Current through January 8, 2025
Section 0800-03-07-.12 - CAR FRAMES, ENCLOSURES, PLATFORM SIZE AND CAPACITY(1) A car frame and platform shall be of metal. Frame members shall be securely bolted and braced. With a uniformly distributed rated load the factor of safety shall not be less than 4. Solid steel toe board with a minimum height of one (1) inch shall be provided across the base of the guardwork on both sides and the lift shall be so constructed as to operate with a minimum clearance directly to the front, of at least 4 inches, measured from any point between the toe board.(2) The car shall be enclosed to the extent necessary to afford reasonable protection.(3) The platform area shall not exceed 5 square feet.(4) The rated capacity shall not be less than 300 pounds.(5) The limit of travel for any personnel elevator installed in a sewage lift station shall not be more than 50 feet.Tenn. Comp. R. & Regs. 0800-03-07-.12
Amendment filed July 24, 2000; effective November 28, 2000.Authority: T.C.A. Title 68, Chapter 121.