding: (i) appropriate disposition of hazardous solutions and ancillary supplies;(ii) proper disposition of controlled substances in the home;(iii) self-administration of drugs, where appropriate;(iv) emergency procedures, including how to contact an appropriate individual in the event of problems or emergencies related to drug therapy; and(v) if the patient or patient's caregiver prepares sterile preparations in the home, the following additional information shall be provided: (I) safeguards against microbial contamination, including aseptic techniques for compounding intravenous admixtures and aseptic techniques for injecting additives to premixed intravenous solutions;(II) appropriate storage methods, including storage durations for sterile pharmaceuticals and expirations of self-mixed solutions;(III) handling and disposition of premixed and self-mixed intravenous admixtures; and(IV) proper disposition of intravenous admixture compounding supplies such as syringes, vials, ampules, and intravenous solution containers.(C) Pharmacist-patient relationship. It is imperative that a pharmacist-patient relationship be established and maintained throughout the patient's course of therapy. This shall be documented in the patient's medication record (PMR).(D) Patient monitoring. The pharmacist-in-charge shall develop policies to ensure that: (i) the patient's response to drug therapy is monitored and conveyed to the appropriate health care provider;(ii) the first dose of any new drug therapy is administered in the presence of an individual qualified to monitor for and respond to adverse drug reactions; and(iii) reports of adverse events with a compounded sterile preparation are reviewed promptly and thoroughly to correct and prevent future occurrences.(12) Drugs, components, and materials used in sterile compounding. (A) Drugs used in sterile compounding shall be a USP/NF grade substances manufactured in an FDA-registered facility.(B) If USP/NF grade substances are not available shall be of a chemical grade in one of the following categories:(i) Chemically Pure (CP);(ii) Analytical Reagent (AR);(iii) American Chemical Society (ACS); or(iv) Food Chemical Codex.(C) If a drug, component or material is not purchased from a FDA-registered facility, the pharmacist shall establish purity and stability by obtaining a Certificate of Analysis from the supplier and the pharmacist shall compare the monograph of drugs in a similar class to the Certificate of Analysis.(D) All components shall: (i) be manufactured in an FDA-registered facility; or(ii) in the professional judgment of the pharmacist, be of high quality and obtained from acceptable and reliable alternative sources; and(iii) be stored in properly labeled containers in a clean, dry area, under proper temperatures.(E) Drug preparation containers and closures shall not be reactive, additive, or absorptive so as to alter the safety, identity, strength, quality, or purity of the compounded drug preparation beyond the desired result.(F) Components, drug preparation containers, and closures shall be rotated so that the oldest stock is used first.(G) Container closure systems shall provide adequate protection against foreseeable external factors in storage and use that can cause deterioration or contamination of the compounded drug preparation.(H) A pharmacy may not compound a preparation that contains ingredients appearing on a federal Food and Drug Administration list of drug products withdrawn or removed from the market for safety reasons.(13) Compounding process. (A) Standard operating procedures (SOPs). All significant procedures performed in the compounding area shall be covered by written SOPs designed to ensure accountability, accuracy, quality, safety, and uniformity in the compounding process. At a minimum, SOPs shall be developed and implemented for: (iv) preparation evaluation;(viii) storage of compounded sterile preparations.(B) USP/NF. Any compounded formulation with an official monograph in the USP/NF shall be compounded, labeled, and packaged in conformity with the USP/NF monograph for the drug.(C) Personnel Cleansing and Garbing.(i) Any person with an apparent illness or open lesion, including rashes, sunburn, weeping sores, conjunctivitis, and active respiratory infection, that may adversely affect the safety or quality of a drug preparation being compounded shall be excluded from working in ISO Class 5, ISO Class 7, and ISO Class 8 compounding areas until the condition is remedied.(ii) Before entering the buffer area, compounding personnel must remove the following: (I) personal outer garments (e.g., bandanas, coats, hats, jackets, scarves, sweaters, vests);(II) all cosmetics, because they shed flakes and particles; and(III) all hand, wrist, and other body jewelry or piercings (e.g., earrings, lip or eyebrow piercings) that can interfere with the effectiveness of personal protective equipment (e.g., fit of gloves and cuffs of sleeves).