16 Tex. Admin. Code § 12.526

Current through Reg. 49, No. 38; September 20, 2024
Section 12.526 - Use of Explosives: General Requirements
(a) This section and §§ RSA 12.527-RSA 12.530 of this title (relating to Use of Explosives) apply only to surface blasting activities incident to underground mining, including, but not limited to, initial rounds of slopes and shafts.
(b) Each operator shall comply with all applicable state and federal laws and regulations in the use of explosives.
(c) All surface blasting operations incident to underground mining shall be conducted by experienced, trained, and competent persons who understand the hazards involved. A blaster and at least one other person shall be present at the firing of a blast. Each person responsible for blasting operations shall possess a valid certification as required by §§ RSA 12.700-RSA 12.710 of this title (relating to Training, Examination, and Certification of Blasters) and:
(1) be familiar with the site-specific performance standards; and
(2) give direction and on-the-job training to persons who are not certified and who are assigned to the blasting crew to assist in the use of explosives.
(d) Blast-design requirements shall include the following:
(1) the operator shall submit to the Commission an anticipated blast design if blasting operations will be conducted within:
(A) 1,000 feet of any building used as a dwelling, public building, school, church, hospital, nursing facility, or community or institutional building outside the permit area; or
(B) 500 feet of facilities including, but not limited to, disposal wells, petroleum or gas storage facilities, active or abandoned underground mines, fluid-transmission pipelines, gas or oil-collection lines, or water and sewage lines;
(2) the blast design may be presented as part of a permit application or at a time, before the blast, approved by the Commission;
(3) the blast design shall contain sketches of the drill patterns, delay periods, and decking and shall indicate the type and amount of explosives to be used, critical dimensions, and the location and general descriptions of structures to be protected, as well as a discussion of design factors to be used, which protect the public and meet the applicable airblast, flyrock, and ground-vibration standards in § RSA 12.528 of this title (relating to Use of Explosive: Control of Adverse Effects);
(4) the blast design shall be prepared and signed by a certified blaster; and
(5) the Commission may require changes to the design submitted.

16 Tex. Admin. Code § 12.526

The provisions of this §12.526 adopted to be effective April 7, 1997, 22 TexReg 3093; amended to be effective November 4, 1997, 22 TexReg 10640.