Section 0780-02-01-.07 - SPECIAL OCCUPANCIES
(1) All lighting fixtures in barns and other outbuildings shall be of the non-conductor type directly fastened to the outlet box. Drop lights shall not be installed in barns or other buildings, unless specifically approved for the purpose used. All convenience receptacles in outbuildings shall be at least three (3) feet above floor level. Wiring in hay mows shall be installed in conduit or otherwise protected against mechanical injury.
(2) Conductors serving swimming pools which originate at a dwelling unit service equipment or sub-panel located on the interior of the dwelling unit may be installed utilizing the appropriate wiring methods contained in Chapter 3 of the 2017 edition of the National Electrical Code. The wiring method shall comply with Article 680, 2017 edition of the National Electrical Code regarding that portion of the installation on the exterior of the dwelling unit.

Tenn. Comp. R. & Regs. 0780-02-01-.07

Original rule certified June 10, 1974. Amendment filed October 24, 1974; effective January 17, 1975. Amendment filed April 20, 1978; effective May 22, 1978. Repeal and new rule filed October 27, 1981; effective December 11, 1981. Repeal and new rule filed June 28, 1984; effective July 28, 1984. Repeal and new rule filed March 12, 1987; effective April 26, 1987. Amendment filed June 27, 1990; effective August 11, 1990. Amendment filed November 4, 1996; effective March 28, 1997. Amendment filed June 13, 1999; effective September 26, 1999. Amendment filed July 15, 2003; effective September 28, 2003. Amendment filed November 14, 2008; effective January 28, 2009. Amendments filed December 19, 2017; effective 3/19/2018.

Authority: T.C.A. §§ 68-102-113, 68-102-143, and 68-102-150.