(iii) The wearing of artificial nails or extenders is prohibited while working in the sterile compounding environment. Natural nails shall be kept neat and trimmed.(iv) Personnel shall don personal protective equipment and perform hand hygiene in an order that proceeds from the dirtiest to the cleanest activities as follows: (I) Activities considered the dirtiest include donning of dedicated shoes or shoe covers, head and facial hair covers (e.g., beard covers in addition to face masks), and face mask/eye shield. Eye shields are optional unless working with irritants like germicidal disinfecting agents or when preparing hazardous drugs.(II) After donning dedicated shoes or shoe covers, head and facial hair covers, and face masks, personnel shall perform a hand hygiene procedure by removing debris from underneath fingernails using a nail cleaner under running warm water followed by vigorous hand washing. Personnel shall begin washing arms at the hands and continue washing to elbows for at least 30 seconds with either a plain (non-antimicrobial) soap, or antimicrobial soap, and water while in the ante-area. Hands and forearms to the elbows shall be completely dried using lint-free disposable towels, an electronic hands-free hand dryer, or a HEPA filtered hand dryer.(III) After completion of hand washing, personnel shall don clean non-shedding gowns with sleeves that fit snugly around the wrists and enclosed at the neck.(IV) Once inside the buffer area or segregated compounding area, and prior to donning sterile powder-free gloves, antiseptic hand cleansing shall be performed using a waterless alcohol-based surgical hand scrub with persistent activity following manufacturers' recommendations. Hands shall be allowed to dry thoroughly before donning sterile gloves.(V) Sterile gloves that form a continuous barrier with the gown shall be the last item donned before compounding begins. Sterile gloves shall be donned using proper technique to ensure the sterility of the glove is not compromised while donning. The cuff of the sterile glove shall cover the cuff of the gown at the wrist. When preparing hazardous preparations, the compounder shall double glove or shall use single gloves ensuring that the gloves are sterile powder-free chemotherapy-rated gloves. Routine application of sterile 70% IPA shall occur throughout the compounding day and whenever non-sterile surfaces are touched.(v) When compounding personnel shall temporarily exit the buffer area during a work shift, the exterior gown, if not visibly soiled, may be removed and retained in the ante-area, to be re-donned during that same work shift only. However, shoe covers, hair and facial hair covers, face mask/eye shield, and gloves shall be replaced with new ones before re-entering the buffer area along with performing proper hand hygiene.(vi) During high-risk level compounding activities that precede terminal sterilization, such as weighing and mixing of non-sterile ingredients, compounding personnel shall be garbed and gloved the same as when performing compounding in an ISO Class 5 environment. Properly garbed and gloved compounding personnel who are exposed to air quality that is either known or suspected to be worse than ISO Class 7 shall re-garb personal protective equipment along with washing their hands properly, performing antiseptic hand cleansing with a sterile 70% IPA-based or another suitable sterile alcohol-based surgical hand scrub, and donning sterile gloves upon re-entering the ISO Class 7 buffer area.(vii) When compounding aseptic isolators or compounding aseptic containment isolators are the source of the ISO Class 5 environment, at the start of each new compounding procedure, a new pair of sterile gloves shall be donned within the CAI or CACI. In addition, the compounding personnel should follow the requirements as specified in this subparagraph, unless the isolator manufacturer can provide written documentation based on validated environmental testing that any components of personal protective equipment or cleansing are not required.(14) Quality Assurance. (A) Initial Formula Validation. Prior to routine compounding of a sterile preparation, a pharmacy shall conduct an evaluation that shows that the pharmacy is capable of compounding a preparation that is sterile and that contains the stated amount of active ingredient(s). (i) Low risk level preparations. (I) Quality assurance practices include, but are not limited to the following: (-a-) Routine disinfection and air quality testing of the direct compounding environment to minimize microbial surface contamination and maintain ISO Class 5 air quality;(-b-) Visual confirmation that compounding personnel are properly donning and wearing appropriate items and types of protective garments and goggles;(-c-) Review of all orders and packages of ingredients to ensure that the correct identity and amounts of ingredients were compounded; and(-d-) Visual inspection of compounded sterile preparations, except for sterile radiopharmaceuticals, to ensure the absence of particulate matter in solutions, the absence of leakage from vials and bags, and the accuracy and thoroughness of labeling.(II) Example of a Media-Fill Test Procedure. This, or an equivalent test, is performed at least annually by each person authorized to compound in a low-risk level under conditions that closely simulate the most challenging or stressful conditions encountered during compounding of low-risk level sterile preparations. Once begun, this test is completed without interruption within an ISO Class 5 air quality environment. Three sets of four 5-milliliter aliquots of sterile fluid culture media are transferred with the same sterile 10-milliliter syringe and vented needle combination into separate sealed, empty, sterile 30-milliliter clear vials (i.e., four 5-milliliter aliquots into each of three 30-milliliter vials). Sterile adhesive seals are aseptically affixed to the rubber closures on the three filled vials. The vials are incubated within a range of 20 - 35 degrees Celsius for a minimum of 14 days. Failure is indicated by visible turbidity in the medium on or before 14 days. The media-fill test must include a positive-control sample.(ii) Medium risk level preparations. (I) Quality assurance procedures for medium-risk level compounded sterile preparations include all those for low-risk level compounded sterile preparations, as well as a more challenging media-fill test passed annually, or more frequently.(II) Example of a Media-Fill Test Procedure. This, or an equivalent test, is performed at least annually under conditions that closely simulate the most challenging or stressful conditions encountered during compounding. This test is completed without interruption within an ISO Class 5 air quality environment. Six 100-milliliter aliquots of sterile Soybean-Casein Digest Medium are aseptically transferred by gravity through separate tubing sets into separate evacuated sterile containers. The six containers are then arranged as three pairs, and a sterile 10-milliliter syringe and 18-gauge needle combination is used to exchange two 5-milliliter aliquots of medium from one container to the other container in the pair. For example, after a 5-milliliter aliquot from the first container is added to the second container in the pair, the second container is agitated for 10 seconds, then a 5-milliliter aliquot is removed and returned to the first container in the pair. The first container is then agitated for 10 seconds, and the next 5-milliliter aliquot is transferred from it back to the second container in the pair. Following the two 5-milliliter aliquot exchanges in each pair of containers, a 5-milliliter aliquot of medium from each container is aseptically injected into a sealed, empty, sterile 10-milliliter clear vial, using a sterile 10-milliliter syringe and vented needle. Sterile adhesive seals are aseptically affixed to the rubber closures on the three filled vials. The vials are incubated within a range of 20 - 35 degrees Celsius for a minimum of 14 days. Failure is indicated by visible turbidity in the medium on or before 14 days. The media-fill test must include a positive-control sample.(iii) High risk level preparations. (I) Procedures for high-risk level compounded sterile preparations include all those for low-risk level compounded sterile preparations. In addition, a media-fill test that represents high-risk level compounding is performed twice a year by each person authorized to compound high-risk level compounded sterile preparations.(II) Example of a Media-Fill Test Procedure for Compounded Sterile Preparations Sterilized by Filtration. This test, or an equivalent test, is performed under conditions that closely simulate the most challenging or stressful conditions encountered when compounding high-risk level compounded sterile preparations. Note: Sterility tests for autoclaved compounded sterile preparations are not required unless they are prepared in batches of more than 25 units. This test is completed without interruption in the following sequence: (-a-) Dissolve 3 grams of non-sterile commercially available fluid culture media in 100 milliliters of non-bacteriostatic water to make a 3% non-sterile solution.(-b-) Draw 25 milliliters of the medium into each of three 30-milliliter sterile syringes. Transfer 5 milliliters from each syringe into separate sterile 10-milliliter vials. These vials are the positive controls to generate exponential microbial growth, which is indicated by visible turbidity upon incubation.(-c-) Under aseptic conditions and using aseptic techniques, affix a sterile 0.2-micron porosity filter unit and a 20-gauge needle to each syringe. Inject the next 10 milliliters from each syringe into three separate 10-milliliter sterile vials. Repeat the process for three more vials. Label all vials, affix sterile adhesive seals to the closure of the nine vials, and incubate them at 20 to 35 degrees Celsius for a minimum of 14 days. Inspect for microbial growth over 14 days as described in Chapter 797 Pharmaceutical Compounding--Sterile Preparations, of the USP/NF.(III) Filter Integrity Testing. Filters need to undergo testing to evaluate the integrity of filters used to sterilize high-risk preparations, such as Bubble Point Testing or comparable filter integrity testing. Such testing is not a replacement for sterility testing and shall not be interpreted as such. Such test shall be performed after a sterilization procedure on all filters used to sterilize each high-risk preparation or batch preparation and the results documented. The results should be compared with the filter manufacturer's specification for the specific filter used. If a filter fails the integrity test, the preparation or batch must be sterilized again using new unused filters.(B) Finished preparation release checks and tests.(i) All high-risk level compounded sterile preparations that are prepared in groups of more than 25 identical individual single-dose packages (such as ampules, bags, syringes, and vials), or in multiple dose vials for administration to multiple patients, or are exposed longer than 12 hours at 2 - 8 degrees Celsius and longer than six hours at warmer than 8 degrees Celsius before they are sterilized shall be tested to ensure they are sterile and do not contain excessive bacterial endotoxins as specified in Chapter 71, Sterility Tests of the USP/NF before being dispensed or administered.(ii) All compounded sterile preparations, except for sterile radiopharmaceuticals, that are intended to be solutions must be visually examined for the presence of particulate matter and not administered or dispensed when such matter is observed.(iii) The prescription drug and medication orders, written compounding procedure, preparation records, and expended materials used to make compounded sterile preparations at all contamination risk levels shall be inspected for accuracy of correct identities and amounts of ingredients, aseptic mixing and sterilization, packaging, labeling, and expected physical appearance before they are dispensed or administered.(iv) Written procedures for checking compounding accuracy shall be followed for every compounded sterile preparation during preparation, in accordance with pharmacy's policies and procedures, and immediately prior to release, including label accuracy and the accuracy of the addition of all drug products or ingredients used to prepare the finished preparation and their volumes or quantities. A pharmacist shall ensure that components used in compounding are accurately weighed, measured, or subdivided as appropriate to conform to the formula being prepared.(C) Environmental Testing. (i) Viable and nonviable environmental sampling testing. Environmental sampling shall occur, at a minimum, every six months as part of a comprehensive quality management program and under any of the following conditions: (I) as part of the commissioning and certification of new facilities and equipment;(II) following any servicing of facilities and equipment;(III) as part of the re-certification of facilities and equipment;(IV) in response to identified problems with end products or staff technique; or(V) in response to issues with compounded sterile preparations, observed compounding personnel work practices, or patient-related infections (where the compounded sterile preparation is being considered as a potential source of the infection).(ii) Total particle counts. Certification that each ISO classified area (e.g., ISO Class 5, 7, and 8), is within established guidelines shall be performed no less than every six months and whenever the equipment is relocated or the physical structure of the buffer area or ante-area has been altered. All certification records shall be maintained and reviewed to ensure that the controlled environments comply with the proper air cleanliness, room pressures, and air changes per hour. These certification records must include acceptance criteria and be made available upon inspection by the Board. Testing shall be performed by qualified operators using current, state-of-the-art equipment, with results of the following: (I) ISO Class 5 - not more than 3520 particles 0.5 micrometer and larger size per cubic meter of air;(II) ISO Class 7 - not more than 352,000 particles of 0.5 micrometer and larger size per cubic meter of air for any buffer area; and(III) ISO Class 8 - not more than 3,520,000 particles of 0.5 micrometer and larger size per cubic meter of air for any ante-area.(iii) Pressure differential monitoring. A pressure gauge or velocity meter shall be installed to monitor the pressure differential or airflow between the buffer area and the ante-area and between the ante-area and the general environment outside the compounding area. The results shall be reviewed and documented on a log at least every work shift (minimum frequency shall be at least daily) or by a continuous recording device. The pressure between the ISO Class 7 or ISO Class 8 and the general pharmacy area shall not be less than 0.02 inch water column.(iv) Sampling plan. An appropriate environmental sampling plan shall be developed for airborne viable particles based on a risk assessment of compounding activities performed. Selected sampling sites shall include locations within each ISO Class 5 environment and in the ISO Class 7 and 8 areas and in the segregated compounding areas at greatest risk of contamination. The plan shall include sample location, method of collection, frequency of sampling, volume of air sampled, and time of day as related to activity in the compounding area and action levels.(v) Viable air sampling. Evaluation of airborne microorganisms using volumetric collection methods in the controlled air environments shall be performed by properly trained individuals for all compounding risk levels. For low-, medium-, and high-risk level compounding, air sampling shall be performed at locations that are prone to contamination during compounding activities and during other activities such as staging, labeling, gowning, and cleaning. Locations shall include zones of air backwash turbulence within the laminar airflow workbench and other areas where air backwash turbulence may enter the compounding area. For low-risk level compounded sterile preparations within 12-hour or less beyond-use-date prepared in a primary engineering control that maintains an ISO Class 5, air sampling shall be performed at locations inside the ISO Class 5 environment and other areas that are in close proximity to the ISO Class 5 environment during the certification of the primary engineering control.(vi) Air sampling frequency and process. Air sampling shall be performed at least every 6 months as a part of the re-certification of facilities and equipment. A sufficient volume of air shall be sampled and the manufacturer's guidelines for use of the electronic air sampling equipment followed. At the end of the designated sampling or exposure period for air sampling activities, the microbial growth media plates are recovered and their covers secured and they are inverted and incubated at a temperature and for a time period conducive to multiplication of microorganisms. Sampling data shall be collected and reviewed on a periodic basis as a means of evaluating the overall control of the compounding environment. If an activity consistently shows elevated levels of microbial growth, competent microbiology or infection control personnel shall be consulted. A colony forming unit (cfu) count greater than 1 cfu per cubic meter of air for ISO Class 5, greater than 10 cfu per cubic meter of air for ISO Class 7, and greater than 100 cfu per cubic meter of air for ISO Class 8 or worse should prompt a re-evaluation of the adequacy of personnel work practices, cleaning procedures, operational procedures, and air filtration efficiency within the aseptic compounding location. An investigation into the source of the contamination shall be conducted. The source of the problem shall be eliminated, the affected area cleaned, and resampling performed. Counts of cfu are to be used as an approximate measure of the environmental microbial bioburden. Action levels are determined on the basis of cfu data gathered at each sampling location and trended over time. Regardless of the number of cfu identified in the pharmacy, further corrective actions will be dictated by the identification of microorganisms recovered by an appropriate credentialed laboratory of any microbial bioburden captured as a cfu using an impaction air sampler. Highly pathogenic microorganisms (e.g., gram-negative rods, coagulase positive staphylococcus, molds and yeasts) can be potentially fatal to patient receiving compounded sterile preparations and must be immediately remedied, regardless of colony forming unit count, with the assistance, if needed, of a competent microbiologist, infection control professional, or industrial hygienist.(vii) Compounding accuracy checks. Written procedures for checking compounding accuracy shall be followed for every compounded sterile preparation during preparation and immediately prior to release, including label accuracy and the accuracy of the addition of all drug products or ingredients used to prepare the finished preparation and their volumes or quantities. At each step of the compounding process, the pharmacist shall ensure that components used in compounding are accurately weighed, measured, or subdivided as appropriate to conform to the formula being prepared.(15) Quality control. (A) Quality control procedures. The pharmacy shall follow established quality control procedures to monitor the compounding environment and quality of compounded drug preparations for conformity with the quality indicators established for the preparation. When developing these procedures, pharmacy personnel shall consider the provisions of USP Chapter 71, Sterility Tests, USP Chapter 85, Bacterial Endotoxins Test, Pharmaceutical Compounding-Non-sterile Preparations, USP Chapter 795, USP Chapter 797, Pharmaceutical Compounding--Sterile Preparations, USP Chapter 800, Hazardous Drugs--Handling in Healthcare Settings, USP Chapter 823, Positron Emission Tomography Drugs for Compounding, Investigational, and Research Uses, USP Chapter 1160, Pharmaceutical Calculations in Prescription Compounding, and USP Chapter 1163, Quality Assurance in Pharmaceutical Compounding of the current USP/NF. Such procedures shall be documented and be available for inspection.(B) Verification of compounding accuracy and sterility. (i) The accuracy of identities, concentrations, amounts, and purities of ingredients in compounded sterile preparations shall be confirmed by reviewing labels on packages, observing and documenting correct measurements with approved and correctly standardized devices, and reviewing information in labeling and certificates of analysis provided by suppliers.(ii) If the correct identity, purity, strength, and sterility of ingredients and components of compounded sterile preparations cannot be confirmed such ingredients and components shall be discarded immediately. Any compounded sterile preparation that fails sterility testing following sterilization by one method (e.g., filtration) is to be discarded and not subjected to a second method of sterilization.(iii) If individual ingredients, such as bulk drug substances, are not labeled with expiration dates, when the drug substances are stable indefinitely in their commercial packages under labeled storage conditions, such ingredients may gain or lose moisture during storage and use and shall require testing to determine the correct amount to weigh for accurate content of active chemical moieties in compounded sterile preparations.(e) Records. Any testing, cleaning, procedures, or other activities required in this subsection shall be documented and such documentation shall be maintained by the pharmacy. (1) Maintenance of records. Every record required under this section must be: (A) kept by the pharmacy and be available, for at least two years for inspecting and copying by the board or its representative and to other authorized local, state, or federal law enforcement agencies; and(B) supplied by the pharmacy within 72 hours, if requested by an authorized agent of the Texas State Board of Pharmacy. If the pharmacy maintains the records in an electronic format, the requested records must be provided in an electronic format. Failure to provide the records set out in this section, either on site or within 72 hours, constitutes prima facie evidence of failure to keep and maintain records in violation of the Act.(2) Compounding records.(A) Compounding pursuant to patient specific prescription drug orders or medication orders. Compounding records for all compounded preparations shall be maintained by the pharmacy and shall include: (i) the date and time of preparation;(ii) a complete formula, including methodology and necessary equipment which includes the brand name(s) of the raw materials, or if no brand name, the generic name(s) or official name and name(s) of the manufacturer(s) or distributor of the raw materials and the quantities of each; however, if the sterile preparation is compounded according to the manufacturer's labeling instructions, then documentation of the formula is not required;(iii) written or electronic signature or initials of the pharmacist or pharmacy technician or pharmacy technician trainee performing the compounding;(iv) written or electronic signature or initials of the pharmacist responsible for supervising pharmacy technicians or pharmacy technician trainees and conducting finals checks of compounded pharmaceuticals if pharmacy technicians or pharmacy technician trainees perform the compounding function;(v) the container used and the number of units of finished preparation prepared; and(vi) a reference to the location of the following documentation which may be maintained with other records, such as quality control records: (I) the criteria used to determine the beyond-use date; and(II) documentation of performance of quality control procedures.(B) Compounding records when batch compounding or compounding in anticipation of future prescription drug or medication orders. (i) Master work sheet. A master work sheet shall be developed and approved by a pharmacist for preparations prepared in batch. Once approved, a duplicate of the master work sheet shall be used as the preparation work sheet from which each batch is prepared and on which all documentation for that batch occurs. The master work sheet shall contain at a minimum:(III) the compounding directions;(V) evaluation and testing requirements;(VI) specific equipment used during preparation; and(VII) storage requirements.(ii) Preparation work sheet. The preparation work sheet for each batch of preparations shall document the following:(I) identity of all solutions and ingredients and their corresponding amounts, concentrations, or volumes;(II) lot number for each component;(III) component manufacturer/distributor or suitable identifying number;(IV) container specifications (e.g., syringe, pump cassette);(V) unique lot or control number assigned to batch;(VI) expiration date of batch-prepared preparations;(VII) date of preparation;(VIII) name, initials, or electronic signature of the person(s) involved in the preparation;(IX) name, initials, or electronic signature of the responsible pharmacist;(X) finished preparation evaluation and testing specifications, if applicable; and(XI) comparison of actual yield to anticipated or theoretical yield, when appropriate.(f) Office Use Compounding and Distribution of Sterile Compounded Preparations (1) General. (A) A pharmacy may compound, dispense, deliver, and distribute a compounded sterile preparation as specified in Subchapter D, Texas Pharmacy Act Chapter 562.(B) A Class A-S pharmacy is not required to register or be licensed under Chapter 431, Health and Safety Code, to distribute sterile compounded preparations to a Class C or Class C-S pharmacy.(C) A Class C-S pharmacy is not required to register or be licensed under Chapter 431, Health and Safety Code, to distribute sterile compounded preparations that the Class C-S pharmacy has compounded for other Class C or Class C-S pharmacies under common ownership.(D) To compound and deliver a compounded preparation under this subsection, a pharmacy must: (i) verify the source of the raw materials to be used in a compounded drug;(ii) comply with applicable United States Pharmacopoeia guidelines, including the testing requirements, and the Health Insurance Portability and Accountability Act of 1996 (Pub. L. No. 104-191);(iii) enter into a written agreement with a practitioner for the practitioner's office use of a compounded preparation;(iv) comply with all applicable competency and accrediting standards as determined by the board; and(v) comply with the provisions of this subsection.(E) This subsection does not apply to Class B pharmacies compounding sterile radiopharmaceuticals that are furnished for departmental or physicians' use if such authorized users maintain a Texas radioactive materials license.(2) Written Agreement. A pharmacy that provides sterile compounded preparations to practitioners for office use or to another pharmacy shall enter into a written agreement with the practitioner or pharmacy. The written agreement shall: (A) address acceptable standards of practice for a compounding pharmacy and a practitioner and receiving pharmacy that enter into the agreement including a statement that the compounded drugs may only be administered to the patient and may not be dispensed to the patient or sold to any other person or entity except to a veterinarian as authorized by §563.054 of the Act;(B) require the practitioner or receiving pharmacy to include on a patient's chart, medication order or medication administration record the lot number and beyond-use date of a compounded preparation administered to a patient; and(C) describe the scope of services to be performed by the pharmacy and practitioner or receiving pharmacy, including a statement of the process for: (i) a patient to report an adverse reaction or submit a complaint; and(ii) the pharmacy to recall batches of compounded preparations.(3) Recordkeeping. (A) Maintenance of Records. (i) Records of orders and distribution of sterile compounded preparations to a practitioner for office use or to an institutional pharmacy for administration to a patient shall: (I) be kept by the pharmacy and be available, for at least two years from the date of the record, for inspecting and copying by the board or its representative and to other authorized local, state, or federal law enforcement agencies;(II) be maintained separately from the records of preparations dispensed pursuant to a prescription or medication order; and(III) be supplied by the pharmacy within 72 hours, if requested by an authorized agent of the Texas State Board of Pharmacy or its representative. If the pharmacy maintains the records in an electronic format, the requested records must be provided in an electronic format. Failure to provide the records set out in this subsection, either on site or within 72 hours for whatever reason, constitutes prima facie evidence of failure to keep and maintain records.(ii) Records may be maintained in an alternative data retention system, such as a data processing system or direct imaging system provided the data processing system is capable of producing a hard copy of the record upon the request of the board, its representative, or other authorized local, state, or federal law enforcement or regulatory agencies.(B) Orders. The pharmacy shall maintain a record of all sterile compounded preparations ordered by a practitioner for office use or by an institutional pharmacy for administration to a patient. The record shall include the following information:(ii) name, address, and phone number of the practitioner who ordered the preparation and if applicable, the name, address and phone number of the institutional pharmacy ordering the preparation; and(iii) name, strength, and quantity of the preparation ordered.(C) Distributions. The pharmacy shall maintain a record of all sterile compounded preparations distributed pursuant to an order to a practitioner for office use or by an institutional pharmacy for administration to a patient. The record shall include the following information: (i) date the preparation was compounded;(ii) date the preparation was distributed;(iii) name, strength and quantity in each container of the preparation;(iv) pharmacy's lot number;(v) quantity of containers shipped; and(vi) name, address, and phone number of the practitioner or institutional pharmacy to whom the preparation is distributed.(D) Audit Trail. (i) The pharmacy shall store the order and distribution records of preparations for all sterile compounded preparations ordered by and or distributed to a practitioner for office use or by a pharmacy licensed to compound sterile preparations for administration to a patient in such a manner as to be able to provide an audit trail for all orders and distributions of any of the following during a specified time period: (I) any strength and dosage form of a preparation (by either brand or generic name or both);(VI) any pharmacy, if applicable.(ii) The audit trail shall contain the following information:(I) date of order and date of the distribution;(II) practitioner's name, address, and name of the institutional pharmacy, if applicable;(III) name, strength and quantity of the preparation in each container of the preparation;(IV) name and quantity of each active ingredient;(V) quantity of containers distributed; and(VI) pharmacy's lot number.(4) Labeling. The pharmacy shall affix a label to the preparation containing the following information: (A) name, address, and phone number of the compounding pharmacy;(B) the statement: "For Institutional or Office Use Only--Not for Resale"; or if the preparation is distributed to a veterinarian the statement: "Compounded Preparation";(C) name and strength of the preparation or list of the active ingredients and strengths;(D) pharmacy's lot number;(E) beyond-use date as determined by the pharmacist using appropriate documented criteria;(F) quantity or amount in the container;(G) appropriate ancillary instructions, such as storage instructions or cautionary statements, including hazardous drug warning labels where appropriate; and(H) device-specific instructions, where appropriate.(g) Recall Procedures. (1) The pharmacy shall have written procedures for the recall of any compounded sterile preparation provided to a patient, to a practitioner for office use, or a pharmacy for administration. Written procedures shall include, but not be limited to the requirements as specified in paragraph (3) of this subsection.(2) The pharmacy shall immediately initiate a recall of any sterile preparation compounded by the pharmacy upon identification of a potential or confirmed harm to a patient.(3) In the event of a recall, the pharmacist-in-charge shall ensure that: (A) each practitioner, facility, and/or pharmacy to which the preparation was distributed is notified, in writing, of the recall;(B) each patient to whom the preparation was dispensed is notified, in writing, of the recall;(C) the board is notified of the recall, in writing, not later than 24 hours after the recall is issued;(D) if the preparation is distributed for office use, the Texas Department of State Health Services, Drugs and Medical Devices Group, is notified of the recall, in writing;(E) the preparation is quarantined; and(F) the pharmacy keeps a written record of the recall including all actions taken to notify all parties and steps taken to ensure corrective measures.(4) If a pharmacy fails to initiate a recall, the board may require a pharmacy to initiate a recall if there is potential for or confirmed harm to a patient.(5) A pharmacy that compounds sterile preparations shall notify the board immediately of any adverse effects reported to the pharmacy or that are known by the pharmacy to be potentially attributable to a sterile preparation compounded by the pharmacy.22 Tex. Admin. Code § 291.133
The provisions of this §291.133 adopted to be effective December 10, 2013, 38 TexReg 8869; amended to be effective September 11, 2014, 39 TexReg 7128; Amended by Texas Register, Volume 40, Number 24, June 12, 2015, TexReg 3647, eff. 6/11/2015; Amended by Texas Register, Volume 40, Number 37, September 11, 2015, TexReg 6111, eff. 9/14/2015; Amended by Texas Register, Volume 41, Number 24, June 10, 2016, TexReg 4257, eff. 6/12/2016; Amended by Texas Register, Volume 41, Number 36, September 2, 2016, TexReg 6718, eff. 9/11/2016; Amended Texas Register, Volume 42, Number 52, December 29, 2017, TexReg 7700, eff. 1/4/2018; Amended by Texas Register, Volume 43, Number 36, September 7, 2018, TexReg 5784, eff. 9/16/2018